Electrophysiology of Heart Failure Using a Rabbit Model: From the Failing Myocyte to Ventricular Fibrillation.

Heart failure is a leading cause of death, yet its underlying electrophysiological (EP) mechanisms are not well understood. In this study, we use a multiscale approach to analyze a model of heart failure and connect its results to features of the electrocardiogram (ECG). The heart failure model is d...

Full description

Saved in:
Bibliographic Details
Main Authors: Aditya V S Ponnaluri, Luigi E Perotti, Michael Liu, Zhilin Qu, James N Weiss, Daniel B Ennis, William S Klug, Alan Garfinkel
Format: Article
Language:English
Published: Public Library of Science (PLoS) 2016-06-01
Series:PLoS Computational Biology
Online Access:https://journals.plos.org/ploscompbiol/article/file?id=10.1371/journal.pcbi.1004968&type=printable
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849467687180173312
author Aditya V S Ponnaluri
Luigi E Perotti
Michael Liu
Zhilin Qu
James N Weiss
Daniel B Ennis
William S Klug
Alan Garfinkel
author_facet Aditya V S Ponnaluri
Luigi E Perotti
Michael Liu
Zhilin Qu
James N Weiss
Daniel B Ennis
William S Klug
Alan Garfinkel
author_sort Aditya V S Ponnaluri
collection DOAJ
description Heart failure is a leading cause of death, yet its underlying electrophysiological (EP) mechanisms are not well understood. In this study, we use a multiscale approach to analyze a model of heart failure and connect its results to features of the electrocardiogram (ECG). The heart failure model is derived by modifying a previously validated electrophysiology model for a healthy rabbit heart. Specifically, in accordance with the heart failure literature, we modified the cell EP by changing both membrane currents and calcium handling. At the tissue level, we modeled the increased gap junction lateralization and lower conduction velocity due to downregulation of Connexin 43. At the biventricular level, we reduced the apex-to-base and transmural gradients of action potential duration (APD). The failing cell model was first validated by reproducing the longer action potential, slower and lower calcium transient, and earlier alternans characteristic of heart failure EP. Subsequently, we compared the electrical wave propagation in one dimensional cables of healthy and failing cells. The validated cell model was then used to simulate the EP of heart failure in an anatomically accurate biventricular rabbit model. As pacing cycle length decreases, both the normal and failing heart develop T-wave alternans, but only the failing heart shows QRS alternans (although moderate) at rapid pacing. Moreover, T-wave alternans is significantly more pronounced in the failing heart. At rapid pacing, APD maps show areas of conduction block in the failing heart. Finally, accelerated pacing initiated wave reentry and breakup in the failing heart. Further, the onset of VF was not observed with an upregulation of SERCA, a potential drug therapy, using the same protocol. The changes introduced at the cell and tissue level have increased the failing heart's susceptibility to dynamic instabilities and arrhythmias under rapid pacing. However, the observed increase in arrhythmogenic potential is not due to a steepening of the restitution curve (not present in our model), but rather to a novel blocking mechanism.
format Article
id doaj-art-f215a631c14e4539a9d2a107fa41b34e
institution Kabale University
issn 1553-734X
1553-7358
language English
publishDate 2016-06-01
publisher Public Library of Science (PLoS)
record_format Article
series PLoS Computational Biology
spelling doaj-art-f215a631c14e4539a9d2a107fa41b34e2025-08-20T03:26:05ZengPublic Library of Science (PLoS)PLoS Computational Biology1553-734X1553-73582016-06-01126e100496810.1371/journal.pcbi.1004968Electrophysiology of Heart Failure Using a Rabbit Model: From the Failing Myocyte to Ventricular Fibrillation.Aditya V S PonnaluriLuigi E PerottiMichael LiuZhilin QuJames N WeissDaniel B EnnisWilliam S KlugAlan GarfinkelHeart failure is a leading cause of death, yet its underlying electrophysiological (EP) mechanisms are not well understood. In this study, we use a multiscale approach to analyze a model of heart failure and connect its results to features of the electrocardiogram (ECG). The heart failure model is derived by modifying a previously validated electrophysiology model for a healthy rabbit heart. Specifically, in accordance with the heart failure literature, we modified the cell EP by changing both membrane currents and calcium handling. At the tissue level, we modeled the increased gap junction lateralization and lower conduction velocity due to downregulation of Connexin 43. At the biventricular level, we reduced the apex-to-base and transmural gradients of action potential duration (APD). The failing cell model was first validated by reproducing the longer action potential, slower and lower calcium transient, and earlier alternans characteristic of heart failure EP. Subsequently, we compared the electrical wave propagation in one dimensional cables of healthy and failing cells. The validated cell model was then used to simulate the EP of heart failure in an anatomically accurate biventricular rabbit model. As pacing cycle length decreases, both the normal and failing heart develop T-wave alternans, but only the failing heart shows QRS alternans (although moderate) at rapid pacing. Moreover, T-wave alternans is significantly more pronounced in the failing heart. At rapid pacing, APD maps show areas of conduction block in the failing heart. Finally, accelerated pacing initiated wave reentry and breakup in the failing heart. Further, the onset of VF was not observed with an upregulation of SERCA, a potential drug therapy, using the same protocol. The changes introduced at the cell and tissue level have increased the failing heart's susceptibility to dynamic instabilities and arrhythmias under rapid pacing. However, the observed increase in arrhythmogenic potential is not due to a steepening of the restitution curve (not present in our model), but rather to a novel blocking mechanism.https://journals.plos.org/ploscompbiol/article/file?id=10.1371/journal.pcbi.1004968&type=printable
spellingShingle Aditya V S Ponnaluri
Luigi E Perotti
Michael Liu
Zhilin Qu
James N Weiss
Daniel B Ennis
William S Klug
Alan Garfinkel
Electrophysiology of Heart Failure Using a Rabbit Model: From the Failing Myocyte to Ventricular Fibrillation.
PLoS Computational Biology
title Electrophysiology of Heart Failure Using a Rabbit Model: From the Failing Myocyte to Ventricular Fibrillation.
title_full Electrophysiology of Heart Failure Using a Rabbit Model: From the Failing Myocyte to Ventricular Fibrillation.
title_fullStr Electrophysiology of Heart Failure Using a Rabbit Model: From the Failing Myocyte to Ventricular Fibrillation.
title_full_unstemmed Electrophysiology of Heart Failure Using a Rabbit Model: From the Failing Myocyte to Ventricular Fibrillation.
title_short Electrophysiology of Heart Failure Using a Rabbit Model: From the Failing Myocyte to Ventricular Fibrillation.
title_sort electrophysiology of heart failure using a rabbit model from the failing myocyte to ventricular fibrillation
url https://journals.plos.org/ploscompbiol/article/file?id=10.1371/journal.pcbi.1004968&type=printable
work_keys_str_mv AT adityavsponnaluri electrophysiologyofheartfailureusingarabbitmodelfromthefailingmyocytetoventricularfibrillation
AT luigieperotti electrophysiologyofheartfailureusingarabbitmodelfromthefailingmyocytetoventricularfibrillation
AT michaelliu electrophysiologyofheartfailureusingarabbitmodelfromthefailingmyocytetoventricularfibrillation
AT zhilinqu electrophysiologyofheartfailureusingarabbitmodelfromthefailingmyocytetoventricularfibrillation
AT jamesnweiss electrophysiologyofheartfailureusingarabbitmodelfromthefailingmyocytetoventricularfibrillation
AT danielbennis electrophysiologyofheartfailureusingarabbitmodelfromthefailingmyocytetoventricularfibrillation
AT williamsklug electrophysiologyofheartfailureusingarabbitmodelfromthefailingmyocytetoventricularfibrillation
AT alangarfinkel electrophysiologyofheartfailureusingarabbitmodelfromthefailingmyocytetoventricularfibrillation