Zipper repair of 3 cm iatrogenic colonic perforation with dual‐channel endoscope and twin grasper‐assisted titanium clip
Abstract A 53‐year‐old man undergoing painless colonoscopy for long‐term diarrhea. After colonoscopy withdrawing to the sigmoid colon, a local perforation was found, about 3 cm in size, oval in shape. We used a two‐channel endoscope and grip to pull the edges of the intestinal wall on both sides of...