WWER-1000 accelerated unit unloading activation transient features
For WWER-1000 operation at power level more than 75 % of nominal one (Nnом) in case of failure of safety important equipment, the direct activation of accelerated unit unloading (AUU) signal is initiated. This causes the designated control rod regulating group to be dropped into the core to rapidly...