Effect of Autoclave Sterilization on the Number of Uses and Resistance to Cyclic Fatigue of WaveOne Gold and Four Replica-Like Endodontic Instruments
This study aimed to evaluate the effect of autoclave sterilization on the integrity and instruments’ fracture number after multiple uses and cyclic fatigue of the original WaveOne Gold (Dentsply Sirona Endodontics) compared to four replica-like instruments (TF4-Gold, Roll-Wave-Gold, W-File, and Micr...
Saved in:
Main Authors: | , , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Wiley
2024-01-01
|
Series: | International Journal of Dentistry |
Online Access: | http://dx.doi.org/10.1155/2024/6628146 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1832546194186829824 |
---|---|
author | Gustavo Ragozzini Amjad Abu Hasna Fernando Antonio Siano dos Reis Felipe Bernardo de Moura Tiago Moreira Bastos Campos Carlos Eduardo Silveira Bueno Cláudio Antonio Talge Carvalho Alexandre Sigrist de Martin |
author_facet | Gustavo Ragozzini Amjad Abu Hasna Fernando Antonio Siano dos Reis Felipe Bernardo de Moura Tiago Moreira Bastos Campos Carlos Eduardo Silveira Bueno Cláudio Antonio Talge Carvalho Alexandre Sigrist de Martin |
author_sort | Gustavo Ragozzini |
collection | DOAJ |
description | This study aimed to evaluate the effect of autoclave sterilization on the integrity and instruments’ fracture number after multiple uses and cyclic fatigue of the original WaveOne Gold (Dentsply Sirona Endodontics) compared to four replica-like instruments (TF4-Gold, Roll-Wave-Gold, W-File, and Micro-Gold). The instruments were analyzed by scanning electron microscope (SEM) before being used in root canal instrumentation (baseline). One hundred and fifty human molars, freshly extracted for orthodontic reasons or periodontal disease and with severe curvature (between 30° and 60°), were used. Fifty teeth were instrumented with 10 instruments from each group and were evaluated for integrity. After sterilization in an autoclave, the instruments were analyzed by SEM. This procedure was repeated twice more, totaling three rounds of instrumentation, sterilization, and SEM analysis. Ten unused instruments from each group were evaluated for resistance to cyclic fatigue in a static test using a motor and a device simulating a canal with a 60° curvature angle. The instruments were driven by the motor until separation, visually verified, and the time measured in seconds. Data were analyzed by Chi-square, one-way ANOVA, and Tukey analysis, considering a significance level of 5%. It was found that there was no statistically significant difference between the groups tested in the effect of sterilization on the number of uses. The SEM analysis showed distortions in the instruments after the 3rd use. There was a statistically significant difference in the cyclic fatigue test between the results of WaveOne Gold, TF4 Gold, and Roll Wave Gold compared to W File and Micro Gold (P <0.0001) and a statistically significant difference between the W File and Micro Gold groups (P <0.0001). In conclusion, this study affirmed that WaveOne Gold, TF4-Gold, and Roll-Wave-Gold instruments exhibit comparable cyclic fatigue resistance. Besides, all examined instruments can be reliably employed for up to two cases. |
format | Article |
id | doaj-art-555e201b44cf47e8985ad571a91a99c0 |
institution | Kabale University |
issn | 1687-8736 |
language | English |
publishDate | 2024-01-01 |
publisher | Wiley |
record_format | Article |
series | International Journal of Dentistry |
spelling | doaj-art-555e201b44cf47e8985ad571a91a99c02025-02-03T07:23:38ZengWileyInternational Journal of Dentistry1687-87362024-01-01202410.1155/2024/6628146Effect of Autoclave Sterilization on the Number of Uses and Resistance to Cyclic Fatigue of WaveOne Gold and Four Replica-Like Endodontic InstrumentsGustavo Ragozzini0Amjad Abu Hasna1Fernando Antonio Siano dos Reis2Felipe Bernardo de Moura3Tiago Moreira Bastos Campos4Carlos Eduardo Silveira Bueno5Cláudio Antonio Talge Carvalho6Alexandre Sigrist de Martin7Faculdade São Leopoldo MandicDepartment of Restorative DentistryFaculdade São Leopoldo MandicDepartment of Restorative DentistryPhysics DepartmentFaculdade São Leopoldo MandicDepartment of Restorative DentistryFaculdade São Leopoldo MandicThis study aimed to evaluate the effect of autoclave sterilization on the integrity and instruments’ fracture number after multiple uses and cyclic fatigue of the original WaveOne Gold (Dentsply Sirona Endodontics) compared to four replica-like instruments (TF4-Gold, Roll-Wave-Gold, W-File, and Micro-Gold). The instruments were analyzed by scanning electron microscope (SEM) before being used in root canal instrumentation (baseline). One hundred and fifty human molars, freshly extracted for orthodontic reasons or periodontal disease and with severe curvature (between 30° and 60°), were used. Fifty teeth were instrumented with 10 instruments from each group and were evaluated for integrity. After sterilization in an autoclave, the instruments were analyzed by SEM. This procedure was repeated twice more, totaling three rounds of instrumentation, sterilization, and SEM analysis. Ten unused instruments from each group were evaluated for resistance to cyclic fatigue in a static test using a motor and a device simulating a canal with a 60° curvature angle. The instruments were driven by the motor until separation, visually verified, and the time measured in seconds. Data were analyzed by Chi-square, one-way ANOVA, and Tukey analysis, considering a significance level of 5%. It was found that there was no statistically significant difference between the groups tested in the effect of sterilization on the number of uses. The SEM analysis showed distortions in the instruments after the 3rd use. There was a statistically significant difference in the cyclic fatigue test between the results of WaveOne Gold, TF4 Gold, and Roll Wave Gold compared to W File and Micro Gold (P <0.0001) and a statistically significant difference between the W File and Micro Gold groups (P <0.0001). In conclusion, this study affirmed that WaveOne Gold, TF4-Gold, and Roll-Wave-Gold instruments exhibit comparable cyclic fatigue resistance. Besides, all examined instruments can be reliably employed for up to two cases.http://dx.doi.org/10.1155/2024/6628146 |
spellingShingle | Gustavo Ragozzini Amjad Abu Hasna Fernando Antonio Siano dos Reis Felipe Bernardo de Moura Tiago Moreira Bastos Campos Carlos Eduardo Silveira Bueno Cláudio Antonio Talge Carvalho Alexandre Sigrist de Martin Effect of Autoclave Sterilization on the Number of Uses and Resistance to Cyclic Fatigue of WaveOne Gold and Four Replica-Like Endodontic Instruments International Journal of Dentistry |
title | Effect of Autoclave Sterilization on the Number of Uses and Resistance to Cyclic Fatigue of WaveOne Gold and Four Replica-Like Endodontic Instruments |
title_full | Effect of Autoclave Sterilization on the Number of Uses and Resistance to Cyclic Fatigue of WaveOne Gold and Four Replica-Like Endodontic Instruments |
title_fullStr | Effect of Autoclave Sterilization on the Number of Uses and Resistance to Cyclic Fatigue of WaveOne Gold and Four Replica-Like Endodontic Instruments |
title_full_unstemmed | Effect of Autoclave Sterilization on the Number of Uses and Resistance to Cyclic Fatigue of WaveOne Gold and Four Replica-Like Endodontic Instruments |
title_short | Effect of Autoclave Sterilization on the Number of Uses and Resistance to Cyclic Fatigue of WaveOne Gold and Four Replica-Like Endodontic Instruments |
title_sort | effect of autoclave sterilization on the number of uses and resistance to cyclic fatigue of waveone gold and four replica like endodontic instruments |
url | http://dx.doi.org/10.1155/2024/6628146 |
work_keys_str_mv | AT gustavoragozzini effectofautoclavesterilizationonthenumberofusesandresistancetocyclicfatigueofwaveonegoldandfourreplicalikeendodonticinstruments AT amjadabuhasna effectofautoclavesterilizationonthenumberofusesandresistancetocyclicfatigueofwaveonegoldandfourreplicalikeendodonticinstruments AT fernandoantoniosianodosreis effectofautoclavesterilizationonthenumberofusesandresistancetocyclicfatigueofwaveonegoldandfourreplicalikeendodonticinstruments AT felipebernardodemoura effectofautoclavesterilizationonthenumberofusesandresistancetocyclicfatigueofwaveonegoldandfourreplicalikeendodonticinstruments AT tiagomoreirabastoscampos effectofautoclavesterilizationonthenumberofusesandresistancetocyclicfatigueofwaveonegoldandfourreplicalikeendodonticinstruments AT carloseduardosilveirabueno effectofautoclavesterilizationonthenumberofusesandresistancetocyclicfatigueofwaveonegoldandfourreplicalikeendodonticinstruments AT claudioantoniotalgecarvalho effectofautoclavesterilizationonthenumberofusesandresistancetocyclicfatigueofwaveonegoldandfourreplicalikeendodonticinstruments AT alexandresigristdemartin effectofautoclavesterilizationonthenumberofusesandresistancetocyclicfatigueofwaveonegoldandfourreplicalikeendodonticinstruments |