Improving efficiency of installation for disposal of oil-contaminated soil at low temperatures
The article discusses some features of the method of reagent encapsulation in conditions of negative temperatures. An installation layout has been created that makes temperature measurement of the encapsulated material in the process of reagent encapsulation. During the experiment, the duration...
Saved in:
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Omsk State Technical University, Federal State Autonoumos Educational Institution of Higher Education
2020-09-01
|
Series: | Омский научный вестник |
Subjects: | |
Online Access: | https://www.omgtu.ru/general_information/media_omgtu/journal_of_omsk_research_journal/files/arhiv/2020/4%20(172)/5-8%20%D0%A8%D1%82%D1%80%D0%B8%D0%BF%D0%BB%D0%B8%D0%BD%D0%B3%20%D0%9B.%20%D0%9E.,%20%D0%A5%D0%BE%D0%BB%D0%BA%D0%B8%D0%BD%20%D0%95.%20%D0%93.,%20%D0%9C%D0%B5%D1%80%D0%BA%D1%83%D0%BB%D0%BE%D0%B2%20%D0%92.%20%D0%92..pdf |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | The article discusses some features of the method of reagent
encapsulation in conditions of negative temperatures. An
installation layout has been created that makes temperature
measurement of the encapsulated material in the process of
reagent encapsulation. During the experiment, the duration of
maintaining the temperature necessary for preparing the next
portion is determined. A comparison is made of the methods
for supplying carbon dioxide to the installation during reagent
encapsulation. As a result of the experiment, a more profitable
way of supplying carbon dioxide to the installation is determined. |
---|---|
ISSN: | 1813-8225 2541-7541 |