Abstract Industry applications of multi loop controller approaches are common because of their robustness, minimal tuning parameter, and straightforward design. A model based multi-loop predictive control method is presented. The proposed method directly uses the process model without approximation...
Saved in:
| Main Authors: | , , , , |
|---|---|
| Format: | Article |
| Language: | English |
| Published: |
Springer
2025-02-01
|
| Series: | Discover Applied Sciences |
| Subjects: | |
| Online Access: | https://doi.org/10.1007/s42452-025-06615-z |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| _version_ | 1849724057376784384 |
|---|---|
| author | Arun Ramaveerapathiran Muniraj Rathinam Karuppiah Natarajan Muthiah Athi Patil Mounica |
| author_facet | Arun Ramaveerapathiran Muniraj Rathinam Karuppiah Natarajan Muthiah Athi Patil Mounica |
| author_sort | Arun Ramaveerapathiran |
| collection | DOAJ |
| description | Abstract Industry applications of multi loop controller approaches are common because of their robustness, minimal tuning parameter, and straightforward design. A model based multi-loop predictive control method is presented. The proposed method directly uses the process model without approximation and reduction. A sequential relay based auto tuning procedure is applied for the tuning of the controller parameters. The efficacy of the suggested multi-loop control strategy is illustrated through comparative analysis and simulation. Simulation results show that the proposed method gives better response in terms of Integral Absolute Error value compared to multi-loop PI controller tuned by other methods. The proposed predictive method has IAE value of 28.9 whereas Biggest Log Modulus Tuning method has 55.34 for the Wood and Berry distillation column process. Alike, the proposed predictive method has IAE value of 350.26 whereas BLT method has 360.01 for the Orgunnaike and Ray distillation column process. In general, the multi-loop predictive PI scheme improves the overall performance. |
| format | Article |
| id | doaj-art-f7d7abcc60b34dd0b37b60f2eaf067d2 |
| institution | DOAJ |
| issn | 3004-9261 |
| language | English |
| publishDate | 2025-02-01 |
| publisher | Springer |
| record_format | Article |
| series | Discover Applied Sciences |
| spelling | doaj-art-f7d7abcc60b34dd0b37b60f2eaf067d22025-08-20T03:10:51ZengSpringerDiscover Applied Sciences3004-92612025-02-017311010.1007/s42452-025-06615-zModel based multi-loop predictive control scheme for multivariable processesArun Ramaveerapathiran0Muniraj Rathinam1Karuppiah Natarajan2Muthiah Athi3Patil Mounica4Department of Electrical and Electronics Engineering, Sri Sivasubramaniya Nadar College of EngineeringDepartment of Electrical and Electronics Engineering, P.S.R Engineering CollegeDepartment of Electrical and Electronics Engineering, Vardhaman College of EngineeringDepartment of Mechanical Engineering, P.S.R Engineering CollegeDepartment of Electrical and Electronics Engineering, Vardhaman College of EngineeringAbstract Industry applications of multi loop controller approaches are common because of their robustness, minimal tuning parameter, and straightforward design. A model based multi-loop predictive control method is presented. The proposed method directly uses the process model without approximation and reduction. A sequential relay based auto tuning procedure is applied for the tuning of the controller parameters. The efficacy of the suggested multi-loop control strategy is illustrated through comparative analysis and simulation. Simulation results show that the proposed method gives better response in terms of Integral Absolute Error value compared to multi-loop PI controller tuned by other methods. The proposed predictive method has IAE value of 28.9 whereas Biggest Log Modulus Tuning method has 55.34 for the Wood and Berry distillation column process. Alike, the proposed predictive method has IAE value of 350.26 whereas BLT method has 360.01 for the Orgunnaike and Ray distillation column process. In general, the multi-loop predictive PI scheme improves the overall performance.https://doi.org/10.1007/s42452-025-06615-zModel based controllerMulti-loop control schemeInternal model controller |
| spellingShingle | Arun Ramaveerapathiran Muniraj Rathinam Karuppiah Natarajan Muthiah Athi Patil Mounica Model based multi-loop predictive control scheme for multivariable processes Discover Applied Sciences Model based controller Multi-loop control scheme Internal model controller |
| title | Model based multi-loop predictive control scheme for multivariable processes |
| title_full | Model based multi-loop predictive control scheme for multivariable processes |
| title_fullStr | Model based multi-loop predictive control scheme for multivariable processes |
| title_full_unstemmed | Model based multi-loop predictive control scheme for multivariable processes |
| title_short | Model based multi-loop predictive control scheme for multivariable processes |
| title_sort | model based multi loop predictive control scheme for multivariable processes |
| topic | Model based controller Multi-loop control scheme Internal model controller |
| url | https://doi.org/10.1007/s42452-025-06615-z |
| work_keys_str_mv | AT arunramaveerapathiran modelbasedmultilooppredictivecontrolschemeformultivariableprocesses AT munirajrathinam modelbasedmultilooppredictivecontrolschemeformultivariableprocesses AT karuppiahnatarajan modelbasedmultilooppredictivecontrolschemeformultivariableprocesses AT muthiahathi modelbasedmultilooppredictivecontrolschemeformultivariableprocesses AT patilmounica modelbasedmultilooppredictivecontrolschemeformultivariableprocesses |