Algorithm for diagnosing insulation of power transformers by acoustic method in conditions of temperature changes

The article presents an algorithm for processing data by the acoustic method of insulation power transformers. The article presents data processing of diagnosing by the acoustic method of power transformers. A feature of the power supply system of railway transport is the location of traction s...

Full description

Saved in:
Bibliographic Details
Main Authors: A. A. Kuznetsov, V. V. Kharlamov, M. A. Volchanina
Format: Article
Language:English
Published: Omsk State Technical University, Federal State Autonoumos Educational Institution of Higher Education 2022-06-01
Series:Омский научный вестник
Subjects:
Online Access:https://www.omgtu.ru/general_information/media_omgtu/journal_of_omsk_research_journal/files/arhiv/2022/%E2%84%96%203%20(183)%20(%D0%9E%D0%9D%D0%92)/70-74%20%D0%9A%D1%83%D0%B7%D0%BD%D0%B5%D1%86%D0%BE%D0%B2%20%D0%90.%20%D0%90.,%20%D0%A5%D0%B0%D1%80%D0%BB%D0%B0%D0%BC%D0%BE%D0%B2%20%D0%92.%20%D0%92.,%20%D0%92%D0%BE%D0%BB%D1%87%D0%B0%D0%BD%D0%B8%D0%BD%D0%B0%20%D0%9C.%20%D0%90..pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832573394469519360
author A. A. Kuznetsov
V. V. Kharlamov
M. A. Volchanina
author_facet A. A. Kuznetsov
V. V. Kharlamov
M. A. Volchanina
author_sort A. A. Kuznetsov
collection DOAJ
description The article presents an algorithm for processing data by the acoustic method of insulation power transformers. The article presents data processing of diagnosing by the acoustic method of power transformers. A feature of the power supply system of railway transport is the location of traction substations along the railway track. For diagnosing power transformers advisable to use portable systems based on acoustic monitoring of partial discharges due to their high mobility and ease of installation. To improve the reliability of diagnosis under the conditions of seasonal temperature changes proposed use a defect simulator and a differential method for measuring the parameters of partial discharges. The scheme of the experiment and the diagnostic algorithm are proposed. Expressions are given that describe the properties of transformer oil with temperature changes, and changes in signal parameters during the propagation of acoustic waves. The data of diagnostics obtained on a power transformer at positive and negative temperatures under conditions of development of an insulation defect accompanied by partial discharges are presented.
format Article
id doaj-art-001842a031e24f148944f6dbe4039959
institution Kabale University
issn 1813-8225
2541-7541
language English
publishDate 2022-06-01
publisher Omsk State Technical University, Federal State Autonoumos Educational Institution of Higher Education
record_format Article
series Омский научный вестник
spelling doaj-art-001842a031e24f148944f6dbe40399592025-02-02T04:05:32ZengOmsk State Technical University, Federal State Autonoumos Educational Institution of Higher EducationОмский научный вестник1813-82252541-75412022-06-013 (183)707410.25206/1813-8225-2022-183-70-74Algorithm for diagnosing insulation of power transformers by acoustic method in conditions of temperature changesA. A. Kuznetsov0https://orcid.org/0000-0002-1815-4679V. V. Kharlamov1https://orcid.org/0000-0003-3621-3377M. A. Volchanina2https://orcid.org/0000-0003-3757-5580Omsk State Transport UniversityOmsk State Transport UniversityOmsk State Transport UniversityThe article presents an algorithm for processing data by the acoustic method of insulation power transformers. The article presents data processing of diagnosing by the acoustic method of power transformers. A feature of the power supply system of railway transport is the location of traction substations along the railway track. For diagnosing power transformers advisable to use portable systems based on acoustic monitoring of partial discharges due to their high mobility and ease of installation. To improve the reliability of diagnosis under the conditions of seasonal temperature changes proposed use a defect simulator and a differential method for measuring the parameters of partial discharges. The scheme of the experiment and the diagnostic algorithm are proposed. Expressions are given that describe the properties of transformer oil with temperature changes, and changes in signal parameters during the propagation of acoustic waves. The data of diagnostics obtained on a power transformer at positive and negative temperatures under conditions of development of an insulation defect accompanied by partial discharges are presented.https://www.omgtu.ru/general_information/media_omgtu/journal_of_omsk_research_journal/files/arhiv/2022/%E2%84%96%203%20(183)%20(%D0%9E%D0%9D%D0%92)/70-74%20%D0%9A%D1%83%D0%B7%D0%BD%D0%B5%D1%86%D0%BE%D0%B2%20%D0%90.%20%D0%90.,%20%D0%A5%D0%B0%D1%80%D0%BB%D0%B0%D0%BC%D0%BE%D0%B2%20%D0%92.%20%D0%92.,%20%D0%92%D0%BE%D0%BB%D1%87%D0%B0%D0%BD%D0%B8%D0%BD%D0%B0%20%D0%9C.%20%D0%90..pdfpower transformersacoustic methodpartial dischargesinsulation diagnosticsdefect simulatorsignal parameters
spellingShingle A. A. Kuznetsov
V. V. Kharlamov
M. A. Volchanina
Algorithm for diagnosing insulation of power transformers by acoustic method in conditions of temperature changes
Омский научный вестник
power transformers
acoustic method
partial discharges
insulation diagnostics
defect simulator
signal parameters
title Algorithm for diagnosing insulation of power transformers by acoustic method in conditions of temperature changes
title_full Algorithm for diagnosing insulation of power transformers by acoustic method in conditions of temperature changes
title_fullStr Algorithm for diagnosing insulation of power transformers by acoustic method in conditions of temperature changes
title_full_unstemmed Algorithm for diagnosing insulation of power transformers by acoustic method in conditions of temperature changes
title_short Algorithm for diagnosing insulation of power transformers by acoustic method in conditions of temperature changes
title_sort algorithm for diagnosing insulation of power transformers by acoustic method in conditions of temperature changes
topic power transformers
acoustic method
partial discharges
insulation diagnostics
defect simulator
signal parameters
url https://www.omgtu.ru/general_information/media_omgtu/journal_of_omsk_research_journal/files/arhiv/2022/%E2%84%96%203%20(183)%20(%D0%9E%D0%9D%D0%92)/70-74%20%D0%9A%D1%83%D0%B7%D0%BD%D0%B5%D1%86%D0%BE%D0%B2%20%D0%90.%20%D0%90.,%20%D0%A5%D0%B0%D1%80%D0%BB%D0%B0%D0%BC%D0%BE%D0%B2%20%D0%92.%20%D0%92.,%20%D0%92%D0%BE%D0%BB%D1%87%D0%B0%D0%BD%D0%B8%D0%BD%D0%B0%20%D0%9C.%20%D0%90..pdf
work_keys_str_mv AT aakuznetsov algorithmfordiagnosinginsulationofpowertransformersbyacousticmethodinconditionsoftemperaturechanges
AT vvkharlamov algorithmfordiagnosinginsulationofpowertransformersbyacousticmethodinconditionsoftemperaturechanges
AT mavolchanina algorithmfordiagnosinginsulationofpowertransformersbyacousticmethodinconditionsoftemperaturechanges