Partial Discharge Localization of Gas-Insulated Switchgear via Electromagnetic Time Reversal Enhanced by Windowed Phase Spectrum Cross-Correlation Criterion

Partial discharge (PD) localization is one of the most crucial steps in the insulation assessment of gas-insulated switchgear (GIS) since it can help technicians identify defective components efficiently. Recently, a new PD localization method named electromagnetic time reversal (EMTR) has been deve...

Full description

Saved in:
Bibliographic Details
Main Authors: Zongyao Wang, Yuan Yan, Lei Jin, Zixing Xu, Shuangzan Ren, Yanliang He, Saike Yang, Hongjie Li
Format: Article
Language:English
Published: IEEE 2024-01-01
Series:IEEE Access
Subjects:
Online Access:https://ieeexplore.ieee.org/document/10816037/
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1841536219037564928
author Zongyao Wang
Yuan Yan
Lei Jin
Zixing Xu
Shuangzan Ren
Yanliang He
Saike Yang
Hongjie Li
author_facet Zongyao Wang
Yuan Yan
Lei Jin
Zixing Xu
Shuangzan Ren
Yanliang He
Saike Yang
Hongjie Li
author_sort Zongyao Wang
collection DOAJ
description Partial discharge (PD) localization is one of the most crucial steps in the insulation assessment of gas-insulated switchgear (GIS) since it can help technicians identify defective components efficiently. Recently, a new PD localization method named electromagnetic time reversal (EMTR) has been developed for GIS. The technique yields more accurate localization results than the conventional time-of-arrival and angle-of-arrival methods since it uses the three-dimensional structure information of GIS. However, the classical EMTR method analyzing individual sensor data independently suffers from the problems of multiple spurious solutions and noise interferences. Accordingly, this paper proposes an improved EMTR method for PD localization of GIS based on dual-sensor detection and phase spectrum cross-correlation analysis. The proposed method offers two improvements as follows: on the one hand, the problem of multiple spurious solutions is solved via the phase spectrum cross-correlation analysis between the electric field distributions in GIS stimulated by the two back-injected signals from the two sensors, respectively; on the other hand, a windowed phase spectrum cross-correlation approach is proposed to automatically select the frequency sub-bands with high signal-to-noise ratios for PD localization calculation, thus minimizing the influence of noise interferences. Finally, the feasibility and effectiveness of the proposed method are validated via the simulation experiment on a 110-kV GIS with a comprehensive comparison with state-of-the-art alternatives.
format Article
id doaj-art-f69f1459724347599b2a0a5b6addded6
institution Kabale University
issn 2169-3536
language English
publishDate 2024-01-01
publisher IEEE
record_format Article
series IEEE Access
spelling doaj-art-f69f1459724347599b2a0a5b6addded62025-01-15T00:02:06ZengIEEEIEEE Access2169-35362024-01-011219736319737510.1109/ACCESS.2024.352249910816037Partial Discharge Localization of Gas-Insulated Switchgear via Electromagnetic Time Reversal Enhanced by Windowed Phase Spectrum Cross-Correlation CriterionZongyao Wang0https://orcid.org/0009-0008-4819-0997Yuan Yan1https://orcid.org/0000-0001-9284-1584Lei Jin2Zixing Xu3Shuangzan Ren4Yanliang He5Saike Yang6https://orcid.org/0000-0003-0013-6744Hongjie Li7https://orcid.org/0000-0002-9546-8938State Key Laboratory of Electrical Insulation and Power Equipment, Xi’an Jiaotong University, Xi’an, ChinaState Key Laboratory of Electrical Insulation and Power Equipment, Xi’an Jiaotong University, Xi’an, ChinaState Key Laboratory of Electrical Insulation and Power Equipment, Xi’an Jiaotong University, Xi’an, ChinaState Key Laboratory of Electrical Insulation and Power Equipment, Xi’an Jiaotong University, Xi’an, ChinaPower Research Institute of State Grid Shaanxi Electric Power Company Ltd., Xi’an, ChinaPower Research Institute of State Grid Shaanxi Electric Power Company Ltd., Xi’an, ChinaChina State Grid Hebei Electric Power Research Institute, State Grid Hebei Electric Power Supply Company Ltd., Shijiazhuang, ChinaState Key Laboratory of Electrical Insulation and Power Equipment, Xi’an Jiaotong University, Xi’an, ChinaPartial discharge (PD) localization is one of the most crucial steps in the insulation assessment of gas-insulated switchgear (GIS) since it can help technicians identify defective components efficiently. Recently, a new PD localization method named electromagnetic time reversal (EMTR) has been developed for GIS. The technique yields more accurate localization results than the conventional time-of-arrival and angle-of-arrival methods since it uses the three-dimensional structure information of GIS. However, the classical EMTR method analyzing individual sensor data independently suffers from the problems of multiple spurious solutions and noise interferences. Accordingly, this paper proposes an improved EMTR method for PD localization of GIS based on dual-sensor detection and phase spectrum cross-correlation analysis. The proposed method offers two improvements as follows: on the one hand, the problem of multiple spurious solutions is solved via the phase spectrum cross-correlation analysis between the electric field distributions in GIS stimulated by the two back-injected signals from the two sensors, respectively; on the other hand, a windowed phase spectrum cross-correlation approach is proposed to automatically select the frequency sub-bands with high signal-to-noise ratios for PD localization calculation, thus minimizing the influence of noise interferences. Finally, the feasibility and effectiveness of the proposed method are validated via the simulation experiment on a 110-kV GIS with a comprehensive comparison with state-of-the-art alternatives.https://ieeexplore.ieee.org/document/10816037/Electromagnetic time reversal (EMTR)partial discharge (PD) localizationgas-insulated switchgear (GIS)cross-correlation
spellingShingle Zongyao Wang
Yuan Yan
Lei Jin
Zixing Xu
Shuangzan Ren
Yanliang He
Saike Yang
Hongjie Li
Partial Discharge Localization of Gas-Insulated Switchgear via Electromagnetic Time Reversal Enhanced by Windowed Phase Spectrum Cross-Correlation Criterion
IEEE Access
Electromagnetic time reversal (EMTR)
partial discharge (PD) localization
gas-insulated switchgear (GIS)
cross-correlation
title Partial Discharge Localization of Gas-Insulated Switchgear via Electromagnetic Time Reversal Enhanced by Windowed Phase Spectrum Cross-Correlation Criterion
title_full Partial Discharge Localization of Gas-Insulated Switchgear via Electromagnetic Time Reversal Enhanced by Windowed Phase Spectrum Cross-Correlation Criterion
title_fullStr Partial Discharge Localization of Gas-Insulated Switchgear via Electromagnetic Time Reversal Enhanced by Windowed Phase Spectrum Cross-Correlation Criterion
title_full_unstemmed Partial Discharge Localization of Gas-Insulated Switchgear via Electromagnetic Time Reversal Enhanced by Windowed Phase Spectrum Cross-Correlation Criterion
title_short Partial Discharge Localization of Gas-Insulated Switchgear via Electromagnetic Time Reversal Enhanced by Windowed Phase Spectrum Cross-Correlation Criterion
title_sort partial discharge localization of gas insulated switchgear via electromagnetic time reversal enhanced by windowed phase spectrum cross correlation criterion
topic Electromagnetic time reversal (EMTR)
partial discharge (PD) localization
gas-insulated switchgear (GIS)
cross-correlation
url https://ieeexplore.ieee.org/document/10816037/
work_keys_str_mv AT zongyaowang partialdischargelocalizationofgasinsulatedswitchgearviaelectromagnetictimereversalenhancedbywindowedphasespectrumcrosscorrelationcriterion
AT yuanyan partialdischargelocalizationofgasinsulatedswitchgearviaelectromagnetictimereversalenhancedbywindowedphasespectrumcrosscorrelationcriterion
AT leijin partialdischargelocalizationofgasinsulatedswitchgearviaelectromagnetictimereversalenhancedbywindowedphasespectrumcrosscorrelationcriterion
AT zixingxu partialdischargelocalizationofgasinsulatedswitchgearviaelectromagnetictimereversalenhancedbywindowedphasespectrumcrosscorrelationcriterion
AT shuangzanren partialdischargelocalizationofgasinsulatedswitchgearviaelectromagnetictimereversalenhancedbywindowedphasespectrumcrosscorrelationcriterion
AT yanlianghe partialdischargelocalizationofgasinsulatedswitchgearviaelectromagnetictimereversalenhancedbywindowedphasespectrumcrosscorrelationcriterion
AT saikeyang partialdischargelocalizationofgasinsulatedswitchgearviaelectromagnetictimereversalenhancedbywindowedphasespectrumcrosscorrelationcriterion
AT hongjieli partialdischargelocalizationofgasinsulatedswitchgearviaelectromagnetictimereversalenhancedbywindowedphasespectrumcrosscorrelationcriterion