Intravenous Misplacement of the Nephrostomy Catheter Into the Renal Vein Following Percutaneous Nephrolithotomy (PCNL): A Case Report and Literature Review

Conclusion: Intravenous nephrostomy tube misplacement is a rare PCNL complication. Good Imaging can rule out through and through renal vein perforation and thus patients can be safely managed using conservative approach.