Comparing the accuracy of computer-aided detection (CAD) software and radiologists from multiple countries for tuberculosis detection in chest X-Rays

Abstract Nearly a third of TB cases go undetected annually. WHO recommends computer-aided detection (CAD) to enhance TB screening, with studies showing comparable performance to local radiologists. Using 774 chest X-rays from the South African National TB Prevalence Survey, we compared 12 CAD softwa...

Full description

Saved in:
Bibliographic Details
Main Authors: Zhi Zhen Qin, Martie Van der Walt, Sizulu Moyo, Farzana Ismail, Phaleng Maribe, Claudia M. Denkinger, Sarah Zaidi, Rachael Barrett, Lindiwe Mvusi, Yolisa Tsibolane, Nkateko Mkhondo, Khangelani Zuma, Samuel Manda, Lisa Koeppel, Thuli Mthiyane, Jacob Creswell
Format: Article
Language:English
Published: Nature Portfolio 2025-07-01
Series:Scientific Reports
Online Access:https://doi.org/10.1038/s41598-025-06164-w
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Abstract Nearly a third of TB cases go undetected annually. WHO recommends computer-aided detection (CAD) to enhance TB screening, with studies showing comparable performance to local radiologists. Using 774 chest X-rays from the South African National TB Prevalence Survey, we compared 12 CAD software with 11 radiologists from Nigeria, India, the UK, and the US, against a composite microbiological reference standard. Sensitivity, specificity and Cohen’s kappa were calculated. Receiver-operating characteristic curves were developed for CAD and Euclidean distance assessed radiologists’ alignment with the best-performing software. Binomial regression tested the impact of radiologists’ characteristics on accuracy. Radiologist performance varied. On the restricted read, British radiologists had the highest sensitivity (78.7% [73.2–83.5%]) and Indian radiologists the lowest (67.1% [61.0–72.8%]). Specificity ranged from 75.8% (71.8–79.4%, Nigeria) to 84.3% (80.9–87.3%, the US). Radiologist performance was significantly impacted by HIV, prior TB, and age. The top CAD outperformed all except Indian radiologists when matching specificity. CAD with Conformité Européenne generally matched or surpassed radiologists. British radiologists’ sensitivity was closest to the top CAD, while American radiologists were closest in specificity and overall. Experience, TB reads, and country had no significant impact on accuracy. CAD performed well against radiologists globally, highlighting potential to enhance access to care.
ISSN:2045-2322