Joint scheduling method of peak shaving and frequency regulation using hybrid energy storage considering degeneration characteristic

Abstract In this paper, a joint scheduling method of peak shaving and frequency regulation using hybrid energy storage system considering degeneration characteristic is proposed. Firstly, incorporating degradation costs of the hybrid energy storage system with respect to the depth of discharge and c...

Full description

Saved in:
Bibliographic Details
Main Authors: Yubo Wang, Xingang Zhao, Yujing Huang
Format: Article
Language:English
Published: Wiley 2024-12-01
Series:IET Renewable Power Generation
Subjects:
Online Access:https://doi.org/10.1049/rpg2.12968
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832579838991400960
author Yubo Wang
Xingang Zhao
Yujing Huang
author_facet Yubo Wang
Xingang Zhao
Yujing Huang
author_sort Yubo Wang
collection DOAJ
description Abstract In this paper, a joint scheduling method of peak shaving and frequency regulation using hybrid energy storage system considering degeneration characteristic is proposed. Firstly, incorporating degradation costs of the hybrid energy storage system with respect to the depth of discharge and cycle lifetime, long‐term costs of battery energy storage and flywheel energy storage are modelled and transformed to short‐term costs related to real‐time operation. Then, a joint scheduling model is proposed for hybrid energy storage system to perform peak shaving and frequency regulation services to coordinate and optimize the output strategies of battery energy storage and flywheel energy storage, and minimize the total operation cost of microgrid. In addition, three optimal dispatching strategies for hybrid energy storage system to participate in the auxiliary service of power grid are proposed based on the established auxiliary service model. Simulation studies demonstrate that the proposed joint scheduling method can optimize the power of different energy storage, alleviate the degradation process of battery energy storage. Compared with the scenario without scheduling hybrid energy storage system, scheduling hybrid energy storage system can reduce the total operation cost, and the electricity cost of microgrid is reduced by 13.13%.
format Article
id doaj-art-120ef4fe6ff5428aa946b0351bdddfa4
institution Kabale University
issn 1752-1416
1752-1424
language English
publishDate 2024-12-01
publisher Wiley
record_format Article
series IET Renewable Power Generation
spelling doaj-art-120ef4fe6ff5428aa946b0351bdddfa42025-01-30T12:15:53ZengWileyIET Renewable Power Generation1752-14161752-14242024-12-0118163765377510.1049/rpg2.12968Joint scheduling method of peak shaving and frequency regulation using hybrid energy storage considering degeneration characteristicYubo Wang0Xingang Zhao1Yujing Huang2North China Electric Power University Beijing ChinaNorth China Electric Power University Beijing ChinaNorth China Electric Power University Beijing ChinaAbstract In this paper, a joint scheduling method of peak shaving and frequency regulation using hybrid energy storage system considering degeneration characteristic is proposed. Firstly, incorporating degradation costs of the hybrid energy storage system with respect to the depth of discharge and cycle lifetime, long‐term costs of battery energy storage and flywheel energy storage are modelled and transformed to short‐term costs related to real‐time operation. Then, a joint scheduling model is proposed for hybrid energy storage system to perform peak shaving and frequency regulation services to coordinate and optimize the output strategies of battery energy storage and flywheel energy storage, and minimize the total operation cost of microgrid. In addition, three optimal dispatching strategies for hybrid energy storage system to participate in the auxiliary service of power grid are proposed based on the established auxiliary service model. Simulation studies demonstrate that the proposed joint scheduling method can optimize the power of different energy storage, alleviate the degradation process of battery energy storage. Compared with the scenario without scheduling hybrid energy storage system, scheduling hybrid energy storage system can reduce the total operation cost, and the electricity cost of microgrid is reduced by 13.13%.https://doi.org/10.1049/rpg2.12968battery management systemspower system management
spellingShingle Yubo Wang
Xingang Zhao
Yujing Huang
Joint scheduling method of peak shaving and frequency regulation using hybrid energy storage considering degeneration characteristic
IET Renewable Power Generation
battery management systems
power system management
title Joint scheduling method of peak shaving and frequency regulation using hybrid energy storage considering degeneration characteristic
title_full Joint scheduling method of peak shaving and frequency regulation using hybrid energy storage considering degeneration characteristic
title_fullStr Joint scheduling method of peak shaving and frequency regulation using hybrid energy storage considering degeneration characteristic
title_full_unstemmed Joint scheduling method of peak shaving and frequency regulation using hybrid energy storage considering degeneration characteristic
title_short Joint scheduling method of peak shaving and frequency regulation using hybrid energy storage considering degeneration characteristic
title_sort joint scheduling method of peak shaving and frequency regulation using hybrid energy storage considering degeneration characteristic
topic battery management systems
power system management
url https://doi.org/10.1049/rpg2.12968
work_keys_str_mv AT yubowang jointschedulingmethodofpeakshavingandfrequencyregulationusinghybridenergystorageconsideringdegenerationcharacteristic
AT xingangzhao jointschedulingmethodofpeakshavingandfrequencyregulationusinghybridenergystorageconsideringdegenerationcharacteristic
AT yujinghuang jointschedulingmethodofpeakshavingandfrequencyregulationusinghybridenergystorageconsideringdegenerationcharacteristic