Showing 1,721 - 1,740 results of 6,806 for search 'surface detection', query time: 0.12s Refine Results
  1. 1721

    Exploring the Ocular Transmission Potential of Severe Acute Respiratory Syndrome Coronavirus 2 and the Assessment of Conjunctival Swab Test Results: A Concise Review by Arash Mirzaei, Ali Djalilian, Seyed Mahbod Baharnoori, Bahram Bohrani Sefidan, Mansoor Shahriari, Kasra Cheraqpour, Mahmood Ghassemi, Allison Kufta, Mohammad Soleimani

    Published 2024-04-01
    “…Purpose: To evaluate the possibility of coronavirus disease 2019 (COVID-19) transmission through the eyes, particularly through the ocular surface and conjunctival route, as well as the positivity of conjunctival swab test. …”
    Get full text
    Article
  2. 1722

    Flexible eddy current array measurement system for crack detection in weld zones of steel structures by Le Quang Trung, Nguyen Duc Khuong, Tran Thi Hoai Dung, Naoya Kasai, Tran Mach Tuan Kiet, Kouichi Sekino, Honoka Fukuda

    Published 2025-07-01
    “…Eddy current (EC) testing is widely used due to its non-contact nature and high sensitivity to surface and sub-surface cracks. This study reports a flexible eddy current array (FECA) sensor with six bendable channels designed to detect surface and sub-surface cracks in the weld zones of steel structures. …”
    Get full text
    Article
  3. 1723

    Detection of Elusive Rogue Wave with Cross-Track Interferometric Synthetic Aperture Radar Imaging Approach by Tung-Cheng Wang, Jean-Fu Kiang

    Published 2025-04-01
    “…The retrieval of sea surface height via remote sensing techniques provides a viable solution for detecting rogue waves. …”
    Get full text
    Article
  4. 1724
  5. 1725

    Electrochemical detection of amine neurotransmitters is drastically different in buffer solutions, in vivo, and cell culture systems by Samuel Rantataro, Laura Ferrer Pascual, Tomi Laurila

    Published 2024-12-01
    “…However, electrochemical detection of amine neurotransmitters is highly dependent on electrode surface condition and thus, results obtained in clean buffer solutions are not directly applicable to the real measurement environment in vivo or in vitro. …”
    Get full text
    Article
  6. 1726

    Dynamic rasterstereography improves the detection of movement delays and dynamic asymmetries in the scapulothoracic kinematic of healthy subjects by Richard Julius Freytag, Jonas Wilhelm Moss, Filippo Maria Piana Jacquot, Jakob Zapatka, Rebecca Herrmann, Mahmoud Ragab, Sebastian Scheidt, Davide Cucchi

    Published 2024-10-01
    “…However, no differences were found in static asymmetry and rapid compensatory movement detection. Conclusions DRS can create a real‐time model of the trunk surface and allows observers to evaluate the scapular movements with good‐to‐excellent intrarater and interrater reproducibility; compared to clinical observation, some specific scapular motion alterations can be observed more frequently. …”
    Get full text
    Article
  7. 1727

    Microextraction of Polycyclic Musks from Surface Water with Deep-Eutectic-Solvent-Coated Membrane Followed by Gas-Chromatography–Mass Spectrometry Analysis by Fabiana Terlizzi, José O. Fernandes, Tamara Gonzalez, Mateus H. Petrarca, Leandro dos S. Silva, Rafaela S. Lamarca, Mario H. Gonzalez, Rui Lapa, Sara C. Cunha

    Published 2025-03-01
    “…The DES-coated membrane demonstrated a linear detection range from 2.5 to 100 μg/L, with limits of detection (LODs) ranging from 0.06 to 0.15 µg/L, while the LOQ values varied from 0.2 to 0.5 µg/L. …”
    Get full text
    Article
  8. 1728

    A novel electrochemical immunosensor based on biomaterials for detecting carcinoembryonic antigen biomarker in serum samples by Sajedeh Sobhanparast, Payam Shahbazi-Derakhshi, Jafar Soleymani, Amir Amiri-Sadeghan, Alireza Herischi, Nader Chaparzadeh, Younes Aftabi

    Published 2025-07-01
    “…This modification enhanced the functional surface area and electrode conductivity, thereby improving the electrochemical response and sensitivity for CEA detection. …”
    Get full text
    Article
  9. 1729

    A fuzzy system for detection of road slipperiness in Arctic snowy conditions using LiDAR by Aqsa Rahim, Sushmit Dhar, Fuqing Yuan, Javad Barabady

    Published 2025-07-01
    “…However, their operation in Arctic environments remains challenging due to snow, ice, and slush, which negatively impact traction and road surface perception. To address these challenges, this study integrates LiDAR-based reflected intensity measurements with environmental parameters such as humidity, temperature, and the coefficient of friction to detect road surface slipperiness and roughness. …”
    Get full text
    Article
  10. 1730

    A Hollow-Core Photonic Crystal Fiber-Based SPR Sensor With Large Detection Range by Nannan Luan, Jianquan Yao

    Published 2017-01-01
    “…We propose a large detection range surface plasmon resonance (SPR) sensor based on hollow-core photonic crystal fiber in this paper. …”
    Get full text
    Article
  11. 1731

    Risk factors for Carbapenem-resistant Acinetobacter baumannii contamination on hospital surfaces: a multi-year environmental monitoring study in Shanghai, China by Xing Zhang, Liang Tian, Jiaying Wu, Taiyao Chen, Tingting Shi, Yilin Ge, Renyi Zhu, Jian Chen

    Published 2025-06-01
    “…Therefore, it is necessary to investigate the distribution of CRAB in the environment and identify the risk factors associated with its positive detection rate.MethodsFrom 2018 to 2023, long-term environmental monitoring of surfaces around CRAB patients was conducted across 16 hospitals in Shanghai. …”
    Get full text
    Article
  12. 1732
  13. 1733

    Defect Detection Method of Carbon Fiber Unidirectional Band Prepreg Based on Enhanced YOLOv8s by Weipeng Su, Mei Sang, Yutong Liu, Xueming Wang

    Published 2025-04-01
    “…To address the challenges in existing carbon fiber prepreg surface defect detection processes, specifically difficulties in small target detection and inaccuracies in elongated defects with large aspect ratios, this study proposes an enhanced YOLOv8s-based models for defect detection on the surface of carbon fiber unidirectional band prepreg. …”
    Get full text
    Article
  14. 1734

    Detection of Steel Reinforcement in Concrete Using Active Microwave Thermography and Neural Network-Based Analysis by Barbara Szymanik, Maja Kocoń, Sam Ang Keo, Franck Brachelet, Didier Defer

    Published 2025-07-01
    “…The model was trained exclusively on simulation data and subsequently validated using experimental measurements obtained from large-format concrete slabs incorporating a structured layout of embedded steel reinforcement bars. Surface temperature distributions obtained through infrared imaging were compared with model predictions to evaluate detection accuracy. …”
    Get full text
    Article
  15. 1735

    Enzyme-Based Solid-Phase Electrochemiluminescence Sensors with Stable, Anchored Emitters for Sensitive Glucose Detection by Chunyin Wei, Yanyan Zheng, Fei Yan, Lifang Xu

    Published 2025-05-01
    “…By replacing the enzyme type on the electrode surface, this sensing strategy holds the potential to provide a universal platform for the detection of different metabolites.…”
    Get full text
    Article
  16. 1736

    A Highly Sensitive Silicon-Core Quantum Dot Fluorescent Probe for Vomitoxin Detection in Cereals by Caiwen Dong, Yaqin Li, Xincheng Sun, Xuehao Yang, Tao Wei

    Published 2025-04-01
    “…In this study, an on-site immune detection method based on an immune SiO<sub>2</sub>@QD fluorescent probe was developed, which realized the rapid and quantitative detection of emetic toxins in grains. …”
    Get full text
    Article
  17. 1737

    Immobilization of DNA Aptamers on Polyester Cloth for Antigen Detection by Dot Blot Immunoenzymatic Assay (Aptablot) by Sally Smiley, Maria DeRosa, Burton Blais

    Published 2013-01-01
    “…Bound thrombin was detected immunoenzymatically using a peroxidase-linked antithrombin antibody and a chromogenic substrate. …”
    Get full text
    Article
  18. 1738

    Study on the detection and suppression methods of carbon laying defects in auto fiber placement (AFP) process by Yixuan Xie, Zhiqiang Liu, Yinqi Li, Yueyue Zong

    Published 2025-02-01
    “…The minimum edge detection rate on both sides of a single layer reaches 94.3%, and the interlayer gap measurement is below 10%. …”
    Get full text
    Article
  19. 1739

    A Triple-Channel Network for Maritime Radar Targets Detection Based on Multi-Modal Features by Kaiqi Wang, Zeyu Wang

    Published 2024-12-01
    “…Sea surface target detectors are often interfered by various complex sea surface factors such as sea clutter. …”
    Get full text
    Article
  20. 1740

    An electrochemical aptasensor for detection of Helicobacter pylori based on AuNPs and AgNPs-GO nanoparticles by Xiaojuan You, Xiaojuan You, Xiaojuan You, Xiaojuan You, Mingyi Shao, Mingyi Shao, Huadong Wang, Rui Zhu, Xinwei Liu, Lei Dong, Yuesheng Gong, Yongwei Li, Yongwei Li

    Published 2025-07-01
    “…Helicobacter pylori is one of the main causes of gastritis and gastric ulcer. Early detection of H. pylori is of great significance for the prevention of gastric cancer. …”
    Get full text
    Article