Comparison of different methods of determination of total fluoride content in soil

The standard curve method, TISAB standard additions method, and perchloric acid standard additions method were described for the determination of total fluoride in soil using fluoride ion-selective electrode. TISAB standard additions method gave highest average recovery of 96.8% (ranging 86.9%-102.3...