Design and analysis of a three-dimensional seismic isolation device for small modular reactor building

Seismic isolation in nuclear power plant (NPP) buildings has been infrequently applied using a rubber-based horizontal seismic isolation system (SIS) without vertical isolation under a peak ground acceleration (PGA) of 0.3 g as the seismic design requirement. For NPP buildings with seismic design re...

Full description

Saved in:
Bibliographic Details
Main Authors: Jae-Hong Kim, Jung-Dae Son, Yun-Ho Shin, Dae-Seung Cho
Format: Article
Language:English
Published: Elsevier 2025-12-01
Series:Nuclear Engineering and Technology
Subjects:
Online Access:http://www.sciencedirect.com/science/article/pii/S1738573325004061
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849229348060528640
author Jae-Hong Kim
Jung-Dae Son
Yun-Ho Shin
Dae-Seung Cho
author_facet Jae-Hong Kim
Jung-Dae Son
Yun-Ho Shin
Dae-Seung Cho
author_sort Jae-Hong Kim
collection DOAJ
description Seismic isolation in nuclear power plant (NPP) buildings has been infrequently applied using a rubber-based horizontal seismic isolation system (SIS) without vertical isolation under a peak ground acceleration (PGA) of 0.3 g as the seismic design requirement. For NPP buildings with seismic design requirements of PGA 0.5 g or greater, vertical seismic isolation has become an essential requirement to ensure the seismic protection of the systems, structures, and components (SSCs) inside the NPP, necessitating the development of feasible devices for a three-dimensional seismic isolation system (3D SIS). This study suggests a feasible device design for a 3D SIS capable of supporting a NuScale small modular reactor (SMR) building with a vertical load of 266,000 tf under a PGA seismic design requirement of 0.5 g. The performance of the designed 3D SIS in providing vertical and horizontal seismic isolation for the building is numerically examined. The proposed 3D SIS comprises 133 modularized 3D seismic isolation devices (3D SIDs) each with a vertical load capacity of 2000 tf, and dimensions of 3500 mm × 3500 mm, delivering natural frequencies of 1 and 0.3 Hz in vertical and horizontal directions, respectively. Viscous or friction damping devices are integrated into the 3D SID, designed to achieve vertical and horizontal damping ratios of at least 0.4 and 0.1, respectively, to reduce the peak acceleration response of the isolated target building to less than 0.3 g under the seismic input of 0.5 g PGA on the ground. The performance of the 3D SIS, constructed with the designed 3D SIDs for a target building, is validated through a full 3D numerical transient response analysis using ANSYS.
format Article
id doaj-art-fd1ceb13ba994e68bff8cd14aa5dd299
institution Kabale University
issn 1738-5733
language English
publishDate 2025-12-01
publisher Elsevier
record_format Article
series Nuclear Engineering and Technology
spelling doaj-art-fd1ceb13ba994e68bff8cd14aa5dd2992025-08-22T04:55:57ZengElsevierNuclear Engineering and Technology1738-57332025-12-01571210383810.1016/j.net.2025.103838Design and analysis of a three-dimensional seismic isolation device for small modular reactor buildingJae-Hong Kim0Jung-Dae Son1Yun-Ho Shin2Dae-Seung Cho3RMS Technology Co., Ltd., 55, Pungsesandan 1-ro, Pungse-myeon, Dongnam-gu, Cheonan-si, Chungcheongnam-do, 31217, Republic of KoreaDoosan Enerbility Co., Ltd., 22, DoosanVolvo-ro, Seongsan-gu, Changwon, Gyeongnam, 51711, Republic of KoreaDepartment of Naval Architecture & Ocean Engineering/GCRC, Pusan National University, 2, Busandaehak-ro 63beon-gil, Geumjeong-gu, Busan, 46241, Republic of Korea; Corresponding author.Department of Naval Architecture & Ocean Engineering/GCRC, Pusan National University, 2, Busandaehak-ro 63beon-gil, Geumjeong-gu, Busan, 46241, Republic of Korea; Corresponding author.Seismic isolation in nuclear power plant (NPP) buildings has been infrequently applied using a rubber-based horizontal seismic isolation system (SIS) without vertical isolation under a peak ground acceleration (PGA) of 0.3 g as the seismic design requirement. For NPP buildings with seismic design requirements of PGA 0.5 g or greater, vertical seismic isolation has become an essential requirement to ensure the seismic protection of the systems, structures, and components (SSCs) inside the NPP, necessitating the development of feasible devices for a three-dimensional seismic isolation system (3D SIS). This study suggests a feasible device design for a 3D SIS capable of supporting a NuScale small modular reactor (SMR) building with a vertical load of 266,000 tf under a PGA seismic design requirement of 0.5 g. The performance of the designed 3D SIS in providing vertical and horizontal seismic isolation for the building is numerically examined. The proposed 3D SIS comprises 133 modularized 3D seismic isolation devices (3D SIDs) each with a vertical load capacity of 2000 tf, and dimensions of 3500 mm × 3500 mm, delivering natural frequencies of 1 and 0.3 Hz in vertical and horizontal directions, respectively. Viscous or friction damping devices are integrated into the 3D SID, designed to achieve vertical and horizontal damping ratios of at least 0.4 and 0.1, respectively, to reduce the peak acceleration response of the isolated target building to less than 0.3 g under the seismic input of 0.5 g PGA on the ground. The performance of the 3D SIS, constructed with the designed 3D SIDs for a target building, is validated through a full 3D numerical transient response analysis using ANSYS.http://www.sciencedirect.com/science/article/pii/S1738573325004061Nuclear power plant (NPP)Nuscale small modular reactor buildingThree-dimensional seismic isolation systemThree-dimensional seismic isolation deviceLinear motion guide systemPeak ground acceleration
spellingShingle Jae-Hong Kim
Jung-Dae Son
Yun-Ho Shin
Dae-Seung Cho
Design and analysis of a three-dimensional seismic isolation device for small modular reactor building
Nuclear Engineering and Technology
Nuclear power plant (NPP)
Nuscale small modular reactor building
Three-dimensional seismic isolation system
Three-dimensional seismic isolation device
Linear motion guide system
Peak ground acceleration
title Design and analysis of a three-dimensional seismic isolation device for small modular reactor building
title_full Design and analysis of a three-dimensional seismic isolation device for small modular reactor building
title_fullStr Design and analysis of a three-dimensional seismic isolation device for small modular reactor building
title_full_unstemmed Design and analysis of a three-dimensional seismic isolation device for small modular reactor building
title_short Design and analysis of a three-dimensional seismic isolation device for small modular reactor building
title_sort design and analysis of a three dimensional seismic isolation device for small modular reactor building
topic Nuclear power plant (NPP)
Nuscale small modular reactor building
Three-dimensional seismic isolation system
Three-dimensional seismic isolation device
Linear motion guide system
Peak ground acceleration
url http://www.sciencedirect.com/science/article/pii/S1738573325004061
work_keys_str_mv AT jaehongkim designandanalysisofathreedimensionalseismicisolationdeviceforsmallmodularreactorbuilding
AT jungdaeson designandanalysisofathreedimensionalseismicisolationdeviceforsmallmodularreactorbuilding
AT yunhoshin designandanalysisofathreedimensionalseismicisolationdeviceforsmallmodularreactorbuilding
AT daeseungcho designandanalysisofathreedimensionalseismicisolationdeviceforsmallmodularreactorbuilding