Positioning Error Analysis of Ultrasonic Shear Wave Detection for Railway Vehicle Shaft

Defect positioning error of railway vehicle shaft ultrasonic wave detection was analyzed. With test comparison of the two kinds of 13mm × 13mm and 22mm × 25mm size chip shaft shear wave oblique probe, K value measured deviation was found being the chief cause of ultrasonic wave detection axle positi...