Types of hemodynamic response to orthostasis according to continuous blood pressure monitoring: a case series of heart failure with reduced ejection fraction

Heart failure (HF) is associated with unfavorable outcomes and high health care costs. Determination of the hemodynamic response to orthostasis can be an additional tool in assessing the stability and compensation of HF patients. Active orthostatic test (AOT) with blood pressure monitoring serves as...

Full description

Saved in:
Bibliographic Details
Main Authors: D. N. Fedorova, A. E. Solovieva, V. L. Galenko, A. V. Kozlenok, A. V. Berezina, S. V. Villevalde
Format: Article
Language:Russian
Published: «FIRMA «SILICEA» LLC 2021-10-01
Series:Российский кардиологический журнал
Subjects:
Online Access:https://russjcardiol.elpub.ru/jour/article/view/4574
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849250040321671168
author D. N. Fedorova
A. E. Solovieva
V. L. Galenko
A. V. Kozlenok
A. V. Berezina
S. V. Villevalde
author_facet D. N. Fedorova
A. E. Solovieva
V. L. Galenko
A. V. Kozlenok
A. V. Berezina
S. V. Villevalde
author_sort D. N. Fedorova
collection DOAJ
description Heart failure (HF) is associated with unfavorable outcomes and high health care costs. Determination of the hemodynamic response to orthostasis can be an additional tool in assessing the stability and compensation of HF patients. Active orthostatic test (AOT) with blood pressure monitoring serves as a simple and available screening method. However, a complete characteristic of the hemodynamic response, especially during the first minute of orthostasis, can be obtained only with continuous blood pressure monitoring. The presented case series demonstrate the types of hemodynamic response in patients with heart failure with reduced ejection fraction in AOT with continuous blood pressure monitoring, available data on the mechanisms of its development, clinical and prognostic role, and also presents the advantages and limitations of AOT.
format Article
id doaj-art-f27986b8263b42c58b53a472848733f7
institution Kabale University
issn 1560-4071
2618-7620
language Russian
publishDate 2021-10-01
publisher «FIRMA «SILICEA» LLC
record_format Article
series Российский кардиологический журнал
spelling doaj-art-f27986b8263b42c58b53a472848733f72025-08-20T03:57:22Zrus«FIRMA «SILICEA» LLCРоссийский кардиологический журнал1560-40712618-76202021-10-01263S10.15829/1560-4071-2021-45743346Types of hemodynamic response to orthostasis according to continuous blood pressure monitoring: a case series of heart failure with reduced ejection fractionD. N. Fedorova0A. E. Solovieva1V. L. Galenko2A. V. Kozlenok3A. V. Berezina4S. V. Villevalde5Almazov National Medical Research CenterAlmazov National Medical Research CenterAlmazov National Medical Research CenterAlmazov National Medical Research CenterAlmazov National Medical Research CenterAlmazov National Medical Research CenterHeart failure (HF) is associated with unfavorable outcomes and high health care costs. Determination of the hemodynamic response to orthostasis can be an additional tool in assessing the stability and compensation of HF patients. Active orthostatic test (AOT) with blood pressure monitoring serves as a simple and available screening method. However, a complete characteristic of the hemodynamic response, especially during the first minute of orthostasis, can be obtained only with continuous blood pressure monitoring. The presented case series demonstrate the types of hemodynamic response in patients with heart failure with reduced ejection fraction in AOT with continuous blood pressure monitoring, available data on the mechanisms of its development, clinical and prognostic role, and also presents the advantages and limitations of AOT.https://russjcardiol.elpub.ru/jour/article/view/4574heart failureactive orthostatic testcontinuous blood pressure monitoringorthostatic responseorthostatic hypotension
spellingShingle D. N. Fedorova
A. E. Solovieva
V. L. Galenko
A. V. Kozlenok
A. V. Berezina
S. V. Villevalde
Types of hemodynamic response to orthostasis according to continuous blood pressure monitoring: a case series of heart failure with reduced ejection fraction
Российский кардиологический журнал
heart failure
active orthostatic test
continuous blood pressure monitoring
orthostatic response
orthostatic hypotension
title Types of hemodynamic response to orthostasis according to continuous blood pressure monitoring: a case series of heart failure with reduced ejection fraction
title_full Types of hemodynamic response to orthostasis according to continuous blood pressure monitoring: a case series of heart failure with reduced ejection fraction
title_fullStr Types of hemodynamic response to orthostasis according to continuous blood pressure monitoring: a case series of heart failure with reduced ejection fraction
title_full_unstemmed Types of hemodynamic response to orthostasis according to continuous blood pressure monitoring: a case series of heart failure with reduced ejection fraction
title_short Types of hemodynamic response to orthostasis according to continuous blood pressure monitoring: a case series of heart failure with reduced ejection fraction
title_sort types of hemodynamic response to orthostasis according to continuous blood pressure monitoring a case series of heart failure with reduced ejection fraction
topic heart failure
active orthostatic test
continuous blood pressure monitoring
orthostatic response
orthostatic hypotension
url https://russjcardiol.elpub.ru/jour/article/view/4574
work_keys_str_mv AT dnfedorova typesofhemodynamicresponsetoorthostasisaccordingtocontinuousbloodpressuremonitoringacaseseriesofheartfailurewithreducedejectionfraction
AT aesolovieva typesofhemodynamicresponsetoorthostasisaccordingtocontinuousbloodpressuremonitoringacaseseriesofheartfailurewithreducedejectionfraction
AT vlgalenko typesofhemodynamicresponsetoorthostasisaccordingtocontinuousbloodpressuremonitoringacaseseriesofheartfailurewithreducedejectionfraction
AT avkozlenok typesofhemodynamicresponsetoorthostasisaccordingtocontinuousbloodpressuremonitoringacaseseriesofheartfailurewithreducedejectionfraction
AT avberezina typesofhemodynamicresponsetoorthostasisaccordingtocontinuousbloodpressuremonitoringacaseseriesofheartfailurewithreducedejectionfraction
AT svvillevalde typesofhemodynamicresponsetoorthostasisaccordingtocontinuousbloodpressuremonitoringacaseseriesofheartfailurewithreducedejectionfraction