Theoretical Analysis on the Leakage Characteristics of HFC-161/125/32 as an Alternative Refrigerant to HCFC-22

The effect factors that influence the leakage characteristics of HFC-161/125/32,a new alternative refrigerant for HCFC-22,were discussed.Corresponding leakage models were built and the mass ratio variations of each component under gas phase isothermal leakage and gas phase isobaric leakage cases wer...