A novel transit-time flow metric, diastolic resistance index, detects subcritical anastomotic stenosis in coronary artery bypass graftingCentral MessagePerspective
Objective: Transit time flow measurement (TTFM) can detect critical anastomotic stenosis during coronary artery bypass grafting. However, the identification of subcritical stenosis remains challenging. We hypothesized that diastolic resistance index (DRI), a novel TTFM metric, is more effective in e...