Seismometer Health Diagnosis Based on Cross Spectral Density Coherence Method in Indonesia Seismic Networks

Evaluation of seismometer health is crucial in accurately detecting earthquake and tsunami events. Currently, seismometer health evaluation is based solely on data quality unrelated to seismometer sensor performance. While seismometers are essential for tracking seismic activity, environmental facto...

Full description

Saved in:
Bibliographic Details
Main Authors: Miftahul Jannah, Risa Annisa, Adhi Harmoko Saputro, Titik Lestari
Format: Article
Language:English
Published: Universitas Negeri Jakarta 2024-12-01
Series:Spektra: Jurnal Fisika dan Aplikasinya
Subjects:
Online Access:https://journal.unj.ac.id/unj/index.php/spektra/article/view/49829
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850164466265620480
author Miftahul Jannah
Risa Annisa
Adhi Harmoko Saputro
Titik Lestari
author_facet Miftahul Jannah
Risa Annisa
Adhi Harmoko Saputro
Titik Lestari
author_sort Miftahul Jannah
collection DOAJ
description Evaluation of seismometer health is crucial in accurately detecting earthquake and tsunami events. Currently, seismometer health evaluation is based solely on data quality unrelated to seismometer sensor performance. While seismometers are essential for tracking seismic activity, environmental factors, aging components, and external interference can cause seismometers to function worse over time. This study presents a seismometer health diagnosis technique based on seismic signal analysis, including signal truncation, signal resampling, filtering, and deconvolution of instrument response. Then the proposed method of cross-spectral density coherence to extract seismometer sensor health indicators performed on two adjacent broadband seismic stations by analyzing the frequency domain with a maximum inter-station distance of 100 km. The data used are seismic signals recorded on three-component seismometers (North-South, East-West, Z-Vertical). The coherence value of cross-spectral density is used as an indicator to diagnose seismometer health. The proposed method was evaluated on a seismic network in Indonesia consisting of 88 stations and a teleseismic earthquake event in Honshu, Japan. The coherence values of almost all tested stations are above 0.8, which means good performance. The proposed method is suitable for analyzing the health of seismometers, especially in Indonesia.
format Article
id doaj-art-f296fbc0be2f4df0a75fde20b4b7397c
institution OA Journals
issn 2541-3384
2541-3392
language English
publishDate 2024-12-01
publisher Universitas Negeri Jakarta
record_format Article
series Spektra: Jurnal Fisika dan Aplikasinya
spelling doaj-art-f296fbc0be2f4df0a75fde20b4b7397c2025-08-20T02:21:58ZengUniversitas Negeri JakartaSpektra: Jurnal Fisika dan Aplikasinya2541-33842541-33922024-12-019317918810.21009/SPEKTRA.093.05250853Seismometer Health Diagnosis Based on Cross Spectral Density Coherence Method in Indonesia Seismic NetworksMiftahul Jannah0Risa Annisa1Adhi Harmoko Saputro2Titik Lestari3Department of Physics, Faculty of Mathematics and Natural Sciences, Universitas Indonesia, Depok 16424, IndonesiaDepartment of Physics, Faculty of Mathematics and Natural Sciences, Universitas Indonesia, Depok 16424, IndonesiaDepartment of Physics, Faculty of Mathematics and Natural Sciences, Universitas Indonesia, Depok 16424, IndonesiaMeteorological, Climatology and Geophysics Agency of Indonesia, Jakarta 10720, IndonesiaEvaluation of seismometer health is crucial in accurately detecting earthquake and tsunami events. Currently, seismometer health evaluation is based solely on data quality unrelated to seismometer sensor performance. While seismometers are essential for tracking seismic activity, environmental factors, aging components, and external interference can cause seismometers to function worse over time. This study presents a seismometer health diagnosis technique based on seismic signal analysis, including signal truncation, signal resampling, filtering, and deconvolution of instrument response. Then the proposed method of cross-spectral density coherence to extract seismometer sensor health indicators performed on two adjacent broadband seismic stations by analyzing the frequency domain with a maximum inter-station distance of 100 km. The data used are seismic signals recorded on three-component seismometers (North-South, East-West, Z-Vertical). The coherence value of cross-spectral density is used as an indicator to diagnose seismometer health. The proposed method was evaluated on a seismic network in Indonesia consisting of 88 stations and a teleseismic earthquake event in Honshu, Japan. The coherence values of almost all tested stations are above 0.8, which means good performance. The proposed method is suitable for analyzing the health of seismometers, especially in Indonesia.https://journal.unj.ac.id/unj/index.php/spektra/article/view/49829seismic instrumentation healthbroadband seismometerteleseismic earthquakecoherence cross-spectral density
spellingShingle Miftahul Jannah
Risa Annisa
Adhi Harmoko Saputro
Titik Lestari
Seismometer Health Diagnosis Based on Cross Spectral Density Coherence Method in Indonesia Seismic Networks
Spektra: Jurnal Fisika dan Aplikasinya
seismic instrumentation health
broadband seismometer
teleseismic earthquake
coherence cross-spectral density
title Seismometer Health Diagnosis Based on Cross Spectral Density Coherence Method in Indonesia Seismic Networks
title_full Seismometer Health Diagnosis Based on Cross Spectral Density Coherence Method in Indonesia Seismic Networks
title_fullStr Seismometer Health Diagnosis Based on Cross Spectral Density Coherence Method in Indonesia Seismic Networks
title_full_unstemmed Seismometer Health Diagnosis Based on Cross Spectral Density Coherence Method in Indonesia Seismic Networks
title_short Seismometer Health Diagnosis Based on Cross Spectral Density Coherence Method in Indonesia Seismic Networks
title_sort seismometer health diagnosis based on cross spectral density coherence method in indonesia seismic networks
topic seismic instrumentation health
broadband seismometer
teleseismic earthquake
coherence cross-spectral density
url https://journal.unj.ac.id/unj/index.php/spektra/article/view/49829
work_keys_str_mv AT miftahuljannah seismometerhealthdiagnosisbasedoncrossspectraldensitycoherencemethodinindonesiaseismicnetworks
AT risaannisa seismometerhealthdiagnosisbasedoncrossspectraldensitycoherencemethodinindonesiaseismicnetworks
AT adhiharmokosaputro seismometerhealthdiagnosisbasedoncrossspectraldensitycoherencemethodinindonesiaseismicnetworks
AT titiklestari seismometerhealthdiagnosisbasedoncrossspectraldensitycoherencemethodinindonesiaseismicnetworks