A method using 3-points quadratic interpolation to process correlation spectrum peak data was proposed to improve precision of DSSS signal PN code phase measurement.The method used data points around correlation spec-trum peak to determine a quadratic interpolation function,then located the maximum...

Full description

Saved in:
Bibliographic Details
Main Authors: GONG Guo-hui, LI Si-kun
Format: Article
Language:zho
Published: Editorial Department of Journal on Communications 2007-01-01
Series:Tongxin xuebao
Subjects:
Online Access:http://www.joconline.com.cn/zh/article/74658959/
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1841537438406672384
author GONG Guo-hui
LI Si-kun
author_facet GONG Guo-hui
LI Si-kun
author_sort GONG Guo-hui
collection DOAJ
description A method using 3-points quadratic interpolation to process correlation spectrum peak data was proposed to improve precision of DSSS signal PN code phase measurement.The method used data points around correlation spec-trum peak to determine a quadratic interpolation function,then located the maximum point of the function so as to deter-mine the precise position of correlation spectrum peak,thus effectively increased the precision of measurement.Experi-ments show that the method reaches the goal of greatly increasing the precision of DSSS signal PN code phase measure-ment.
format Article
id doaj-art-347d357d2c934ddca5a82a119b01e22f
institution Kabale University
issn 1000-436X
language zho
publishDate 2007-01-01
publisher Editorial Department of Journal on Communications
record_format Article
series Tongxin xuebao
spelling doaj-art-347d357d2c934ddca5a82a119b01e22f2025-01-14T08:36:38ZzhoEditorial Department of Journal on CommunicationsTongxin xuebao1000-436X2007-01-0113013374658959Improving DSSS signal PN code phase measurement precision by 3-points quadratic interpolationGONG Guo-huiLI Si-kunA method using 3-points quadratic interpolation to process correlation spectrum peak data was proposed to improve precision of DSSS signal PN code phase measurement.The method used data points around correlation spec-trum peak to determine a quadratic interpolation function,then located the maximum point of the function so as to deter-mine the precise position of correlation spectrum peak,thus effectively increased the precision of measurement.Experi-ments show that the method reaches the goal of greatly increasing the precision of DSSS signal PN code phase measure-ment.http://www.joconline.com.cn/zh/article/74658959/DSSS signalPN code phase measurementFFT3-points quadratic interpolation
spellingShingle GONG Guo-hui
LI Si-kun
Improving DSSS signal PN code phase measurement precision by 3-points quadratic interpolation
Tongxin xuebao
DSSS signal
PN code phase measurement
FFT
3-points quadratic interpolation
title Improving DSSS signal PN code phase measurement precision by 3-points quadratic interpolation
title_full Improving DSSS signal PN code phase measurement precision by 3-points quadratic interpolation
title_fullStr Improving DSSS signal PN code phase measurement precision by 3-points quadratic interpolation
title_full_unstemmed Improving DSSS signal PN code phase measurement precision by 3-points quadratic interpolation
title_short Improving DSSS signal PN code phase measurement precision by 3-points quadratic interpolation
title_sort improving dsss signal pn code phase measurement precision by 3 points quadratic interpolation
topic DSSS signal
PN code phase measurement
FFT
3-points quadratic interpolation
url http://www.joconline.com.cn/zh/article/74658959/
work_keys_str_mv AT gongguohui improvingdssssignalpncodephasemeasurementprecisionby3pointsquadraticinterpolation
AT lisikun improvingdssssignalpncodephasemeasurementprecisionby3pointsquadraticinterpolation