Determination of the metabolites, eicosanoids derived from polyunsaturated fatty acids in Drosophila tissue with high performance liquid chromatography tandem mass spectrometry

Eicosanoids, which mediate various physiological and pathophysiological processes, are mainly formed from C20 polyunsaturated fatty acids (PUFAs) such as arachidonic acid (AA,20:4n-6) and eicosapentaenoic acid (EPA,20:5n - 3) through cyclooxygenases (COX), lipoxygenases (LOXs) and cytochrome P450 (C...

Full description

Saved in:
Bibliographic Details
Main Authors: TAN Liangliang, SHEN Lirong
Format: Article
Language:English
Published: Zhejiang University Press 2016-01-01
Series:浙江大学学报. 农业与生命科学版
Subjects:
Online Access:https://www.academax.com/doi/10.3785/j.issn.1008-9209.2015.03.232
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849247538991857664
author TAN Liangliang
SHEN Lirong
author_facet TAN Liangliang
SHEN Lirong
author_sort TAN Liangliang
collection DOAJ
description Eicosanoids, which mediate various physiological and pathophysiological processes, are mainly formed from C20 polyunsaturated fatty acids (PUFAs) such as arachidonic acid (AA,20:4n-6) and eicosapentaenoic acid (EPA,20:5n - 3) through cyclooxygenases (COX), lipoxygenases (LOXs) and cytochrome P450 (CYPs) pathways, including prostaglandins (PGs), thromboxanes (TXs) and the lipoxin/leukotriene family of eicosanoids such as hydroperoxyeicosatetraenoic acids (HPETEs), hydroxyeicosatetraenoic acids (HETEs), and epoxyeicosatrienoic acids (EETs). Vast knowledge of eicosanoids stems from works in mammals. Lipid signaling that complicates our understanding of fatty acid signaling is highly complex and fine-tuned in mammal species. Fortunately, the small genetic model Drosophila melanogaster is considered to be an ideal model to investigate the flexible nature of eicosanoids signaling pathways. However, it seems that Drosophila possess a special lipid metabolic system which is different from mammals. Thus, before studying the physiological mechanism of eicosanoids by using Drosophila, it is necessary to clarify its metabolic characteristics to C20 PUFAs based on the detection of eicosanoids in Drosophila. Therefore, this study is aimed to develop a high performance liquid chromatography tandem mass spectrometry (HPLC-MS/MS) method for the determination of eicosanoids in Drosophila.Fifteen metabolites of AA and EPA produced by human in COX, LOX and CYP pathway were chosen, and each pathway contained 1 or 2 metabolites as delegates to ensure the representative of the method. These eicosanoids included PGF<sub>2α</sub>, PGE<sub>2</sub>, PGF<sub>3α</sub>, PGE<sub>3</sub>, 15 (S)-HETE, LTB<sub>4</sub>, 15 (S)-HEPE,11 (12)-EET,20-HETE,17 (18)-EpETE,17,18-DiHETE,15 (S)-HpEPE,15 (S)-HpETE, PGH<sub>2</sub> and 5 (S)-HpETE, and PGE2-d<sub>4</sub>, 15 (S)-HETE-d<sub>8</sub> and 20-HETE-d<sub>6</sub> were used as internal standards. Samples were prepared by solid phase extraction and separated on an Endeavorsil<sup>TM</sup> C<sub>18</sub> column (100 mm × 2.1 mm,1.8 μm). The analytes were detected by using multiple reaction monitoring (MRM) in a negative electrospray ion mode. The HPLC-MS/MS method to analyze 15 selected eicosanoids in Drosophila qualitatively and quantitatively was established by optimizing the sample pretreatment and the detection conditions.It was found that the recoveries were significantly influenced by the pH of sample adjusted by 1 mol/L sodium acetate buffer containing 5% methanol, and the optimized pH was at 6. The response values of analytes separated on a mobile phase of ultrapure water with 0.1% formic acid-acetonitrile were higher than these of ultrapure water with 0.1% formic acid-methanol, ultrapure water-acetonitrile or ultrapure water-methanol. To reduce the matrix interference, the blank Drosophila matrix was used to prepare the standard working solution. Obtained results showed that the calibration curves were of good linearity for the 15 metabolites in the range of 2.5-100 ng/mL with the correlation coefficient (r) of 0.991. The limits of detection and quantitation were about 0.1-2.6 ng/g and 0.3-8.7 ng/g, respectively. Spiked recovery experiments showed that both recoveries (89.3%-111.5%) and relative standard deviations (1.0%-15.0%) met the requirements of analytical methods.In conclusion, our study has established a simple, specific and sensitive method that suitable for the determination of eicosanoids in Drosophila which serves an approach to clarify the metabolic characteristics of Drosophila to C20 PUFAs.
format Article
id doaj-art-f487ac7cbcc34f45b2a0898720bbc075
institution Kabale University
issn 1008-9209
2097-5155
language English
publishDate 2016-01-01
publisher Zhejiang University Press
record_format Article
series 浙江大学学报. 农业与生命科学版
spelling doaj-art-f487ac7cbcc34f45b2a0898720bbc0752025-08-20T03:58:11ZengZhejiang University Press浙江大学学报. 农业与生命科学版1008-92092097-51552016-01-014281610.3785/j.issn.1008-9209.2015.03.23210089209Determination of the metabolites, eicosanoids derived from polyunsaturated fatty acids in Drosophila tissue with high performance liquid chromatography tandem mass spectrometryTAN LiangliangSHEN LirongEicosanoids, which mediate various physiological and pathophysiological processes, are mainly formed from C20 polyunsaturated fatty acids (PUFAs) such as arachidonic acid (AA,20:4n-6) and eicosapentaenoic acid (EPA,20:5n - 3) through cyclooxygenases (COX), lipoxygenases (LOXs) and cytochrome P450 (CYPs) pathways, including prostaglandins (PGs), thromboxanes (TXs) and the lipoxin/leukotriene family of eicosanoids such as hydroperoxyeicosatetraenoic acids (HPETEs), hydroxyeicosatetraenoic acids (HETEs), and epoxyeicosatrienoic acids (EETs). Vast knowledge of eicosanoids stems from works in mammals. Lipid signaling that complicates our understanding of fatty acid signaling is highly complex and fine-tuned in mammal species. Fortunately, the small genetic model Drosophila melanogaster is considered to be an ideal model to investigate the flexible nature of eicosanoids signaling pathways. However, it seems that Drosophila possess a special lipid metabolic system which is different from mammals. Thus, before studying the physiological mechanism of eicosanoids by using Drosophila, it is necessary to clarify its metabolic characteristics to C20 PUFAs based on the detection of eicosanoids in Drosophila. Therefore, this study is aimed to develop a high performance liquid chromatography tandem mass spectrometry (HPLC-MS/MS) method for the determination of eicosanoids in Drosophila.Fifteen metabolites of AA and EPA produced by human in COX, LOX and CYP pathway were chosen, and each pathway contained 1 or 2 metabolites as delegates to ensure the representative of the method. These eicosanoids included PGF<sub>2α</sub>, PGE<sub>2</sub>, PGF<sub>3α</sub>, PGE<sub>3</sub>, 15 (S)-HETE, LTB<sub>4</sub>, 15 (S)-HEPE,11 (12)-EET,20-HETE,17 (18)-EpETE,17,18-DiHETE,15 (S)-HpEPE,15 (S)-HpETE, PGH<sub>2</sub> and 5 (S)-HpETE, and PGE2-d<sub>4</sub>, 15 (S)-HETE-d<sub>8</sub> and 20-HETE-d<sub>6</sub> were used as internal standards. Samples were prepared by solid phase extraction and separated on an Endeavorsil<sup>TM</sup> C<sub>18</sub> column (100 mm × 2.1 mm,1.8 μm). The analytes were detected by using multiple reaction monitoring (MRM) in a negative electrospray ion mode. The HPLC-MS/MS method to analyze 15 selected eicosanoids in Drosophila qualitatively and quantitatively was established by optimizing the sample pretreatment and the detection conditions.It was found that the recoveries were significantly influenced by the pH of sample adjusted by 1 mol/L sodium acetate buffer containing 5% methanol, and the optimized pH was at 6. The response values of analytes separated on a mobile phase of ultrapure water with 0.1% formic acid-acetonitrile were higher than these of ultrapure water with 0.1% formic acid-methanol, ultrapure water-acetonitrile or ultrapure water-methanol. To reduce the matrix interference, the blank Drosophila matrix was used to prepare the standard working solution. Obtained results showed that the calibration curves were of good linearity for the 15 metabolites in the range of 2.5-100 ng/mL with the correlation coefficient (r) of 0.991. The limits of detection and quantitation were about 0.1-2.6 ng/g and 0.3-8.7 ng/g, respectively. Spiked recovery experiments showed that both recoveries (89.3%-111.5%) and relative standard deviations (1.0%-15.0%) met the requirements of analytical methods.In conclusion, our study has established a simple, specific and sensitive method that suitable for the determination of eicosanoids in Drosophila which serves an approach to clarify the metabolic characteristics of Drosophila to C20 PUFAs.https://www.academax.com/doi/10.3785/j.issn.1008-9209.2015.03.232<italic>Drosophila</italic>polyunsaturated fatty acidsmetaboliteseicosanoidshigh performance liquid chromatography tandem mass spectrometry
spellingShingle TAN Liangliang
SHEN Lirong
Determination of the metabolites, eicosanoids derived from polyunsaturated fatty acids in Drosophila tissue with high performance liquid chromatography tandem mass spectrometry
浙江大学学报. 农业与生命科学版
<italic>Drosophila</italic>
polyunsaturated fatty acids
metabolites
eicosanoids
high performance liquid chromatography tandem mass spectrometry
title Determination of the metabolites, eicosanoids derived from polyunsaturated fatty acids in Drosophila tissue with high performance liquid chromatography tandem mass spectrometry
title_full Determination of the metabolites, eicosanoids derived from polyunsaturated fatty acids in Drosophila tissue with high performance liquid chromatography tandem mass spectrometry
title_fullStr Determination of the metabolites, eicosanoids derived from polyunsaturated fatty acids in Drosophila tissue with high performance liquid chromatography tandem mass spectrometry
title_full_unstemmed Determination of the metabolites, eicosanoids derived from polyunsaturated fatty acids in Drosophila tissue with high performance liquid chromatography tandem mass spectrometry
title_short Determination of the metabolites, eicosanoids derived from polyunsaturated fatty acids in Drosophila tissue with high performance liquid chromatography tandem mass spectrometry
title_sort determination of the metabolites eicosanoids derived from polyunsaturated fatty acids in drosophila tissue with high performance liquid chromatography tandem mass spectrometry
topic <italic>Drosophila</italic>
polyunsaturated fatty acids
metabolites
eicosanoids
high performance liquid chromatography tandem mass spectrometry
url https://www.academax.com/doi/10.3785/j.issn.1008-9209.2015.03.232
work_keys_str_mv AT tanliangliang determinationofthemetaboliteseicosanoidsderivedfrompolyunsaturatedfattyacidsindrosophilatissuewithhighperformanceliquidchromatographytandemmassspectrometry
AT shenlirong determinationofthemetaboliteseicosanoidsderivedfrompolyunsaturatedfattyacidsindrosophilatissuewithhighperformanceliquidchromatographytandemmassspectrometry