Determination of Selected Polycyclic Aromatic Compounds in Particulate Matter Samples with Low Mass Loading: An Approach to Test Method Accuracy

A miniaturized analytical procedure to determine selected polycyclic aromatic compounds (PACs) in low mass loadings (<10 mg) of particulate matter (PM) is evaluated. The proposed method is based on a simple sonication/agitation method using small amounts of solvent for extraction. The use of a re...

Full description

Saved in:
Bibliographic Details
Main Authors: Susana García-Alonso, Rosa María Pérez-Pastor, Víctor Archilla-Prat, David Sanz-Rivera, Enrique Rojas-García, Gaizka Aragón-Urrengoetxea, Jesús Javier Rodríguez-Maroto
Format: Article
Language:English
Published: Wiley 2017-01-01
Series:Journal of Chemistry
Online Access:http://dx.doi.org/10.1155/2017/3517457
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832551801264537600
author Susana García-Alonso
Rosa María Pérez-Pastor
Víctor Archilla-Prat
David Sanz-Rivera
Enrique Rojas-García
Gaizka Aragón-Urrengoetxea
Jesús Javier Rodríguez-Maroto
author_facet Susana García-Alonso
Rosa María Pérez-Pastor
Víctor Archilla-Prat
David Sanz-Rivera
Enrique Rojas-García
Gaizka Aragón-Urrengoetxea
Jesús Javier Rodríguez-Maroto
author_sort Susana García-Alonso
collection DOAJ
description A miniaturized analytical procedure to determine selected polycyclic aromatic compounds (PACs) in low mass loadings (<10 mg) of particulate matter (PM) is evaluated. The proposed method is based on a simple sonication/agitation method using small amounts of solvent for extraction. The use of a reduced sample size of particulate matter is often limiting for allowing the quantification of analytes. This also leads to the need for changing analytical procedures and evaluating its performance. The trueness and precision of the proposed method were tested using ambient air samples. Analytical results from the proposed method were compared with those of pressurized liquid and microwave extractions. Selected PACs (polycyclic aromatic hydrocarbons (PAHs) and nitro polycyclic aromatic hydrocarbons (NPAHs)) were determined by liquid chromatography with fluorescence detection (HPLC/FD). Taking results from pressurized liquid extractions as reference values, recovery rates of sonication/agitation method were over 80% for the most abundant PAHs. Recovery rates of selected NPAHs were lower. Enhanced rates were obtained when methanol was used as a modifier. Intermediate precision was estimated by data comparison from two mathematical approaches: normalized difference data and pooled relative deviations. Intermediate precision was in the range of 10–20%. The effectiveness of the proposed method was evaluated in PM aerosol samples collected with very low mass loadings (<0.2 mg) during characterization studies from turbofan engine exhausts.
format Article
id doaj-art-5744e23ff07944a09d70bd6b7f3f311d
institution Kabale University
issn 2090-9063
2090-9071
language English
publishDate 2017-01-01
publisher Wiley
record_format Article
series Journal of Chemistry
spelling doaj-art-5744e23ff07944a09d70bd6b7f3f311d2025-02-03T06:00:29ZengWileyJournal of Chemistry2090-90632090-90712017-01-01201710.1155/2017/35174573517457Determination of Selected Polycyclic Aromatic Compounds in Particulate Matter Samples with Low Mass Loading: An Approach to Test Method AccuracySusana García-Alonso0Rosa María Pérez-Pastor1Víctor Archilla-Prat2David Sanz-Rivera3Enrique Rojas-García4Gaizka Aragón-Urrengoetxea5Jesús Javier Rodríguez-Maroto6CIEMAT, Technology Department, Madrid, SpainCIEMAT, Technology Department, Madrid, SpainINTA, Madrid, SpainCIEMAT, Environment Department, Madrid, SpainCIEMAT, Environment Department, Madrid, SpainINTA, Madrid, SpainCIEMAT, Environment Department, Madrid, SpainA miniaturized analytical procedure to determine selected polycyclic aromatic compounds (PACs) in low mass loadings (<10 mg) of particulate matter (PM) is evaluated. The proposed method is based on a simple sonication/agitation method using small amounts of solvent for extraction. The use of a reduced sample size of particulate matter is often limiting for allowing the quantification of analytes. This also leads to the need for changing analytical procedures and evaluating its performance. The trueness and precision of the proposed method were tested using ambient air samples. Analytical results from the proposed method were compared with those of pressurized liquid and microwave extractions. Selected PACs (polycyclic aromatic hydrocarbons (PAHs) and nitro polycyclic aromatic hydrocarbons (NPAHs)) were determined by liquid chromatography with fluorescence detection (HPLC/FD). Taking results from pressurized liquid extractions as reference values, recovery rates of sonication/agitation method were over 80% for the most abundant PAHs. Recovery rates of selected NPAHs were lower. Enhanced rates were obtained when methanol was used as a modifier. Intermediate precision was estimated by data comparison from two mathematical approaches: normalized difference data and pooled relative deviations. Intermediate precision was in the range of 10–20%. The effectiveness of the proposed method was evaluated in PM aerosol samples collected with very low mass loadings (<0.2 mg) during characterization studies from turbofan engine exhausts.http://dx.doi.org/10.1155/2017/3517457
spellingShingle Susana García-Alonso
Rosa María Pérez-Pastor
Víctor Archilla-Prat
David Sanz-Rivera
Enrique Rojas-García
Gaizka Aragón-Urrengoetxea
Jesús Javier Rodríguez-Maroto
Determination of Selected Polycyclic Aromatic Compounds in Particulate Matter Samples with Low Mass Loading: An Approach to Test Method Accuracy
Journal of Chemistry
title Determination of Selected Polycyclic Aromatic Compounds in Particulate Matter Samples with Low Mass Loading: An Approach to Test Method Accuracy
title_full Determination of Selected Polycyclic Aromatic Compounds in Particulate Matter Samples with Low Mass Loading: An Approach to Test Method Accuracy
title_fullStr Determination of Selected Polycyclic Aromatic Compounds in Particulate Matter Samples with Low Mass Loading: An Approach to Test Method Accuracy
title_full_unstemmed Determination of Selected Polycyclic Aromatic Compounds in Particulate Matter Samples with Low Mass Loading: An Approach to Test Method Accuracy
title_short Determination of Selected Polycyclic Aromatic Compounds in Particulate Matter Samples with Low Mass Loading: An Approach to Test Method Accuracy
title_sort determination of selected polycyclic aromatic compounds in particulate matter samples with low mass loading an approach to test method accuracy
url http://dx.doi.org/10.1155/2017/3517457
work_keys_str_mv AT susanagarciaalonso determinationofselectedpolycyclicaromaticcompoundsinparticulatemattersampleswithlowmassloadinganapproachtotestmethodaccuracy
AT rosamariaperezpastor determinationofselectedpolycyclicaromaticcompoundsinparticulatemattersampleswithlowmassloadinganapproachtotestmethodaccuracy
AT victorarchillaprat determinationofselectedpolycyclicaromaticcompoundsinparticulatemattersampleswithlowmassloadinganapproachtotestmethodaccuracy
AT davidsanzrivera determinationofselectedpolycyclicaromaticcompoundsinparticulatemattersampleswithlowmassloadinganapproachtotestmethodaccuracy
AT enriquerojasgarcia determinationofselectedpolycyclicaromaticcompoundsinparticulatemattersampleswithlowmassloadinganapproachtotestmethodaccuracy
AT gaizkaaragonurrengoetxea determinationofselectedpolycyclicaromaticcompoundsinparticulatemattersampleswithlowmassloadinganapproachtotestmethodaccuracy
AT jesusjavierrodriguezmaroto determinationofselectedpolycyclicaromaticcompoundsinparticulatemattersampleswithlowmassloadinganapproachtotestmethodaccuracy