Analysis of Methods for Extending the Life Cycle of a TP-100A Boiler

Reconditioning of the TP-100А boiler can be implemented via a number of engineering solutions, including a complete replacement of the heating surface of the primary and secondary steam superheating circuits, boiler drum replacement, pulverized coal system closing, installation of gas-tight water wa...

Full description

Saved in:
Bibliographic Details
Main Authors: Stepan Lys, Oksana Yurasova, Nadiya Lashkovska
Format: Article
Language:English
Published: Lviv Polytechnic National University 2018-06-01
Series:Energy Engineering and Control Systems
Subjects:
Online Access:https://science.lpnu.ua/jeecs/all-volumes-and-issues/volume-4-number-1-2018/analysis-methods-extending-life-cycle-tp-100a
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849727774883840000
author Stepan Lys
Oksana Yurasova
Nadiya Lashkovska
author_facet Stepan Lys
Oksana Yurasova
Nadiya Lashkovska
author_sort Stepan Lys
collection DOAJ
description Reconditioning of the TP-100А boiler can be implemented via a number of engineering solutions, including a complete replacement of the heating surface of the primary and secondary steam superheating circuits, boiler drum replacement, pulverized coal system closing, installation of gas-tight water walls; replacement of all the tanks of the water economizer, replacement of all the tanks of the tubular air heater (TAH); replacement of the check and control valves, replacement of all the steam pipelines in a boiler room. Closing the pulverized coal system will make it possible to avoid the discharge of the pulverized coal onto the electrostatic precipitators, thereby reducing the fuel consumption for electricity generation. Installation of gas-tight water walls provides for decreasing the cold air inflow into the furnace, which will have a positive effect on the output-input ratio and liquid slag output, while the replacement of all the heaters of the water economizer and air heater enables heating the feed water and, respectively, the cold air to the calculated value (before the reconstruction, the temperatures did not reach the calculated values). Replacement of the check and control valves provides for quality regulation of the main parameters of the steam, the pressure and temperature, with an increased speed of the power generating unit manoeuvring and reduced overburning of the fuel during the manoeuvring. In addition to the extended life cycle, the above listed operations will result in at least 2% increase in the output-input ratio of the boiler and significantly improve the manoeuvrability of the power generating unit.
format Article
id doaj-art-bcea8cdc966f498dba1466258b8fa86f
institution DOAJ
issn 2411-8028
2415-7287
language English
publishDate 2018-06-01
publisher Lviv Polytechnic National University
record_format Article
series Energy Engineering and Control Systems
spelling doaj-art-bcea8cdc966f498dba1466258b8fa86f2025-08-20T03:09:45ZengLviv Polytechnic National UniversityEnergy Engineering and Control Systems2411-80282415-72872018-06-01411810.23939/jeecs2018.01.001Analysis of Methods for Extending the Life Cycle of a TP-100A BoilerStepan Lys0Oksana Yurasova1Nadiya Lashkovska2Lviv Polytechnic National UniversityLviv Polytechnic National UniversityLviv Polytechnic National UniversityReconditioning of the TP-100А boiler can be implemented via a number of engineering solutions, including a complete replacement of the heating surface of the primary and secondary steam superheating circuits, boiler drum replacement, pulverized coal system closing, installation of gas-tight water walls; replacement of all the tanks of the water economizer, replacement of all the tanks of the tubular air heater (TAH); replacement of the check and control valves, replacement of all the steam pipelines in a boiler room. Closing the pulverized coal system will make it possible to avoid the discharge of the pulverized coal onto the electrostatic precipitators, thereby reducing the fuel consumption for electricity generation. Installation of gas-tight water walls provides for decreasing the cold air inflow into the furnace, which will have a positive effect on the output-input ratio and liquid slag output, while the replacement of all the heaters of the water economizer and air heater enables heating the feed water and, respectively, the cold air to the calculated value (before the reconstruction, the temperatures did not reach the calculated values). Replacement of the check and control valves provides for quality regulation of the main parameters of the steam, the pressure and temperature, with an increased speed of the power generating unit manoeuvring and reduced overburning of the fuel during the manoeuvring. In addition to the extended life cycle, the above listed operations will result in at least 2% increase in the output-input ratio of the boiler and significantly improve the manoeuvrability of the power generating unit.https://science.lpnu.ua/jeecs/all-volumes-and-issues/volume-4-number-1-2018/analysis-methods-extending-life-cycle-tp-100aboilerboiler life cycleboiler reconditioningpower generating unit manoeuvring
spellingShingle Stepan Lys
Oksana Yurasova
Nadiya Lashkovska
Analysis of Methods for Extending the Life Cycle of a TP-100A Boiler
Energy Engineering and Control Systems
boiler
boiler life cycle
boiler reconditioning
power generating unit manoeuvring
title Analysis of Methods for Extending the Life Cycle of a TP-100A Boiler
title_full Analysis of Methods for Extending the Life Cycle of a TP-100A Boiler
title_fullStr Analysis of Methods for Extending the Life Cycle of a TP-100A Boiler
title_full_unstemmed Analysis of Methods for Extending the Life Cycle of a TP-100A Boiler
title_short Analysis of Methods for Extending the Life Cycle of a TP-100A Boiler
title_sort analysis of methods for extending the life cycle of a tp 100a boiler
topic boiler
boiler life cycle
boiler reconditioning
power generating unit manoeuvring
url https://science.lpnu.ua/jeecs/all-volumes-and-issues/volume-4-number-1-2018/analysis-methods-extending-life-cycle-tp-100a
work_keys_str_mv AT stepanlys analysisofmethodsforextendingthelifecycleofatp100aboiler
AT oksanayurasova analysisofmethodsforextendingthelifecycleofatp100aboiler
AT nadiyalashkovska analysisofmethodsforextendingthelifecycleofatp100aboiler