Seismic Assessment and Restoration Strategies for Cultural Heritage Buildings in the Neapolitan Area: The Case of Villa Vannucchi
Italy is internationally renowned for its cultural heritage, a testament to its rich history. Many of these structures, built before the advent of modern engineering principles, were constructed based on empirical knowledge and lack seismic design considerations, making them highly vulnerable to ear...
Saved in:
| Main Authors: | , |
|---|---|
| Format: | Article |
| Language: | English |
| Published: |
MDPI AG
2025-04-01
|
| Series: | Heritage |
| Subjects: | |
| Online Access: | https://www.mdpi.com/2571-9408/8/4/143 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| Summary: | Italy is internationally renowned for its cultural heritage, a testament to its rich history. Many of these structures, built before the advent of modern engineering principles, were constructed based on empirical knowledge and lack seismic design considerations, making them highly vulnerable to earthquakes. This vulnerability presents a significant challenge to preserving Italy’s architectural legacy. A notable example is Villa Vannucchi, located in the seismically active Vesuvius region. Given its historical and cultural significance, enhancing its structural resilience while preserving its architectural authenticity is imperative. This study investigates the seismic vulnerability of Villa Vannucchi through a comprehensive analysis of its structural deficiencies and proposes a targeted retrofitting strategy in accordance with the <i>Italian Guidelines for Cultural Heritage (IGCH)</i>. The evaluation is conducted in three phases: 1 Preliminary structural assessment—Calculation of two critical safety factors to evaluate the villa’s overall stability. 2 Local collapse mechanism analysis—Examination of the structure’s susceptibility to localized failures. 3 Advanced computational modelling—Detailed simulations revealing critically low seismic coefficients. Based on these findings, a consolidation plan is developed, integrating traditional and minimally invasive techniques. Key interventions include reinforcing the masonry and reducing floor deformability to improve overall structural stability. The implementation of these retrofitting measures significantly enhances the villa’s seismic resilience, as evidenced by the increased safety coefficients. This reduction in vulnerability not only ensures the preservation of Villa Vannucchi, but also safeguards its cultural and historical legacy for future generations. |
|---|---|
| ISSN: | 2571-9408 |