-
81
Electrochemical Analysis of Carbon-Based Supercapacitors Using Finite Element Modeling and Impedance Spectroscopy
Published 2025-03-01“…For FEM, we used a volume-averaged approach to study the effect of the electrode structure on the EIS response of the cells. …”
Get full text
Article -
82
Cost-Effective Bimetallic Catalysts for Green H<sub>2</sub> Production in Anion Exchange Membrane Water Electrolyzers
Published 2025-07-01“…Electrochemical testing reveals that phase purity and average crystal size significantly influence cell performance. …”
Get full text
Article -
83
A novel personal identification system using doorknob lead electrocardiograms for unconscious authentication in unlocking doors
Published 2025-06-01“…In our previous study, it was shown that ECG obtained with a contact-type electrode on doorknob and a capacitive-type electrode on the floor could be used for personal identification. …”
Get full text
Article -
84
Comparison of different methods of determination of total fluoride content in soil
Published 2003-01-01“…The standard curve method, TISAB standard additions method, and perchloric acid standard additions method were described for the determination of total fluoride in soil using fluoride ion-selective electrode. TISAB standard additions method gave highest average recovery of 96.8% (ranging 86.9%-102.3%) among three methods. …”
Get full text
Article -
85
Electrochemical probe for total determination and speciation of selenium (IV& VI) species in water, drug formulations and foodstuffs using Thoron–I as selective chelating agent
Published 2025-07-01“…The probe was validated by analysis of selenium in certified reference material (CRM, IAEA- Soil-7) and in drug formulations. The average recoveries for the spiked water samples were ranged from 99.4 ± 0.60 to 110.0 ± 6.3. …”
Get full text
Article -
86
Simultaneous Detection of Neural Activity and Temperature in Photothermal Neural Stimulation
Published 2025-05-01“…Using this multifunctional system, it is demonstrated that an average increase of 2.34 °C at neuronal cell surfaces results in over 95% suppression of hippocampal neural spike activities. …”
Get full text
Article -
87
An empirical investigation into enhancing natural convection heat transfer through corona wind in a needle-to-cylinder configuration
Published 2025-04-01“…Among these, the single lateral electrode configuration demonstrated superior performance, yielding a 13.87 % higher average Nusselt number than the vertical electrode configuration. …”
Get full text
Article -
88
The Observation of Performance Trends by Numerical Simulation with Different Parameters in a Nonlinear Reversible Solid Oxide Cell System
Published 2024-12-01“…The design parameters related to the electrode microstructure are defined in this model as: porosity (electrode porosity), pore size (electrode internal average pore size), and permeability (electrode internal permeability).…”
Get full text
Article -
89
Comparisons of computer simulations and experimental data for capacitive hyperthermia using different split-phantoms
Published 2024-12-01“…In terms of point-to-point absolute SAR comparison (without any normalization), up to a depth of 11 cm in the phantoms central vertical plot, the simulation differs from the measured TR points by on average 25% (ranging from 7% to 36%) for the homogeneous phantom and by on average 43% (ranging from 26% to 60%) for the inhomogeneous phantom.Conclusion Computer simulations and experimental data were compared for the CHT system EHY-2030 using the D200 electrode, applying a thermal imaging technique for different vertically splittable phantoms. …”
Get full text
Article -
90
Breakdown Characteristics of Propylene Carbonate and Deionized Water Under Nanosecond Pulsed Voltages
Published 2025-03-01“…The results indicate that the breakdown voltages of both PC and DI water increase almost linearly with the electrode gap, whereas the average breakdown field strength decreases exponentially as the electrode gap widens. …”
Get full text
Article -
91
THE TWO PARAMETER SENSORS OF THE LIQUID LEVEL
Published 2015-04-01“…The sensors contains three cylindrical electrodes of unequal length. The potential of an average electrode varies. …”
Get full text
Article -
92
Optimization and Evaluation of Electrostatic Spraying Systems and Their Effects on Pesticide Deposition and Coverage Inside Dense Canopy Plants
Published 2025-06-01“…The nozzles operated with the optimized electrode had average improvements in the canopy deposition and canopy coverage of 1.33 µg cm<sup>−2</sup> and 4.4% at a wind speed of 0 m s<sup>−1</sup> and 0.26 µg cm<sup>−2</sup> and 0.9% at a wind speed of 2.24 m s<sup>−1</sup>. …”
Get full text
Article -
93
Analysis and Process Optimization on Hydrogen Content by Electroslag Remelting of Steel 316H for Nuclear Power
Published 2025-02-01“…When the initial hydrogen of the electrode is greater than 4×10-6, the electroslag remelting process will appear dehydrogenation.After the process optimization, the average qualified rate of hydrogen reaches 97.5%, which is 2.8% higher than 94.7% before the optimization.…”
Get full text
Article -
94
Development of a Printed Sensor and Wireless Measurement System for Urination Monitoring
Published 2025-05-01“…The ultrathin design of the sensor electrode, with an average thickness of only 30 microns, ensures both user comfort and measurement accuracy. …”
Get full text
Article -
95
Bunch of Grape-Like Shape PANI/Ag2O/Ag Nanocomposite Photocatalyst for Hydrogen Generation from Wastewater
Published 2022-01-01“…The PANI/Ag2O/Ag composite II has the optimum optical properties, in which the bandgaps of PANI, composite I, and composite II are 3.02, 1.71, and 1.68 eV, respectively, with the morphology of a bunch of grape-like shapes with average particles sizes of 25 nm. Under the optimum optical properties, glass/PANI/Ag2O/Ag composite II electrode is used for hydrogen generation from sewage water. …”
Get full text
Article -
96
THE EFFECT OF SYNTHETIC ZEOLITES ON SENSITIVITY AND STABILITY OF URIC ACID BIOSENSOR USING CYCLE VOLTAMETRY METHOD
Published 2018-12-01“…In each electrode, 7.5 μl of L.plantarum pellet (EPKZLP) was dropped. …”
Get full text
Article -
97
Impedance Characteristics of Pulsed Atmospheric Electrical Discharge in Spherical Plasma Switch
Published 2011-06-01“…Typical damage patterns were observed with average diameters of up to 8.3 mm on the high voltage electrode and 10.5 mm on the grounded sphere resulting from accumulative discharges and power dissipation within the gap.…”
Get full text
Article -
98
Exploring cortical excitability in children with cerebral palsy through lower limb robot training based on MI-BCI
Published 2025-04-01“…In the δ and γ frequency bands, MI and MI-BCI both had greater inter-electrode connectivity strength than REST. In the θ frequency band, REST had greater inter-electrode connectivity strength than MI-BCI, while MI-BCI had greater inter-electrode connectivity strength than both REST and MI. …”
Get full text
Article -
99
Thermoelectric Effect of Buckypaper/Copper Assembly
Published 2019-01-01“…Finally, an average Seebeck coefficient for the BP/copper electrodes array of 35.34 ± 6.0 mV/K was estimated from 298 to 304 K. …”
Get full text
Article -
100
Investigating the effect of cochlear implant usage metrics on cortical auditory-evoked potential responses in adult recipients post-implantation
Published 2024-11-01“…CI usage frequency was defined as the average number of hours per day of audio processor use, which was recorded using the CI programming software.ResultsOverall, 27 participants (65.85%) exhibited detectable eCAEP responses across one or more electrode contacts. …”
Get full text
Article