Scanning Electrochemical Microscopy as a Tool for the Characterization of Dental Erosion

When the tooth is exposed to acidic environments, an irreversible loss of dental hard tissue occurs in a process called dental erosion. In this work, the scanning electrochemical microscopy (SECM) was used to probe the consumption of protons at the vicinity of a tooth surface with a platinum microel...

Full description

Saved in:
Bibliographic Details
Main Authors: Pollyana S. Castro, Alex S. Lima, Tiago L. Ferreira, Mauro Bertotti
Format: Article
Language:English
Published: Wiley 2011-01-01
Series:International Journal of Electrochemistry
Online Access:http://dx.doi.org/10.4061/2011/952470
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:When the tooth is exposed to acidic environments, an irreversible loss of dental hard tissue occurs in a process called dental erosion. In this work, the scanning electrochemical microscopy (SECM) was used to probe the consumption of protons at the vicinity of a tooth surface with a platinum microelectrode fixed at −0.5 (V) versus Ag/AgCl/KCl(sat). SECM approach curves were recorded to assess the extent of diffusion in the solution close to the tooth substrate. SECM images clearly demonstrated that the acid erosion process is very fast at solution pH values in the range between 3 and 4.