Estimating the Uplift Bearing Capacity of Belled Piers Adjacent to Sloping Ground by Numerical Modeling Based on Field Tests
In order to evaluate the uplift bearing capacity of belled piers beside slopes, a series of numerical simulations are carried out based on field tests data. First, a number of uplift loading tests of full-scale belled piers are carried out on the project site of transmission line in Anhui Province,...
Saved in:
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Wiley
2020-01-01
|
Series: | Advances in Civil Engineering |
Online Access: | http://dx.doi.org/10.1155/2020/1647197 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1832562884710760448 |
---|---|
author | Yangchun Han Jiulong Cheng Weifeng Zheng Shijun Ding |
author_facet | Yangchun Han Jiulong Cheng Weifeng Zheng Shijun Ding |
author_sort | Yangchun Han |
collection | DOAJ |
description | In order to evaluate the uplift bearing capacity of belled piers beside slopes, a series of numerical simulations are carried out based on field tests data. First, a number of uplift loading tests of full-scale belled piers are carried out on the project site of transmission line in Anhui Province, China. Second, a slope-foundation model for numerical modeling is proposed and calibrated based on field tests data. The behavior of belled piers adjacent to slopes subject to uplift load is studied by numerical modeling. The impact of three parameters, including distance (a) from the belled pier to the crest of the slope, slope angle (β), and embedment depth (h) of the belled pier, has been investigated on the uplift capacity of the belled pier. Based on the simulation results, an attenuation coefficient (ω) is put forward for evaluating the reduction of uplift bearing capacity of the belled pier. The results show that the coefficient ω is negatively correlated with distance a and depth h, and the influence of distance a is greater than that of depth h according to the results of variance analysis, but the difference is not significant by F test. Moreover, the empirical equation between attenuation coefficient ω and three key factors a, β, and h had been presented by a series of fitting. |
format | Article |
id | doaj-art-7ef959496cb2499f8573c8b5c3b3bbea |
institution | Kabale University |
issn | 1687-8086 1687-8094 |
language | English |
publishDate | 2020-01-01 |
publisher | Wiley |
record_format | Article |
series | Advances in Civil Engineering |
spelling | doaj-art-7ef959496cb2499f8573c8b5c3b3bbea2025-02-03T01:21:34ZengWileyAdvances in Civil Engineering1687-80861687-80942020-01-01202010.1155/2020/16471971647197Estimating the Uplift Bearing Capacity of Belled Piers Adjacent to Sloping Ground by Numerical Modeling Based on Field TestsYangchun Han0Jiulong Cheng1Weifeng Zheng2Shijun Ding3College of Geoscience and Surveying Engineering, China University of Mining and Technology (Beijing), Beijing 100083, ChinaCollege of Geoscience and Surveying Engineering, China University of Mining and Technology (Beijing), Beijing 100083, ChinaLiangxiang Branch Institute, China Electric Power Research Institute, Beijing 102401, ChinaLiangxiang Branch Institute, China Electric Power Research Institute, Beijing 102401, ChinaIn order to evaluate the uplift bearing capacity of belled piers beside slopes, a series of numerical simulations are carried out based on field tests data. First, a number of uplift loading tests of full-scale belled piers are carried out on the project site of transmission line in Anhui Province, China. Second, a slope-foundation model for numerical modeling is proposed and calibrated based on field tests data. The behavior of belled piers adjacent to slopes subject to uplift load is studied by numerical modeling. The impact of three parameters, including distance (a) from the belled pier to the crest of the slope, slope angle (β), and embedment depth (h) of the belled pier, has been investigated on the uplift capacity of the belled pier. Based on the simulation results, an attenuation coefficient (ω) is put forward for evaluating the reduction of uplift bearing capacity of the belled pier. The results show that the coefficient ω is negatively correlated with distance a and depth h, and the influence of distance a is greater than that of depth h according to the results of variance analysis, but the difference is not significant by F test. Moreover, the empirical equation between attenuation coefficient ω and three key factors a, β, and h had been presented by a series of fitting.http://dx.doi.org/10.1155/2020/1647197 |
spellingShingle | Yangchun Han Jiulong Cheng Weifeng Zheng Shijun Ding Estimating the Uplift Bearing Capacity of Belled Piers Adjacent to Sloping Ground by Numerical Modeling Based on Field Tests Advances in Civil Engineering |
title | Estimating the Uplift Bearing Capacity of Belled Piers Adjacent to Sloping Ground by Numerical Modeling Based on Field Tests |
title_full | Estimating the Uplift Bearing Capacity of Belled Piers Adjacent to Sloping Ground by Numerical Modeling Based on Field Tests |
title_fullStr | Estimating the Uplift Bearing Capacity of Belled Piers Adjacent to Sloping Ground by Numerical Modeling Based on Field Tests |
title_full_unstemmed | Estimating the Uplift Bearing Capacity of Belled Piers Adjacent to Sloping Ground by Numerical Modeling Based on Field Tests |
title_short | Estimating the Uplift Bearing Capacity of Belled Piers Adjacent to Sloping Ground by Numerical Modeling Based on Field Tests |
title_sort | estimating the uplift bearing capacity of belled piers adjacent to sloping ground by numerical modeling based on field tests |
url | http://dx.doi.org/10.1155/2020/1647197 |
work_keys_str_mv | AT yangchunhan estimatingtheupliftbearingcapacityofbelledpiersadjacenttoslopinggroundbynumericalmodelingbasedonfieldtests AT jiulongcheng estimatingtheupliftbearingcapacityofbelledpiersadjacenttoslopinggroundbynumericalmodelingbasedonfieldtests AT weifengzheng estimatingtheupliftbearingcapacityofbelledpiersadjacenttoslopinggroundbynumericalmodelingbasedonfieldtests AT shijunding estimatingtheupliftbearingcapacityofbelledpiersadjacenttoslopinggroundbynumericalmodelingbasedonfieldtests |