Análisis inmunofenotípico de muestras normales de médula ósea: aplicaciones en el control de calidad en los laboratorios de citometría

Immunophenotypic analysis of normal cell samples from bone marrow: applications in quality control of cytometry laboratories.Objective. To describe a standardized flow cytometry protocol for the relative and absolute quantification of hematopoietic cell subpopulationsfrom normal bone marrow, and to...

Full description

Saved in:
Bibliographic Details
Main Authors: Dian Carolina Roa-Higuera, Susana Fiorentino, Viviana Marcela Rodriguez-Pardo, Alba Myriam Campos-Arenas, Elvira Antonia Infante-Acosta, Claudia Cecilia Cardozo-Romero, Sandra Milena Quijano-Gómez
Format: Article
Language:English
Published: Pontificia Universidad Javeriana 2010-12-01
Series:Universitas Scientiarum
Subjects:
Online Access:http://revistas.javeriana.edu.co/index.php/scientarium/article/view/1356/823
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850227979325538304
author Dian Carolina Roa-Higuera
Susana Fiorentino
Viviana Marcela Rodriguez-Pardo
Alba Myriam Campos-Arenas
Elvira Antonia Infante-Acosta
Claudia Cecilia Cardozo-Romero
Sandra Milena Quijano-Gómez
author_facet Dian Carolina Roa-Higuera
Susana Fiorentino
Viviana Marcela Rodriguez-Pardo
Alba Myriam Campos-Arenas
Elvira Antonia Infante-Acosta
Claudia Cecilia Cardozo-Romero
Sandra Milena Quijano-Gómez
author_sort Dian Carolina Roa-Higuera
collection DOAJ
description Immunophenotypic analysis of normal cell samples from bone marrow: applications in quality control of cytometry laboratories.Objective. To describe a standardized flow cytometry protocol for the relative and absolute quantification of hematopoietic cell subpopulationsfrom normal bone marrow, and to evaluate the expression of different lineage-specific cell markers with a reactivity associated to celldifferentiation to be used as part of the routine quality control in cytometry laboratories. Materials and methods. The immunophenotypicalanalysis of different cell subpopulations was done with samples from normal bone marrow using a panel of monoclonal and polyclonalantibodies useful in the characterization of acute leukemias with four different fluorescences, by means of a protocol that combines celllabeling of membrane and cytoplasm antigens. Expression analysis was done in terms of mean fluorescence intensity (MFI). Fluorescentbeads at a known concentration were added for calculating the absolute count of cells. Results. The antibody panel used allowed theidentification and quantification of different normal leukocyte subpopulations of lymphatic and myeloid origin, including CD34+ stem cells and more differentiated cell populations in the granulocytic, monocytic, and erythroid cell lines. We established reference values for cellpopulations and cell marker expression ranges as part of routine quality control of cytometry laboratories. Conclusion. Immunophenotypicpatterns identified as well as absolute and relative reference values for the different normal leukocyte populations from bone marrow can beused by cytometry laboratories as a basis for establishing reference parameters in phenotypic analyses of hematologic neoplasia.
format Article
id doaj-art-fe16dd435c2c42229b5fa528c16e67ff
institution OA Journals
issn 0122-7483
2027-1352
language English
publishDate 2010-12-01
publisher Pontificia Universidad Javeriana
record_format Article
series Universitas Scientiarum
spelling doaj-art-fe16dd435c2c42229b5fa528c16e67ff2025-08-20T02:04:40ZengPontificia Universidad JaverianaUniversitas Scientiarum0122-74832027-13522010-12-01153206223Análisis inmunofenotípico de muestras normales de médula ósea: aplicaciones en el control de calidad en los laboratorios de citometríaDian Carolina Roa-HigueraSusana FiorentinoViviana Marcela Rodriguez-PardoAlba Myriam Campos-ArenasElvira Antonia Infante-AcostaClaudia Cecilia Cardozo-RomeroSandra Milena Quijano-GómezImmunophenotypic analysis of normal cell samples from bone marrow: applications in quality control of cytometry laboratories.Objective. To describe a standardized flow cytometry protocol for the relative and absolute quantification of hematopoietic cell subpopulationsfrom normal bone marrow, and to evaluate the expression of different lineage-specific cell markers with a reactivity associated to celldifferentiation to be used as part of the routine quality control in cytometry laboratories. Materials and methods. The immunophenotypicalanalysis of different cell subpopulations was done with samples from normal bone marrow using a panel of monoclonal and polyclonalantibodies useful in the characterization of acute leukemias with four different fluorescences, by means of a protocol that combines celllabeling of membrane and cytoplasm antigens. Expression analysis was done in terms of mean fluorescence intensity (MFI). Fluorescentbeads at a known concentration were added for calculating the absolute count of cells. Results. The antibody panel used allowed theidentification and quantification of different normal leukocyte subpopulations of lymphatic and myeloid origin, including CD34+ stem cells and more differentiated cell populations in the granulocytic, monocytic, and erythroid cell lines. We established reference values for cellpopulations and cell marker expression ranges as part of routine quality control of cytometry laboratories. Conclusion. Immunophenotypicpatterns identified as well as absolute and relative reference values for the different normal leukocyte populations from bone marrow can beused by cytometry laboratories as a basis for establishing reference parameters in phenotypic analyses of hematologic neoplasia.http://revistas.javeriana.edu.co/index.php/scientarium/article/view/1356/823multiparametric flow cytometryimmunophenotypehematologic neoplasianormal bone marrowreference valuesquality control
spellingShingle Dian Carolina Roa-Higuera
Susana Fiorentino
Viviana Marcela Rodriguez-Pardo
Alba Myriam Campos-Arenas
Elvira Antonia Infante-Acosta
Claudia Cecilia Cardozo-Romero
Sandra Milena Quijano-Gómez
Análisis inmunofenotípico de muestras normales de médula ósea: aplicaciones en el control de calidad en los laboratorios de citometría
Universitas Scientiarum
multiparametric flow cytometry
immunophenotype
hematologic neoplasia
normal bone marrow
reference values
quality control
title Análisis inmunofenotípico de muestras normales de médula ósea: aplicaciones en el control de calidad en los laboratorios de citometría
title_full Análisis inmunofenotípico de muestras normales de médula ósea: aplicaciones en el control de calidad en los laboratorios de citometría
title_fullStr Análisis inmunofenotípico de muestras normales de médula ósea: aplicaciones en el control de calidad en los laboratorios de citometría
title_full_unstemmed Análisis inmunofenotípico de muestras normales de médula ósea: aplicaciones en el control de calidad en los laboratorios de citometría
title_short Análisis inmunofenotípico de muestras normales de médula ósea: aplicaciones en el control de calidad en los laboratorios de citometría
title_sort analisis inmunofenotipico de muestras normales de medula osea aplicaciones en el control de calidad en los laboratorios de citometria
topic multiparametric flow cytometry
immunophenotype
hematologic neoplasia
normal bone marrow
reference values
quality control
url http://revistas.javeriana.edu.co/index.php/scientarium/article/view/1356/823
work_keys_str_mv AT diancarolinaroahiguera analisisinmunofenotipicodemuestrasnormalesdemedulaoseaaplicacionesenelcontroldecalidadenloslaboratoriosdecitometria
AT susanafiorentino analisisinmunofenotipicodemuestrasnormalesdemedulaoseaaplicacionesenelcontroldecalidadenloslaboratoriosdecitometria
AT vivianamarcelarodriguezpardo analisisinmunofenotipicodemuestrasnormalesdemedulaoseaaplicacionesenelcontroldecalidadenloslaboratoriosdecitometria
AT albamyriamcamposarenas analisisinmunofenotipicodemuestrasnormalesdemedulaoseaaplicacionesenelcontroldecalidadenloslaboratoriosdecitometria
AT elviraantoniainfanteacosta analisisinmunofenotipicodemuestrasnormalesdemedulaoseaaplicacionesenelcontroldecalidadenloslaboratoriosdecitometria
AT claudiaceciliacardozoromero analisisinmunofenotipicodemuestrasnormalesdemedulaoseaaplicacionesenelcontroldecalidadenloslaboratoriosdecitometria
AT sandramilenaquijanogomez analisisinmunofenotipicodemuestrasnormalesdemedulaoseaaplicacionesenelcontroldecalidadenloslaboratoriosdecitometria