A Study on Internal Explosion Testing of the “Rigid-Flexible-Rigid” Three-Layer Sealed Structure

Multilayered combination of protective structures is an important means of effectively weakening the explosive shockwave. On this basis, a “rigid-flexible-rigid” three-layer sealed structure was proposed in this paper and two models for the sealed structure were designed. Meanwhile, internal explosi...

Full description

Saved in:
Bibliographic Details
Main Authors: Y. L. Xue, D. G. Tang, Z. Z. Li, L. Z. Shao, Z. Liao, W. X. Chen, R. L. Zhen
Format: Article
Language:English
Published: Wiley 2018-01-01
Series:Shock and Vibration
Online Access:http://dx.doi.org/10.1155/2018/1909872
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Multilayered combination of protective structures is an important means of effectively weakening the explosive shockwave. On this basis, a “rigid-flexible-rigid” three-layer sealed structure was proposed in this paper and two models for the sealed structure were designed. Meanwhile, internal explosion tests of the two models were conducted. One model used foam concrete as the energy absorbing material and the other used dense sand. The comparisons between the test results and the computed results obtained from the formulae were made, and the test results agreed well with the computed results. Test results showed that both models had favorable energy-dissipating capacity, and the model that used foam concrete as the energy absorbing material had a superior energy-dissipating capacity.
ISSN:1070-9622
1875-9203