Estimating the Radiation Dose to the Fetus in Prophylactic Internal Iliac Artery Balloon Occlusion: Three Cases

Background. Although radiation exposure is of great concern to expecting patients, little information is available on the fetal radiation dose associated with prophylactic internal iliac artery balloon occlusion (IIABO). Here we estimated the fetal radiation dose associated with prophylactic IIABO i...

Full description

Saved in:
Bibliographic Details
Main Authors: Kentaro Kai, Tomohiro Hamada, Akitoshi Yuge, Hiro Kiyosue, Yoshihiro Nishida, Kaei Nasu, Hisashi Narahara
Format: Article
Language:English
Published: Wiley 2015-01-01
Series:Case Reports in Obstetrics and Gynecology
Online Access:http://dx.doi.org/10.1155/2015/170343
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832556580194746368
author Kentaro Kai
Tomohiro Hamada
Akitoshi Yuge
Hiro Kiyosue
Yoshihiro Nishida
Kaei Nasu
Hisashi Narahara
author_facet Kentaro Kai
Tomohiro Hamada
Akitoshi Yuge
Hiro Kiyosue
Yoshihiro Nishida
Kaei Nasu
Hisashi Narahara
author_sort Kentaro Kai
collection DOAJ
description Background. Although radiation exposure is of great concern to expecting patients, little information is available on the fetal radiation dose associated with prophylactic internal iliac artery balloon occlusion (IIABO). Here we estimated the fetal radiation dose associated with prophylactic IIABO in Caesarean section (CS). Cases. We report our experience with the IIABO procedure in three consecutive patients with suspected placenta previa/accreta. Fetal radiation dose measurements were conducted prior to each CS by using an anthropomorphic phantom. Based on the simulated value, we calculated the fetal radiation dose as the absorbed dose. We found that the fetal radiation doses ranged from 12.88 to 31.6 mGy. The fetal radiation dose during the prophylactic IIABOs did not exceed 50 mGy. Conclusion. The IIABO procedure could result in a very small increase in the risk of harmful effects to the fetus.
format Article
id doaj-art-f43871cd374b428fbd70795b143c0e45
institution Kabale University
issn 2090-6684
2090-6692
language English
publishDate 2015-01-01
publisher Wiley
record_format Article
series Case Reports in Obstetrics and Gynecology
spelling doaj-art-f43871cd374b428fbd70795b143c0e452025-02-03T05:44:57ZengWileyCase Reports in Obstetrics and Gynecology2090-66842090-66922015-01-01201510.1155/2015/170343170343Estimating the Radiation Dose to the Fetus in Prophylactic Internal Iliac Artery Balloon Occlusion: Three CasesKentaro Kai0Tomohiro Hamada1Akitoshi Yuge2Hiro Kiyosue3Yoshihiro Nishida4Kaei Nasu5Hisashi Narahara6Department of Obstetrics and Gynecology, Oita University Faculty of Medicine, Oita 879-5593, JapanDepartment of Radiology, Oita University Faculty of Medicine, Oita 879-5593, JapanDepartment of Obstetrics and Gynecology, Oita University Faculty of Medicine, Oita 879-5593, JapanDepartment of Radiology, Oita University Faculty of Medicine, Oita 879-5593, JapanDepartment of Obstetrics and Gynecology, Oita University Faculty of Medicine, Oita 879-5593, JapanDepartment of Obstetrics and Gynecology, Oita University Faculty of Medicine, Oita 879-5593, JapanDepartment of Obstetrics and Gynecology, Oita University Faculty of Medicine, Oita 879-5593, JapanBackground. Although radiation exposure is of great concern to expecting patients, little information is available on the fetal radiation dose associated with prophylactic internal iliac artery balloon occlusion (IIABO). Here we estimated the fetal radiation dose associated with prophylactic IIABO in Caesarean section (CS). Cases. We report our experience with the IIABO procedure in three consecutive patients with suspected placenta previa/accreta. Fetal radiation dose measurements were conducted prior to each CS by using an anthropomorphic phantom. Based on the simulated value, we calculated the fetal radiation dose as the absorbed dose. We found that the fetal radiation doses ranged from 12.88 to 31.6 mGy. The fetal radiation dose during the prophylactic IIABOs did not exceed 50 mGy. Conclusion. The IIABO procedure could result in a very small increase in the risk of harmful effects to the fetus.http://dx.doi.org/10.1155/2015/170343
spellingShingle Kentaro Kai
Tomohiro Hamada
Akitoshi Yuge
Hiro Kiyosue
Yoshihiro Nishida
Kaei Nasu
Hisashi Narahara
Estimating the Radiation Dose to the Fetus in Prophylactic Internal Iliac Artery Balloon Occlusion: Three Cases
Case Reports in Obstetrics and Gynecology
title Estimating the Radiation Dose to the Fetus in Prophylactic Internal Iliac Artery Balloon Occlusion: Three Cases
title_full Estimating the Radiation Dose to the Fetus in Prophylactic Internal Iliac Artery Balloon Occlusion: Three Cases
title_fullStr Estimating the Radiation Dose to the Fetus in Prophylactic Internal Iliac Artery Balloon Occlusion: Three Cases
title_full_unstemmed Estimating the Radiation Dose to the Fetus in Prophylactic Internal Iliac Artery Balloon Occlusion: Three Cases
title_short Estimating the Radiation Dose to the Fetus in Prophylactic Internal Iliac Artery Balloon Occlusion: Three Cases
title_sort estimating the radiation dose to the fetus in prophylactic internal iliac artery balloon occlusion three cases
url http://dx.doi.org/10.1155/2015/170343
work_keys_str_mv AT kentarokai estimatingtheradiationdosetothefetusinprophylacticinternaliliacarteryballoonocclusionthreecases
AT tomohirohamada estimatingtheradiationdosetothefetusinprophylacticinternaliliacarteryballoonocclusionthreecases
AT akitoshiyuge estimatingtheradiationdosetothefetusinprophylacticinternaliliacarteryballoonocclusionthreecases
AT hirokiyosue estimatingtheradiationdosetothefetusinprophylacticinternaliliacarteryballoonocclusionthreecases
AT yoshihironishida estimatingtheradiationdosetothefetusinprophylacticinternaliliacarteryballoonocclusionthreecases
AT kaeinasu estimatingtheradiationdosetothefetusinprophylacticinternaliliacarteryballoonocclusionthreecases
AT hisashinarahara estimatingtheradiationdosetothefetusinprophylacticinternaliliacarteryballoonocclusionthreecases