Leadless pacemaker implantation in a patient with congenital azygos continuation of the inferior vena cava
Abstract Abstract In case of venous route abnormality during a leadless pacemaker (LP) implantation, it can be challenging if we still performed via the predesigned femoral vein. We report a patient with normal preoperative laboratory and image results, but azygos continuation of the inferior vena c...