    Developing a Multisensor-Based Machine Learning Technology (Aidar Decompensation Index) for Real-Time Automated Detection of Post–COVID-19 Condition: Protocol for an Observational... by Jenny Mathew, Jaclyn A Pagliaro, Sathyanarayanan Elumalai, Lauren K Wash, Ka Ly, Alison J Leibowitz, Varsha G Vimalananda

    Published 2025-03-01
    “…ConclusionsThe focus on identifying predictor variables using a combination of biosensor-derived physiological features should enable the capture of heterogeneous characteristics of complications related to post–COVID-19 condition across diverse populations. …”
    Get full text
    Article
  2. 242
  3. 243

    Construction and application of foundational models for intelligent processing of microseismic events in mines by Anye CAO, Maotao LI, Xu YANG, Yao YANG, Sen LI, Yaoqi LIU, Changbin WANG

    Published 2025-06-01
    “…To address these challenges, this study developed a Transformer-based foundational model for intelligent microseismic processing by integrating big data analytics and deep learning theories. A comprehensive dataset containing over 300 000 microseismic waveforms was established, incorporating three key innovations: multi-scale convolutional modules for multi-dimensional feature extraction, an adaptive feature fusion strategy for noise-resistant signal representation, and a feature-aggregated multi-head attention mechanism for temporal sequence modeling. …”
    Get full text
    Article
  4. 244

    Modeling of a Novel T-Core Sensor with an Air Gap for Applications in Eddy Current Nondestructive Evaluation by Siquan Zhang

    Published 2024-12-01
    “…Compared to the finite element method (FEM), analytical approaches offer advantages, such as faster computation and high accuracy, enabling a comprehensive analysis of how sensor and material parameters influence defect detection outcomes. …”
    Get full text
    Article
  5. 245

    Recent Advances in Calixarene-Based Fluorescent Sensors for Biological Applications by Paula M. Marcos, Mário N. Berberan-Santos

    Published 2024-11-01
    “…In addition to the fluorescence mechanisms used to signal the analyte binding, this article focuses mainly on the detection of biological relevant ions, on the selective sensing of biomolecules, such as amino acids, enzymes, drugs and other organic compounds, and on intracellular imaging. …”
    Get full text
    Article
  6. 246
  7. 247
  8. 248
  9. 249
  10. 250

    Recent advances in the design of SERS substrates and sensing systems for (bio)sensing applications: Systems from single cell to single molecule detection [version 3; peer review: 3... by Pooja Nag, Kapil Sadani, Sreelakshmi C S, Chiranjay Mukhopadhyay, Anirudh Bharadwaj, Ashwini G Shenoy, Sai Ratnakar Tadi

    Published 2025-06-01
    “…The advancements in these technologies have been reviewed and critiqued for analyte detection in resource-limited settings, highlighting the prospects of applications ranging from single-molecule to single-cell detection. …”
    Get full text
    Article
  11. 251

    Analysis of the ion mobility spectra of chloroacetophenone, tris(2-chloroethyl)amine, and methanethiol by D. A. Aleksandrova, T. B. Melamed, E. P. Baberkina, E. S. Osinova, L. A. Luzenina, A. A. Kaplin, R. V. Yakushin, A. E. Kovalenko, G. V. Tsaplin, Yu. B. Sinkevich, A. A. Fenin, J. R. Shaltaeva, V. V. Belyakov, A. O. Shablya, A. G. Sazonov

    Published 2024-11-01
    “…Ion mobility spectrometry was used in order to determine the ion mobilities and detect analytes. The enthalpies of reactions of ion formation were calculated using the ORCA 4.1.1 software by means of the B3LYP density functional method with the 6-31G(d,p) basis set.Results. …”
    Get full text
    Article
  12. 252

    Large deflection angle resonant 1D scanning micromirror fabricated with multi jet fusion 3D printed parts by Wookyung Kim, Jeong-Yeon Hwang, Chang-Hyeon Ji

    Published 2024-12-01
    “…The micromirror serves as a horizontal scanner in a two-dimensional scan module for light detection and ranging. It features a self-supported coil for electromagnetic actuation, and its design is validated through analytical and finite element analyses. …”
    Get full text
    Article
  13. 253

    Automated capillary electrophoresis analyses of dried blood samples after patient-centric volumetric absorptive microsampling by Richard Maršala, Miloš Dvořák, Pavel Kubáň

    Published 2025-02-01
    “…A single commercial capillary electrophoresis (CE) instrument (with no need for hardware or software modifications) was employed for the expeditious analyses of the dried material using several integral and novel features. These included the use of external pressure for sub-minute sample preparation from Mitra® VAMS polymeric tips, the use of the sampling tips as inherent micro-agitators for instant eluate homogenization, preparation/sampling at the CE outlet for more convenient capillary length adjustment, and short-end injection for sub-minute CE separation and quantification of lactate as a model analyte.The operational parameters for the sample preparation and analysis were comprehensively evaluated resulting in a baseline separation of lactate from all endogenous matrix compounds. …”
    Get full text
    Article
  14. 254

    Evaluation criteria of centralization options in the architecture of multicomputer systems with traps and baits by Antonina Kashtalian, Sergii Lysenko, Anatoliy Sachenko, Bohdan Savenko, Oleg Savenko, Andrii Nicheporuk

    Published 2025-02-01
    “…New mathematical models were developed for the criteria for operational efficiency, stability, integrity and security in relation to the system center, which, unlike the known mathematical models for evaluating system centers for selecting the next options for centralization, are presented in analytical expressions that take into account the features of the types of centralization in the system architecture, indicators of operational efficiency, stability, integrity and security in relation to the system center and allow forming on their basis an objective function for evaluating options for centralization in systems, the feature of which is the hiding of components with the system center from detection by attackers. …”
    Get full text
    Article
  15. 255
  16. 256

    Helicobacter pylori Detection Based on Synergistic Electromagnetic and Chemical Enhancement of Surface‐Enhanced Raman Scattering in 3D Hotspot‐Activated Gold Nanorods/Nano Mica Pla... by Ming‐Chang Lu, Yung‐Chi Yang, Chia‐Jung Lee, Chih‐Wei Chiu

    Published 2025-07-01
    “…The high anionic charge and specific surface area of NMPs stabilize AuNR growth and benefit the adsorption of anionic analytes. The nanohybrids (AuNRs/NMPs) exhibit a 3D hotspot effect due to self‐assembly and feature regularly arranged AuNRs, thus enabling Raman signal enhancement and sensitive (limit of detection (LOD) = 10−9 m, Raman enhancement factor (EF) = 2.0 × 108) and reproducible (relative standard deviation (RSD) = 8.82%) adenine detection based on surface‐enhanced Raman scattering (SERS). …”
    Get full text
    Article
  17. 257

    Recent advances in the design of SERS substrates and sensing systems for (bio)sensing applications: Systems from single cell to single molecule detection [version 2; peer review: 2... by Pooja Nag, Kapil Sadani, Sreelakshmi C S, Chiranjay Mukhopadhyay, Anirudh Bharadwaj, Ashwini G Shenoy, Sai Ratnakar Tadi

    Published 2025-03-01
    “…The advancements in these technologies have been reviewed and critiqued for analyte detection in resource-limited settings, highlighting the prospects of applications ranging from single-molecule to single-cell detection. …”
    Get full text
    Article
  18. 258

    Affordable droplet-based flow analyzer with peristaltic micro-pumps for fluorescent ammonium sensing by Mingtao Sun, Yiyu Jiang, Wenshan Liang, Hui Zeng, Huiwen Chen, Min Zhang

    Published 2024-12-01
    “…The analyzer provides a limit of detection of 0.02 μM (3σ) and an RSD of 0.15 % (n=10, 1 μM ammonium). …”
    Get full text
    Article
  19. 259
  20. 260

    Quantifying Post-Purchase Service Satisfaction: A Topic–Emotion Fusion Approach with Smartphone Data by Peijun Guo, Huan Li, Xinyue Mo

    Published 2025-05-01
    “…The filtered genuine reviews are then analyzed using Biterm Topic Modeling (BTM) to extract key satisfaction-related topics, which are weighted based on sentiment scores and organized into a multi-criteria evaluation matrix through the Analytic Hierarchy Process (AHP). These topics are further clustered into five major factors: user-centered design (70.8%), core performance (10.0%), imaging features (8.6%), promotional incentives (7.8%), and industrial design (2.8%). …”
    Get full text
    Article