Research on Energy Saving of Dual-loop Coupled Refrigerator with Two-stage Throttling

When a dual-loop coupled refrigerator operates in a coupled state, the condensation pressure of the freezing loop decreases, such that the refrigerant outlet of the condenser is not completely condensed. Hence, the cooling capacity provided by the freezing loop is used to treat the refrigerant that...

Full description

Saved in:
Bibliographic Details
Main Authors: 王亚聪, 唐黎明, 邬晗晖, 陈光明, 陈琪
Format: Article
Language:zho
Published: Journal of Refrigeration Magazines Agency Co., Ltd. 2023-01-01
Series:Zhileng xuebao
Subjects:
Online Access:http://www.zhilengxuebao.com/thesisDetails#10.3969/j.issn.0253-4339.2023.06.131
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850233013378482176
author 王亚聪
唐黎明
邬晗晖
陈光明
陈琪
author_facet 王亚聪
唐黎明
邬晗晖
陈光明
陈琪
author_sort 王亚聪
collection DOAJ
description When a dual-loop coupled refrigerator operates in a coupled state, the condensation pressure of the freezing loop decreases, such that the refrigerant outlet of the condenser is not completely condensed. Hence, the cooling capacity provided by the freezing loop is used to treat the refrigerant that is not completely condensed. It is therefore difficult for the system to take full advantage of the energy-saving ability of the design. To solve this problem, we propose a dual-loop coupled system with two-stage throttling. By adding a throttling expansion device between the freezing condenser and coupled subcooler, the system can operate stably. In this study, the refrigerant is R600a. Under the conditions of ambient temperature of 25 °C and freezer temperature of ?18 °C, we simulated the operating state of the system using Matlab, which was validated by an experimental device. The research results show that the system can maintain stability in both independent and coupled operations when the system works under the design conditions, and the coefficient of performance (COP) of the coupled operation is approximately 9% higher than that of the independent operation.
format Article
id doaj-art-fd16f883178741ab907ddf2bae7307a9
institution OA Journals
issn 0253-4339
language zho
publishDate 2023-01-01
publisher Journal of Refrigeration Magazines Agency Co., Ltd.
record_format Article
series Zhileng xuebao
spelling doaj-art-fd16f883178741ab907ddf2bae7307a92025-08-20T02:03:00ZzhoJournal of Refrigeration Magazines Agency Co., Ltd.Zhileng xuebao0253-43392023-01-014466500830Research on Energy Saving of Dual-loop Coupled Refrigerator with Two-stage Throttling王亚聪唐黎明邬晗晖陈光明陈琪When a dual-loop coupled refrigerator operates in a coupled state, the condensation pressure of the freezing loop decreases, such that the refrigerant outlet of the condenser is not completely condensed. Hence, the cooling capacity provided by the freezing loop is used to treat the refrigerant that is not completely condensed. It is therefore difficult for the system to take full advantage of the energy-saving ability of the design. To solve this problem, we propose a dual-loop coupled system with two-stage throttling. By adding a throttling expansion device between the freezing condenser and coupled subcooler, the system can operate stably. In this study, the refrigerant is R600a. Under the conditions of ambient temperature of 25 °C and freezer temperature of ?18 °C, we simulated the operating state of the system using Matlab, which was validated by an experimental device. The research results show that the system can maintain stability in both independent and coupled operations when the system works under the design conditions, and the coefficient of performance (COP) of the coupled operation is approximately 9% higher than that of the independent operation.http://www.zhilengxuebao.com/thesisDetails#10.3969/j.issn.0253-4339.2023.06.131compression refrigeration cycledual-loop coupledtwo-stage throttlingrefrigerator
spellingShingle 王亚聪
唐黎明
邬晗晖
陈光明
陈琪
Research on Energy Saving of Dual-loop Coupled Refrigerator with Two-stage Throttling
Zhileng xuebao
compression refrigeration cycle
dual-loop coupled
two-stage throttling
refrigerator
title Research on Energy Saving of Dual-loop Coupled Refrigerator with Two-stage Throttling
title_full Research on Energy Saving of Dual-loop Coupled Refrigerator with Two-stage Throttling
title_fullStr Research on Energy Saving of Dual-loop Coupled Refrigerator with Two-stage Throttling
title_full_unstemmed Research on Energy Saving of Dual-loop Coupled Refrigerator with Two-stage Throttling
title_short Research on Energy Saving of Dual-loop Coupled Refrigerator with Two-stage Throttling
title_sort research on energy saving of dual loop coupled refrigerator with two stage throttling
topic compression refrigeration cycle
dual-loop coupled
two-stage throttling
refrigerator
url http://www.zhilengxuebao.com/thesisDetails#10.3969/j.issn.0253-4339.2023.06.131
work_keys_str_mv AT wángyàcōng researchonenergysavingofdualloopcoupledrefrigeratorwithtwostagethrottling
AT tánglímíng researchonenergysavingofdualloopcoupledrefrigeratorwithtwostagethrottling
AT wūhánhuī researchonenergysavingofdualloopcoupledrefrigeratorwithtwostagethrottling
AT chénguāngmíng researchonenergysavingofdualloopcoupledrefrigeratorwithtwostagethrottling
AT chénqí researchonenergysavingofdualloopcoupledrefrigeratorwithtwostagethrottling