Maternal Perception of Decreased Fetal Movement in One Twin: A Clue Leading to the Early Detection of Absent Variability due to Acute Twin-to-Twin Transfusion Syndrome

Decreased fetal movement (DFM) perceived by pregnant women sometimes indicates imminent fetal jeopardy. It is unknown whether this also holds true for twin pregnancy. A 27-year-old primiparous woman with monochorionic diamniotic (MD) pregnancy had a slight difference of amniotic fluid volume at 312/...

Full description

Saved in:
Bibliographic Details
Main Authors: Hirotada Suzuki, Tomoyuki Kuwata, Akihide Ohkuchi, Yukari Yada, Shigeki Matsubara, Mitsuaki Suzuki
Format: Article
Language:English
Published: Wiley 2013-01-01
Series:Case Reports in Obstetrics and Gynecology
Online Access:http://dx.doi.org/10.1155/2013/345808
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832556214712532992
author Hirotada Suzuki
Tomoyuki Kuwata
Akihide Ohkuchi
Yukari Yada
Shigeki Matsubara
Mitsuaki Suzuki
author_facet Hirotada Suzuki
Tomoyuki Kuwata
Akihide Ohkuchi
Yukari Yada
Shigeki Matsubara
Mitsuaki Suzuki
author_sort Hirotada Suzuki
collection DOAJ
description Decreased fetal movement (DFM) perceived by pregnant women sometimes indicates imminent fetal jeopardy. It is unknown whether this also holds true for twin pregnancy. A 27-year-old primiparous woman with monochorionic diamniotic (MD) pregnancy had a slight difference of amniotic fluid volume at 312/7 weeks of gestation. DFM only in one twin at 314/7 weeks of gestation prompted her to receive urgent consultation. Since cardiotocogram indicated absent variability of one twin, we performed Cesarean section. Male infants weighing 2060 g and 1578 g were delivered; hemoglobin was 20.7 versus 10.8 g/dL, respectively; cardiothoracic ratio was 70% versus 44%, respectively, indicating acute twin-to-twin transfusion syndrome (TTTS). The recipient infant had heart failure, which was still observed at 1 month postpartum. In conclusion, maternal perception of DFM indicated imminent fetal death or jeopardy caused by acute TTTS, suggesting that education regarding DFM for women with twin pregnancy may be clinically important.
format Article
id doaj-art-bc6aa5de7a5e435d981b063b3fde5024
institution Kabale University
issn 2090-6684
2090-6692
language English
publishDate 2013-01-01
publisher Wiley
record_format Article
series Case Reports in Obstetrics and Gynecology
spelling doaj-art-bc6aa5de7a5e435d981b063b3fde50242025-02-03T05:46:02ZengWileyCase Reports in Obstetrics and Gynecology2090-66842090-66922013-01-01201310.1155/2013/345808345808Maternal Perception of Decreased Fetal Movement in One Twin: A Clue Leading to the Early Detection of Absent Variability due to Acute Twin-to-Twin Transfusion SyndromeHirotada Suzuki0Tomoyuki Kuwata1Akihide Ohkuchi2Yukari Yada3Shigeki Matsubara4Mitsuaki Suzuki5Department of Obstetrics and Gynecology, Jichi Medical University School of Medicine, 3311-1 Yakushiji, Shimotsuke-shi, Tochigi 329-0498, JapanDepartment of Obstetrics and Gynecology, Jichi Medical University School of Medicine, 3311-1 Yakushiji, Shimotsuke-shi, Tochigi 329-0498, JapanDepartment of Obstetrics and Gynecology, Jichi Medical University School of Medicine, 3311-1 Yakushiji, Shimotsuke-shi, Tochigi 329-0498, JapanDepartment of Pediatrics, Jichi Medical University School of Medicine, 3311-1 Yakushiji, Shimotsuke-shi, Tochigi 329-0498, JapanDepartment of Obstetrics and Gynecology, Jichi Medical University School of Medicine, 3311-1 Yakushiji, Shimotsuke-shi, Tochigi 329-0498, JapanDepartment of Obstetrics and Gynecology, Jichi Medical University School of Medicine, 3311-1 Yakushiji, Shimotsuke-shi, Tochigi 329-0498, JapanDecreased fetal movement (DFM) perceived by pregnant women sometimes indicates imminent fetal jeopardy. It is unknown whether this also holds true for twin pregnancy. A 27-year-old primiparous woman with monochorionic diamniotic (MD) pregnancy had a slight difference of amniotic fluid volume at 312/7 weeks of gestation. DFM only in one twin at 314/7 weeks of gestation prompted her to receive urgent consultation. Since cardiotocogram indicated absent variability of one twin, we performed Cesarean section. Male infants weighing 2060 g and 1578 g were delivered; hemoglobin was 20.7 versus 10.8 g/dL, respectively; cardiothoracic ratio was 70% versus 44%, respectively, indicating acute twin-to-twin transfusion syndrome (TTTS). The recipient infant had heart failure, which was still observed at 1 month postpartum. In conclusion, maternal perception of DFM indicated imminent fetal death or jeopardy caused by acute TTTS, suggesting that education regarding DFM for women with twin pregnancy may be clinically important.http://dx.doi.org/10.1155/2013/345808
spellingShingle Hirotada Suzuki
Tomoyuki Kuwata
Akihide Ohkuchi
Yukari Yada
Shigeki Matsubara
Mitsuaki Suzuki
Maternal Perception of Decreased Fetal Movement in One Twin: A Clue Leading to the Early Detection of Absent Variability due to Acute Twin-to-Twin Transfusion Syndrome
Case Reports in Obstetrics and Gynecology
title Maternal Perception of Decreased Fetal Movement in One Twin: A Clue Leading to the Early Detection of Absent Variability due to Acute Twin-to-Twin Transfusion Syndrome
title_full Maternal Perception of Decreased Fetal Movement in One Twin: A Clue Leading to the Early Detection of Absent Variability due to Acute Twin-to-Twin Transfusion Syndrome
title_fullStr Maternal Perception of Decreased Fetal Movement in One Twin: A Clue Leading to the Early Detection of Absent Variability due to Acute Twin-to-Twin Transfusion Syndrome
title_full_unstemmed Maternal Perception of Decreased Fetal Movement in One Twin: A Clue Leading to the Early Detection of Absent Variability due to Acute Twin-to-Twin Transfusion Syndrome
title_short Maternal Perception of Decreased Fetal Movement in One Twin: A Clue Leading to the Early Detection of Absent Variability due to Acute Twin-to-Twin Transfusion Syndrome
title_sort maternal perception of decreased fetal movement in one twin a clue leading to the early detection of absent variability due to acute twin to twin transfusion syndrome
url http://dx.doi.org/10.1155/2013/345808
work_keys_str_mv AT hirotadasuzuki maternalperceptionofdecreasedfetalmovementinonetwinaclueleadingtotheearlydetectionofabsentvariabilityduetoacutetwintotwintransfusionsyndrome
AT tomoyukikuwata maternalperceptionofdecreasedfetalmovementinonetwinaclueleadingtotheearlydetectionofabsentvariabilityduetoacutetwintotwintransfusionsyndrome
AT akihideohkuchi maternalperceptionofdecreasedfetalmovementinonetwinaclueleadingtotheearlydetectionofabsentvariabilityduetoacutetwintotwintransfusionsyndrome
AT yukariyada maternalperceptionofdecreasedfetalmovementinonetwinaclueleadingtotheearlydetectionofabsentvariabilityduetoacutetwintotwintransfusionsyndrome
AT shigekimatsubara maternalperceptionofdecreasedfetalmovementinonetwinaclueleadingtotheearlydetectionofabsentvariabilityduetoacutetwintotwintransfusionsyndrome
AT mitsuakisuzuki maternalperceptionofdecreasedfetalmovementinonetwinaclueleadingtotheearlydetectionofabsentvariabilityduetoacutetwintotwintransfusionsyndrome