The Experimental Research on Refrigerant Mixtures of a Linde-Hampson Refrigeration System

The performance of quaternionic refrigerant mixtures, R345fa/R600a/R508b/R14, in Linde-Hampson refrigeration cycle was experimentally investigated. To get the lowest operation temperature, the components of refrigerant mixtures were optimized. The influence of ambient temperature on system operation...

Full description

Saved in:
Bibliographic Details
Main Authors: Zhu Juntao, Zhang Hua
Format: Article
Language:zho
Published: Journal of Refrigeration Magazines Agency Co., Ltd. 2012-01-01
Series:Zhileng xuebao
Subjects:
Online Access:http://www.zhilengxuebao.com/thesisDetails#10.3969/j.issn.0253-4339.2012.02.018
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:The performance of quaternionic refrigerant mixtures, R345fa/R600a/R508b/R14, in Linde-Hampson refrigeration cycle was experimentally investigated. To get the lowest operation temperature, the components of refrigerant mixtures were optimized. The influence of ambient temperature on system operational performance was analyzed. It is shown that the lowest system operation temperature could reach from -45℃ to -85℃ when mixing the four refrigerant components at different species ratio,. If the proportion of the refrigerant mixtures charged is R245fa:R600a:R508b:R14=0.45:0.3:0.18:0.07, the operating temperature of the system can reach -85℃ when the ambient temperature is 35℃. With the same refrigerant mixtures, the system temperature can reach -89.3℃ if the ambient temperature decreases from 35℃ to 5℃.