-
3181
Accelerated Predictive Stability Testing: Accelerating Registration Phase and Application of Reduced Designs for Shelf-Life Determination of Parenteral Drug Product
Published 2025-01-01“…In contrast, ASAP provides an efficient approach to support drug product development and expedite regulatory procedures. …”
Get full text
Article -
3182
Validity of ICD-10-CM codes for determination of diabetes type for persons with youth-onset type 1 and type 2 diabetes
Published 2019-05-01“…We assessed the validity of International Classification of Disease, 10th Revision, Clinical Modification (ICD-10-CM) codes to discriminate between type 1 diabetes mellitus (T1DM) and type 2 diabetes mellitus (T2DM) among health plan members with youth-onset (diagnosis age <20 years) diabetes.Research design and methods . Diabetes case identification and abstraction of diabetes type was done as part of the SEARCH for Diabetes in Youth Study. …”
Get full text
Article -
3183
Determination of the Activity Coefficients of Components in a Di-2-ethylhexylphosphoric Acid–n-Hexane Binary System Using Gas Chromatography
Published 2025-06-01“…This study was devoted to the determination of n-hexane’s concentrations in the vapor phase over D2EHPA solutions at 293.0 K using gas chromatography (GC) and isopiestic (IP) methods. …”
Get full text
Article -
3184
-
3185
Salting-Out Assisted Liquid-Liquid Extraction of Cr (VI) from Water Samples before Its Determination by UV-Vis Spectrophotometry
Published 2023-01-01“…This paper proposes salting-out assisted liquid-liquid extraction for selective extraction of a Cr (VI)-1,5-diphenylcarbazide complex before its determination by UV-Vis spectrophotometry. Parameters affecting the complexation process and the extraction efficiency of the method were studied. …”
Get full text
Article -
3186
The Determinants of Delays and Their Impact on Clinical End Points in Acute ST-Segment Elevation Myocardial Infarction: A Single-Center Experience
Published 2025-03-01“…In addition, the effect of this delay on the patient’s prognosis has also been investigated. <i>Materials and Methods</i>: a total of 301 patients diagnosed with STEMI treated with primary percutaneous coronary intervention (pPCI) were included in the study. …”
Get full text
Article -
3187
Determination of Trace Rare Earth Elements in Tungsten-Molybdenum Ore by Inductively Coupled Plasma-Mass Spectrometry with Microwave Digestion System
Published 2023-08-01“…During the pretreatment of tungsten and molybdenum ore samples, the alkali melting flux will introduce the salt matrix, and the tungsten and molybdenum elements in an acid dissolution condition are easy to hydrolyze into tungstic acid and molybdic acid and produce rare earth fluoride.OBJECTIVESTo establish an analytical method for accurate determination of the 16 rare earth elements including La, Ce, Pr, Nd, Sm, Eu, Gd, Tb, Dy, Ho, Er, Tm, Yb, Lu, Y, and Sc, in tungsten-molybdenum ore by inductively coupled plasma-mass spectrometry (ICP-MS).METHODSTungsten-molybdenum ore samples were fast digested by microwave with four acid system (HNO3-HF-HClO4-HCl) in a high temperature and high-pressure environment. …”
Get full text
Article -
3188
Tumor-infiltrating lymphocytes are the key determinants of pathological features associated with pathogenic BRCA variants in high-grade serous ovarian carcinoma
Published 2025-06-01“…This approach is especially useful in resource-limited settings and can enhance diagnostic efficiency and clinical decision-making.…”
Get full text
Article -
3189
-
3190
Determination of Tungsten, Molybdenum and 5 Associated Elements in Tungsten-Molybdenum Ore by Inductively Coupled Plasma-Optical Emission Spectrometry with Direct Sintering
Published 2023-10-01“…It is insoluble in hydrochloric acid, nitric acid and aqua regia, and the alkali melting and mixed acid dissolution method was often selected for sample digestion. However, the matrix effect cause by the alkali melting method seriously affects the accuracy and detection limit of instrument testing; the acid dissolution method has low dissolution efficiency for tungsten, molybdenum and other insoluble elements, and requires a long time and a complex pretreatment process by using a variety of inorganic strong acids such as hydrofluoric acid and aqua regia, which can also cause damage to the analytical and testing instruments.OBJECTIVESTo develop a simple and efficient method for quantitative analysis of tungsten and molybdenum and its associated elements in tungsten-molybdenum ore.METHODSBased on alkaline melting and acid dissolution, a method was established by inductively coupled plasma-optical emission spectrometry (ICP-OES) with direct sintering and complex extraction of hydrochloric acid-phosphoric acid-citric acid. …”
Get full text
Article -
3191
Simultaneous determination of 9 succinate dehydrogenase inhibitor compounds in vegetables by QuEChERS combined with gas chromatography-tandem mass spectrometry
Published 2025-04-01“…The results of different levels of spiked experiments for 9 SDHIs showed a good recovery rate of 80.4%-98.2% and the relative standard deviations (RSDs) were 3.0%-7.9%. The method was efficient, fast, easy to operate, with low detection cost, high recovery rate, high sensitivity, and good reproducibility, which was suitable for batch determination of 9 SDHIs in daily vegetables.…”
Get full text
Article -
3192
Microwave-assisted synthesis of antimony oxide nanoparticles for the determination of trace cadmium in mulberry leaf tea matrices by flame atomic absorption spectrophotometry
Published 2024-12-01“…Abstract In this study, a rapid, sensitive and accurate analytical method was optimized for the determination of trace levels of cadmium (Cd) by flame atomic absorption spectrophotometry (FAAS) after antimony oxide nanoparticles (AO-NPs)-based dispersive solid-phase extraction (DSPE). …”
Get full text
Article -
3193
QuEChERS combined with ultra-high performance liquid chromatography-tandem mass spectrometry to determine acrylamide in Xinjiang Naan products
Published 2024-11-01“…ObjectiveThis study aimed to establish a rapid and accurate analytical method for the determination of acrylamide in Xinjiang characteristic Naan products.MethodsThe methodology involved adding the internal standard 13C3-acrylamide isotope to the samples, followed by the sequential addition of 9 mL of water, 10 mL of acetonitrile, 6 mL of n-hexane, 6 g of anhydrous magnesium sulfate, and 1.5 g of sodium acetate salting agent. …”
Get full text
Article -
3194
Determination of 17 types of phthalates in drinking water by solid-phase extraction coupled with multiple reaction monitoring of gas chromatography-mass spectrometry
Published 2025-01-01“…The precision and accuracy of this method were assessed by determining the standard curves, detection limits, quantification limits, relative standard deviations (RSD) and average spiked recovery rates for the 17 types of PAEs. …”
Get full text
Article -
3195
-
3196
-
3197
Novel gas-diffusion microextraction followed by gas chromatography coupled to tandem mass spectrometry methodology for the determination of fragrance allergens in cosmetic products
Published 2025-05-01“…An efficient sample preparation method using gas-diffusion microextraction (GDME) followed by gas chromatography coupled to tandem mass spectrometry (GC-MS/MS) is proposed for the first time to determine fragrance allergens in both aqueous and alcohol-based cosmetic products. …”
Get full text
Article -
3198
-
3199
Development and validation of an open-source virtual reality environment for alcohol use disorder and determinants of cue-induced craving among Indian participants
Published 2025-07-01“…Virtual reality (VR) has allowed for efficient conducting of CE. Limited research exists on VR for AUD in Indian settings. …”
Get full text
Article -
3200
Determination of 15 Rare Earth Elements in Phosphate Ores by Inductively Coupled Plasma-Mass Spectrometry with Atmospheric Pressure Closed Microwave Digestion
Published 2024-04-01“…Microwave digestion directly releases energy to the sample with high efficiency, and volatile elements are retained in the digestion solution to prevent volatilization from causing deviation of results and environmental pollution. …”
Get full text
Article