Application of PAUT Technology in Testing Radial Gate on the Right Bank of the Datengxia Water Conservancy Project

Under the background of a tight construction schedule and heavy tasks,this paper applies PAUT technology to the radial gate on the right bank of the Datengxia water conservancy project,so as to ensure the welding quality of the radial gate of the Datengxia water conservancy project.In addition,the c...

Full description

Saved in:
Bibliographic Details
Main Authors: XIE Ji'an, PAN Hong, HE Qilian, CHEN Zhuangsheng, LIU Tao
Format: Article
Language:zho
Published: Editorial Office of Pearl River 2022-01-01
Series:Renmin Zhujiang
Subjects:
Online Access:http://www.renminzhujiang.cn/thesisDetails#10.3969/j.issn.1001-9235.2022.12.001
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Under the background of a tight construction schedule and heavy tasks,this paper applies PAUT technology to the radial gate on the right bank of the Datengxia water conservancy project,so as to ensure the welding quality of the radial gate of the Datengxia water conservancy project.In addition,the conventional ultrasonic testing technology and PAUT technology are used and compared in terms of the welds in the main parts of the gate.The experimental comparison results show that PAUT technology is superior to conventional ultrasonic testing technology in defect detection rate and graphic imaging.It is proved that the defect detection rate of PAUT technology is better than that of the conventional ultrasonic wave,and log files permanently saved can be obtained.