A Flexible Quantification Method for Buildings’ Air Conditioning Based on the Light and Heat Transfer Coefficients: A Case Study of a Shanghai Office Building
The massive integration of renewable electricity places significant regulatory pressure on urban power grids. This has also promoted the development of virtual power plant technology. The air conditioning systems of public buildings, as one of the main cores of virtual power plants, have flexible re...
Saved in:
| Main Authors: | , , , , |
|---|---|
| Format: | Article |
| Language: | English |
| Published: |
MDPI AG
2025-03-01
|
| Series: | Energies |
| Subjects: | |
| Online Access: | https://www.mdpi.com/1996-1073/18/6/1311 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| _version_ | 1849341636229726208 |
|---|---|
| author | Dan Yu Tingting Xu Yunxia Jiang Qin Li Fanyue Qian |
| author_facet | Dan Yu Tingting Xu Yunxia Jiang Qin Li Fanyue Qian |
| author_sort | Dan Yu |
| collection | DOAJ |
| description | The massive integration of renewable electricity places significant regulatory pressure on urban power grids. This has also promoted the development of virtual power plant technology. The air conditioning systems of public buildings, as one of the main cores of virtual power plants, have flexible regulation capability that is difficult to quantify accurately, leading to slow development in practical engineering applications. This study proposes quantifying the flexible regulation capability of public building air conditioning systems based on heat and light transfer coefficient (HTC and LTC). Taking a public building in Shanghai as an example, this study combines 3D modeling and simulation and sliding window and correlation analysis techniques to investigate changes in influencing factors under different time periods, levels of insulation performance, and window-to-wall ratios. Drawing an analogy with energy storage batteries, two quantification indicators, response time (RT) and response energy loss (RL), are proposed and combined with heat and light transmission systems for nonlinear fitting. Finally, a sensitivity analysis of the impact of external environment and building performance is conducted. The results of sliding window and correlation analysis show that surface irradiance has the highest correlation with air conditioning energy consumption (over 0.8). However, through linear and nonlinear fitting, it was found that HTC can better characterize the two key indicators of RT and RL in air conditioning flexible adjustment, with fitting degrees (R<sup>2</sup>) of 80% and 72%, respectively. The results obtained from this study can provide a quantitative reference for quantification and response control research into the flexible regulation capability of public building air conditioning systems. |
| format | Article |
| id | doaj-art-9c7cf85d56ea4d5e95eafd79fc2bbbcb |
| institution | Kabale University |
| issn | 1996-1073 |
| language | English |
| publishDate | 2025-03-01 |
| publisher | MDPI AG |
| record_format | Article |
| series | Energies |
| spelling | doaj-art-9c7cf85d56ea4d5e95eafd79fc2bbbcb2025-08-20T03:43:36ZengMDPI AGEnergies1996-10732025-03-01186131110.3390/en18061311A Flexible Quantification Method for Buildings’ Air Conditioning Based on the Light and Heat Transfer Coefficients: A Case Study of a Shanghai Office BuildingDan Yu0Tingting Xu1Yunxia Jiang2Qin Li3Fanyue Qian4School of Engineering, Sanda University, Shanghai 201209, ChinaCollege of Mechanical and Energy Engineering, Tongji University, Shanghai 200092, ChinaSchool of Engineering, Sanda University, Shanghai 201209, ChinaSchool of Engineering, Sanda University, Shanghai 201209, ChinaEnergy and Environment Engineering Institute, Shanghai University of Electric Power, Shanghai 200090, ChinaThe massive integration of renewable electricity places significant regulatory pressure on urban power grids. This has also promoted the development of virtual power plant technology. The air conditioning systems of public buildings, as one of the main cores of virtual power plants, have flexible regulation capability that is difficult to quantify accurately, leading to slow development in practical engineering applications. This study proposes quantifying the flexible regulation capability of public building air conditioning systems based on heat and light transfer coefficient (HTC and LTC). Taking a public building in Shanghai as an example, this study combines 3D modeling and simulation and sliding window and correlation analysis techniques to investigate changes in influencing factors under different time periods, levels of insulation performance, and window-to-wall ratios. Drawing an analogy with energy storage batteries, two quantification indicators, response time (RT) and response energy loss (RL), are proposed and combined with heat and light transmission systems for nonlinear fitting. Finally, a sensitivity analysis of the impact of external environment and building performance is conducted. The results of sliding window and correlation analysis show that surface irradiance has the highest correlation with air conditioning energy consumption (over 0.8). However, through linear and nonlinear fitting, it was found that HTC can better characterize the two key indicators of RT and RL in air conditioning flexible adjustment, with fitting degrees (R<sup>2</sup>) of 80% and 72%, respectively. The results obtained from this study can provide a quantitative reference for quantification and response control research into the flexible regulation capability of public building air conditioning systems.https://www.mdpi.com/1996-1073/18/6/1311building air conditioning systemflexible regulation capabilityquantitative representationheat transfer systemsliding window |
| spellingShingle | Dan Yu Tingting Xu Yunxia Jiang Qin Li Fanyue Qian A Flexible Quantification Method for Buildings’ Air Conditioning Based on the Light and Heat Transfer Coefficients: A Case Study of a Shanghai Office Building Energies building air conditioning system flexible regulation capability quantitative representation heat transfer system sliding window |
| title | A Flexible Quantification Method for Buildings’ Air Conditioning Based on the Light and Heat Transfer Coefficients: A Case Study of a Shanghai Office Building |
| title_full | A Flexible Quantification Method for Buildings’ Air Conditioning Based on the Light and Heat Transfer Coefficients: A Case Study of a Shanghai Office Building |
| title_fullStr | A Flexible Quantification Method for Buildings’ Air Conditioning Based on the Light and Heat Transfer Coefficients: A Case Study of a Shanghai Office Building |
| title_full_unstemmed | A Flexible Quantification Method for Buildings’ Air Conditioning Based on the Light and Heat Transfer Coefficients: A Case Study of a Shanghai Office Building |
| title_short | A Flexible Quantification Method for Buildings’ Air Conditioning Based on the Light and Heat Transfer Coefficients: A Case Study of a Shanghai Office Building |
| title_sort | flexible quantification method for buildings air conditioning based on the light and heat transfer coefficients a case study of a shanghai office building |
| topic | building air conditioning system flexible regulation capability quantitative representation heat transfer system sliding window |
| url | https://www.mdpi.com/1996-1073/18/6/1311 |
| work_keys_str_mv | AT danyu aflexiblequantificationmethodforbuildingsairconditioningbasedonthelightandheattransfercoefficientsacasestudyofashanghaiofficebuilding AT tingtingxu aflexiblequantificationmethodforbuildingsairconditioningbasedonthelightandheattransfercoefficientsacasestudyofashanghaiofficebuilding AT yunxiajiang aflexiblequantificationmethodforbuildingsairconditioningbasedonthelightandheattransfercoefficientsacasestudyofashanghaiofficebuilding AT qinli aflexiblequantificationmethodforbuildingsairconditioningbasedonthelightandheattransfercoefficientsacasestudyofashanghaiofficebuilding AT fanyueqian aflexiblequantificationmethodforbuildingsairconditioningbasedonthelightandheattransfercoefficientsacasestudyofashanghaiofficebuilding AT danyu flexiblequantificationmethodforbuildingsairconditioningbasedonthelightandheattransfercoefficientsacasestudyofashanghaiofficebuilding AT tingtingxu flexiblequantificationmethodforbuildingsairconditioningbasedonthelightandheattransfercoefficientsacasestudyofashanghaiofficebuilding AT yunxiajiang flexiblequantificationmethodforbuildingsairconditioningbasedonthelightandheattransfercoefficientsacasestudyofashanghaiofficebuilding AT qinli flexiblequantificationmethodforbuildingsairconditioningbasedonthelightandheattransfercoefficientsacasestudyofashanghaiofficebuilding AT fanyueqian flexiblequantificationmethodforbuildingsairconditioningbasedonthelightandheattransfercoefficientsacasestudyofashanghaiofficebuilding |