The assessment of applicability of single-stage piston long-stroke low-speed compressors in low-temperature refrigeration machines
The work processes and integral characteristics of low-temperature ammonia single-stage piston longstroke low-speed compressors are considered. A method for calculating the actual working process of a stage of such a compressor is presented, taking into account such basic factors as the processes o...
Saved in:
| Main Authors: | , , |
|---|---|
| Format: | Article |
| Language: | English |
| Published: |
Omsk State Technical University, Federal State Autonomous Educational Institution of Higher Education
2024-10-01
|
| Series: | Омский научный вестник: Серия "Авиационно-ракетное и энергетическое машиностроение" |
| Subjects: | |
| Online Access: | https://www.omgtu.ru/general_information/media_omgtu/journal_of_omsk_research_journal/files/arhiv/2024/%D0%A2.8,%20%E2%84%963%20(%D0%90%D0%A0%D0%B8%D0%AD%D0%9C)/21-28%20%D0%AE%D1%88%D0%B0%20%D0%92.%20%D0%9B.,%20%D0%91%D1%83%D1%81%D0%B0%D1%80%D0%BE%D0%B2%20%D0%A1.%20%D0%A1.,%20%D0%9D%D0%B5%D0%B4%D0%BE%D0%B2%D0%B5%D0%BD%D1%87%D0%B0%D0%BD%D1%8B%D0%B9%20%D0%90.%20%D0%92..pdf |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| Summary: | The work processes and integral characteristics of low-temperature ammonia single-stage piston longstroke low-speed compressors are considered. A method for calculating the actual working process of
a stage of such a compressor is presented, taking into account such basic factors as the processes of
non-stationary heat transfer between the working fluid in the cylinder and the external cooling medium;
processes of flow of the working fluid through leaks in valves and in seals of the cylinder-piston group;
dynamics of motion of the shut-off valve body, etc. The flow coefficient, cooling coefficient, and
discharge temperature are considered as integral indicators. The following independent parameters are
considered: condensation and boiling temperatures, the main dimensions and parameters of the stage,
the temperature of the cooling medium and the heat transfer coefficient on the outer surface of the
cylinder, as well as the diameters of the suction and discharge valve seats.
A comparative analysis of the efficiency of the working process of the considered stage is performed
at a condensation temperature of 303 K and boiling temperatures in the range from 243 K to 173 K.
The relationship between the main dimensions and parameters of the stage, as well as the boiling point of ammonia with the integral characteristics of the compressor under consideration, has been studied.
The obtained results of the theoretical analysis make it possible to evaluate the possibility of replacing
multi-stage and cascade low-temperature refrigeration compressors with alternative single-stage ones
based on a low-speed, long-stroke stage as promising. |
|---|---|
| ISSN: | 2588-0373 2587-764X |