1
A Partial Discharge Detection Approach in Distribution Cabinets Using a Mach–Zehnder Interferometer
Published 2025-04-01“…This paper proposes a partial discharge (PD) detection approach based on a fiber-optic Mach–Zehnder interferometer (MZI). …”
Get full text
Article -
2
Improving Limit-of-Detection in High-Sensitivity Plasmo-Photonic Mach-Zehnder Interferometer Refractive Index Sensors
Published 2025-01-01“…This work presents a dual plasmo-photonic branch Mach-Zehnder interferometer refractive index sensor integrated on a Si<sub>3</sub>N<sub>4</sub> platform, with both the sensor and reference arms hosting identical aluminum plasmonic metal stripes. …”
Get full text
Article -
3
Enhanced Sensitivity Mach–Zehnder Interferometer-Based Tapered-in-Tapered Fiber-Optic Biosensor for the Immunoassay of C-Reactive Protein
Published 2025-02-01“…A Mach–Zehnder interferometer-based tapered-in-tapered fiber-optic biosensor was introduced in this paper. …”
Get full text
Article -
4
High-Precision Interferometric Measurements of Gas Refractive Index Using Homodyne Detection
Published 2025-06-01Subjects: “…homodyne detection…”
Get full text
Article -
5
Quantum computation with photochromic films in a Mach–Zehnder interferometer
Published 2024-11-01“…This results in a change in the probability of detecting a photon by the two detectors after the second mirror of the Mach–Zehnder interferometer. …”
Get full text
Article -
6
SLAMS-propelled Electron Acceleration at High-Mach-number Astrophysical Shocks
Published 2025-01-01“…Short large-amplitude magnetic structures (SLAMS) are frequently detected during spacecraft crossings over Earth's bow shock. …”
Get full text
Article -
7
Direct-Detection OFDM Transmission Using Four-State Chirp Control With a Dual-Electrode MZM for Dispersion Compensation
Published 2018-01-01Subjects: “…Direct detection…”
Get full text
Article -
8
An Efficient pH Detector for Water Contamination Based on Mach–Zehnder Interferometer Application
Published 2024-12-01“…This paper presents a pH sensor with a Mach–Zehnder Interferometer (MZI) that operates in solutions of 4.0, 7.0, and 10.0. …”
Get full text
Article -
9
Optical Fiber Methane Sensor Based on Mach–Zehnder Interferometer Induced by Multimode Interference
Published 2025-03-01Get full text
Article -
10
Ultra-Compact Mach–Zehnder Refractometer Based on Rice-Shaped Air Cavity Beam Expansion
Published 2025-06-01“…This paper reports and demonstrates, for the first time, a Mach–Zehnder interferometer (MZI) sensor for refractive index (RI) detection based on a rice-shaped air cavity (RAC). …”
Get full text
Article -
11
High-Sensitivity Magnetic Field Sensor Based on an Optoelectronic Oscillator with a Mach–Zehnder Interferometer
Published 2025-03-01“…A high-sensitivity magnetic field sensor based on an optoelectronic oscillator (OEO) with a Mach–Zehnder interferometer (MZI) is proposed and experimentally demonstrated. …”
Get full text
Article -
12
Displaced thinned single-mode fiber Mach-Zehnder interferometer tested for temperature and curvature applications
Published 2024-12-01“…This article explains the features and qualities of employing a thinned manufacturing fiber to assemble a Mach-Zehnder interferometer (MZI) for detecting two physical variables: temperature and curvature. …”
Get full text
Article -
13
Lateral Stress Sensor Based on an In-Fiber Mach–Zehnder Interferometer and Fourier Analysis
Published 2016-01-01“…A novel lateral stress sensor based on a compact in-fiber Mach–Zehnder interferometer (MZI) and Fourier analysis is proposed and demonstrated. …”
Get full text
Article -
14
-
15
Cost-Effective Mach-Zehnder Interferometer Liquid Refractive Index Sensor Based on Conventional Polymer Strip Waveguide
Published 2021-01-01“…We propose and demonstrate a cost-effective liquid refractive index (RI) sensor in polymer materials by employing a Mach-Zehnder interferometer (MZI) formed with the conventional strip waveguide. …”
Get full text
Article -
16
Dual Mach–Zehnder Interferometer Based on Side-Hole Fiber for High-Sensitivity Refractive Index Sensing
Published 2019-01-01“…A unique type of refractive index (RI) sensor is proposed using a dual Mach-Zehnder interferometer (MZI) structure based on side-hole fibers (SHFs). …”
Get full text
Article -
17
Using an Auxiliary Mach–Zehnder Interferometer to Compensate for the Influence of Laser-Frequency-Drift in Φ-OTDR
Published 2019-01-01“…In this paper, we propose a method to compensate for the influence of the frequency drift by using an auxiliary Mach–Zehnder interferometer (MZI). In this method, the signal of the auxiliary MZI is received to monitor the frequency drift continuously, and then, to correct the signal obtained from the sensing path. …”
Get full text
Article -
18
-
19
Flexible eddy current array measurement system for crack detection in weld zones of steel structures
Published 2025-07-01Get full text
Article -
20
Aflatoxin M1 Determination in Whole Milk with Immersible Silicon Photonic Immunosensor
Published 2025-03-01“…Here, a rapid and sensitive method for detecting AFM1 in milk based on an immersible silicon photonic chip is presented. …”
Get full text
Article