Search alternatives:
systemic » systematic (Expand Search)
Showing 301 - 320 results of 333 for search 'linear systemic array', query time: 0.18s Refine Results
  1. 301

    Determination of Cortisol Levels in a Small Volume of Saliva of COVID-19-Recovering Patients During Treatment with Psychotropic Drugs by Ewelina Dziurkowska, Grażyna Guz-Rzeniecka, Maciej Dziurkowski

    Published 2025-03-01
    “…Long-term exposure to high cortisol levels has a destructive effect on the CNS (Central Nervous System) and can lead to depression, among other things. …”
    Get full text
    Article
  2. 302
  3. 303
  4. 304

    Compact and Handheld SiPM-Based Gamma Camera for Radio-Guided Surgery and Medical Imaging by Fabio Acerbi, Aramis Raiola, Cyril Alispach, Hossein Arabi, Habib Zaidi, Alberto Gola, Domenico Della Volpe

    Published 2025-06-01
    “…This is based on a particular position-sensitive Silicon Photomultiplier (SiPM) technology—the FBK linearly graded SiPM (LG-SiPM). Within the camera, the photodetector is made up of a 3 × 3 array of 10 × 10 mm<sup>2</sup> SiPM chips having a total area of more than 30 × 30 mm<sup>2</sup>. …”
    Get full text
    Article
  5. 305

    Psychological Features of 7-8 Grade Students Interaction with Hypertext: A Theoretical and Experimental Study Using an Eye Tracker by N.A. Borisenko, A.A. Ganicheva, K.V. Mironova, S.V. Shishkova

    Published 2025-06-01
    “…Despite a significant array of hypertext studies, most of them are theoretical, and there is a shortage of works on educational hypertext. …”
    Get full text
    Article
  6. 306

    Development of a transportable High-Performance Liquid Chromatograph with Ultraviolet detection and a method for the rapid analysis of 13 carbonyl compounds hydrazones by Audrey Grandjean, Anaïs Becker, Mathilde Mascles, Franck Amiet, Jean-Philippe Amiet, Damien Bazin, Stéphane Le Calvé

    Published 2025-05-01
    “…Performances were close to that of the laboratory HPLCs, either in sensitivity, resolution, or repeatability with overall more accurate and robust results with the UV than with the LED detector. Despite the LED system not fully meeting the standard method requirements with linearities correlation coefficients lower than 0.999, both systems and methods were validated for the isocratic analysis of hydrazones for aldehydes and ketones quantification. …”
    Get full text
    Article
  7. 307

    Dose distribution in a radiosurgery treatment for an acoustic neuroma by Marco Antonio Costa Cardoso, Victor Gabriel Leandro Alves, Simone Coutinho Cardoso

    Published 2021-06-01
    “…The established approach of transforming 2D arrays of dose in a 3D one is satisfactory, validating it. …”
    Get full text
    Article
  8. 308

    Low-power scalable multilayer optoelectronic neural networks enabled with incoherent light by Alexander Song, Sai Nikhilesh Murty Kottapalli, Rahul Goyal, Bernhard Schölkopf, Peer Fischer

    Published 2024-12-01
    “…This study introduces a multilayer optoelectronic computing framework that alternates between optical and optoelectronic layers to implement matrix-vector multiplications and rectified linear functions, respectively. Our framework is designed for real-time, parallelized operations, leveraging 2D arrays of LEDs and photodetectors connected via independent analog electronics. …”
    Get full text
    Article
  9. 309

    Green RP-HPLC method for simultaneous quantification of epigallocatechin-3-gallate and rosmarinic acid in lipid-based nanocarriers and biological fluids: Quality by design-driven o... by Rahul Koli, V.S. Mannur

    Published 2024-12-01
    “…Initially, variations in critical analytical attributes were identified using the Ishikawa fishbone diagram and Risk Priority Number scores. A Taguchi Orthogonal Array design was employed to screen the critical method parameters influencing method development. …”
    Get full text
    Article
  10. 310

    Kinetic Pathway Control in the Synthesis of Well‐Defined Ruthenium Coordination Oligomers by Tilman Schneider, Florian Seebauer, Frank Würthner, Florian Beuerle

    Published 2025-05-01
    “…In this context, the accumulation of active Ru centers in macrocyclic arrays or coordination oligomers and polymers has proven to be very beneficial for an enhanced stability under operating conditions and to facilitate surface adhesion in heterogeneous systems. …”
    Get full text
    Article
  11. 311

    An agent-based model of signal transduction in bacterial chemotaxis. by Jameson Miller, Miles Parker, Robert B Bourret, Morgan C Giddings

    Published 2010-05-01
    “…We report the application of agent-based modeling to examine the signal transduction network and receptor arrays for chemotaxis in Escherichia coli, which are responsible for regulating swimming behavior in response to environmental stimuli. …”
    Get full text
    Article
  12. 312

    A Spherical Micro Satellite Design and Detection Method for Upper Atmospheric Density Estimation by Zeyang Zhao, Zhaokui Wang, Yulin Zhang

    Published 2019-01-01
    “…The influence of the components of the antenna, separation support, and solar cell arrays (SCAs) on the spherical structure for the area-to-mass ratio is reduced by reasonable design of the satellite flight attitude. …”
    Get full text
    Article
  13. 313

    Landau–Zener without a qubit: multiphoton sidebands interaction and signatures of dissipative quantum chaos by Léo Peyruchat, Fabrizio Minganti, Marco Scigliuzzo, Filippo Ferrari, Vincent Jouanny, Franco Nori, Vincenzo Savona, Pasquale Scarlino

    Published 2025-04-01
    “…We fabricate two superconducting resonators with flux-tunable Josephson junction arrays. The first device, exhibiting weak nonlinearity, behaves like a linear resonator under weak driving but shows LZSM interference akin to two-level systems. …”
    Get full text
    Article
  14. 314

    Development of a superheated water chromatography method for the sustainable determination of preservatives in foods and cosmetics by Roberta La Tella, Danilo Donnarumma, Francesca Rigano, Paola Donato, Patrik Appelblad, Paola Dugo, Luigi Mondello, Alice Mondello

    Published 2024-12-01
    “…Hardware modifications were also necessary to guarantee the efficient heating of the mobile phase prior of entering the column, as well as its rapid cooling before detection by photodiode array (PDA). Specifically, an LC system was interfaced to a GC oven, which hosted the LC column; to achieve a fast and efficient heating of the eluent coming from the autosampler prior to enter into the column, a pre-heating tube was interposed between the autosampler outlet and the column inlet. …”
    Get full text
    Article
  15. 315

    Full-Duplex Millimeter Wave MIMO Channel Estimation: A Neural Network Approach by Mehdi Sattari, Hao Guo, Deniz Gunduz, Ashkan Panahi, Tommy Svensson

    Published 2024-01-01
    “…We study full-duplex transmissions as an effective way to improve mmWave MIMO systems. Compared to half-duplex systems, full-duplex transmissions may offer higher data rates and lower latency. …”
    Get full text
    Article
  16. 316

    Eco-friendly QbD-optimized chromatographic method for simultaneous analysis of metronidazole and nicotinamide with applications in permeation, stability, and sustainability evaluat... by Kanaka Parvathi Kannaiah, Mohamed A. M. Ali, Hemanth Kumar Chanduluru, Anis Ahmad Chaudhary, Mahmoud El-Maghrabey, Reem H. Obaydo, Galal Magdy, Mohamed A. El Hamd

    Published 2025-07-01
    “…Chromatographic separations were conducted with an RP-HPLC-photodiode array (PDA) system equipped with an ODS column using gradient elution of ethanol and phosphate buffer (10 mM, pH 3.5) at a flow rate of 1.0 mL/min. pre-optimized conditions were determined using a two-level full factorial design (23 FFD). …”
    Get full text
    Article
  17. 317

    Reprocessing from Highly Ionized Gas in the Soft Spectral State of V4641 Sgr with NuSTAR by Riley M. T. Connors, Joey Neilsen, Aarran W. Shaw, James F. Steiner, Federico Vincentelli, Javier A. García, Phil Uttley, Ronald A. Remillard, Guglielmo Mastroserio

    Published 2025-01-01
    “…V4641 Sgr is a low-mass black hole X-ray binary system with somewhat puzzling spectral characteristics during its soft state. …”
    Get full text
    Article
  18. 318

    The Detection of Spatially Resolved Protostellar Outflows and Episodic Jets in the Outer Galaxy by Toki Ikeda, Takashi Shimonishi, Natsuko Izumi, Hiroyuki Kaneko, Satoko Takahashi, Kei E. I. Tanaka, Kenji Furuya, Chikako Yasui

    Published 2025-01-01
    “…We observed five star-forming regions in the outer Galaxy (Sh 2-283 and NOMF05-16/19/23/63; galactocentric distance = 15.7–17.4 kpc) with the Atacama Large Millimeter/submillimeter Array. Toward Sh 2-283, we have detected distinct outflow (∼5–50 km s ^−1 ) and jet components (∼50–100 km s ^−1 ) associated with the protostar in CO(3–2) emission. …”
    Get full text
    Article
  19. 319

    Computational fluid dynamics and machine learning integration for evaluating solar thermal collector efficiency -Based parameter analysis by Xiaoyu Hu, Lanting Guo, Jiyuan Wang, Yang Liu

    Published 2025-07-01
    “…Abstract The present paper provides a novel hybrid computational framework that integrates Computational Fluid Dynamics (CFD) with advanced machine learning techniques to optimize solar thermal collectors employing micro-heat pipe arrays (MHPA) for food dehydration applications. The methodology addresses the fundamental challenge of balancing computational efficiency with prediction accuracy in thermal system design. …”
    Get full text
    Article
  20. 320

    First performance evaluation of easyPET.3D, a high-resolution and cost-effective benchtop preclinical PET scanner by Fabiana M. Ribeiro, Pedro M. C. C. Encarnação, Ana L. M. Silva, Pedro M. M. Correia, Afonso X. Pinto, Regina G. Oliveira, José Sereno, Mariana Lapo Pais, Antero Abrunhosa, Ismael F. Castro, Ana C. Santos, João F. C. A. Veloso

    Published 2025-05-01
    “…Conclusion EasyPET.3D geometry favours the reduction of parallax error, despite its low sensitivity. The system linearity is suitable for the low range of activities (7–8 MBq) used for mice imaging. …”
    Get full text
    Article