Diagnosis of Intraductal Biliary Lesions: Towards Greater Accuracy and Safety
Background/Aims: Pathological evaluation is crucial for diagnosing biliary lesions and determining appropriate treatment strategies. However, tissue sampling via the transpapillary route can be difficult. In this study, we aimed to assess the efficacy and safety of a novel tapered-tip sheath system...
Saved in:
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
Gastroenterology Council for Gut and Liver
2025-01-01
|
Series: | Gut and Liver |
Online Access: | http://gutnliver.org/journal/view.html?doi=10.5009/gnl240592 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1841536143121711104 |
---|---|
author | Sung Woo Ko Seung Bae Yoon |
author_facet | Sung Woo Ko Seung Bae Yoon |
author_sort | Sung Woo Ko |
collection | DOAJ |
description | Background/Aims: Pathological evaluation is crucial for diagnosing biliary lesions and determining appropriate treatment strategies. However, tissue sampling via the transpapillary route can be difficult. In this study, we aimed to assess the efficacy and safety of a novel tapered-tip sheath system for tissue sampling from biliary strictures. Methods: This single-center, randomized, parallel-group clinical trial included patients aged 20 to 85 years admitted to Kyoto University Hospital for biliary strictures. The patients were randomly assigned (1:1) to a new or conventional method group. The primary outcome was technical success of biopsy at the target bile duct using the assigned method, as determined in accordance with the intention-to-treat principle. Adverse events were assessed in all eligible patients. Results: Fifty-six patients were assessed for eligibility between September 2020 and March 2023; 50 patients were enrolled. The patients were randomly divided into the new (n=25) method group and the conventional (n=25) method group. Technical success was achieved in 96.0% (24/25) and 48.0% (12/25) of patients in the new and conventional method groups, respectively (risk ratio, 2.00; 95% confidence interval [CI], 1.32 to 3.03; risk difference, 48.0%; 95% CI, 27.0% to 69.0%; p<0.001). Adverse events occurred in 4.0% (1/25) and 36.0% (9/25) of patients in the new and conventional method groups, respectively (risk ratio, 0.11; 95% CI, 0.02 to 0.81; risk difference, -32.0%; 95% CI, -52.3% to -11.7%; p=0.005). Conclusions: The novel tapered-tip sheath system is a promising option for precisely and safely delivering biopsy forceps to target sites, thereby facilitating the diagnosis of biliary strictures. |
format | Article |
id | doaj-art-f05017ac26ca4d9fa85720dc91da0a2a |
institution | Kabale University |
issn | 1976-2283 |
language | English |
publishDate | 2025-01-01 |
publisher | Gastroenterology Council for Gut and Liver |
record_format | Article |
series | Gut and Liver |
spelling | doaj-art-f05017ac26ca4d9fa85720dc91da0a2a2025-01-15T00:51:13ZengGastroenterology Council for Gut and LiverGut and Liver1976-22832025-01-011916710.5009/gnl240592gnl240592Diagnosis of Intraductal Biliary Lesions: Towards Greater Accuracy and SafetySung Woo Ko0Seung Bae Yoon1Department of Internal Medicine, Eunpyeong St. Mary’s Hospital, College of Medicine, The Catholic University of Korea, Seoul, KoreaDepartment of Internal Medicine, Eunpyeong St. Mary’s Hospital, College of Medicine, The Catholic University of Korea, Seoul, KoreaBackground/Aims: Pathological evaluation is crucial for diagnosing biliary lesions and determining appropriate treatment strategies. However, tissue sampling via the transpapillary route can be difficult. In this study, we aimed to assess the efficacy and safety of a novel tapered-tip sheath system for tissue sampling from biliary strictures. Methods: This single-center, randomized, parallel-group clinical trial included patients aged 20 to 85 years admitted to Kyoto University Hospital for biliary strictures. The patients were randomly assigned (1:1) to a new or conventional method group. The primary outcome was technical success of biopsy at the target bile duct using the assigned method, as determined in accordance with the intention-to-treat principle. Adverse events were assessed in all eligible patients. Results: Fifty-six patients were assessed for eligibility between September 2020 and March 2023; 50 patients were enrolled. The patients were randomly divided into the new (n=25) method group and the conventional (n=25) method group. Technical success was achieved in 96.0% (24/25) and 48.0% (12/25) of patients in the new and conventional method groups, respectively (risk ratio, 2.00; 95% confidence interval [CI], 1.32 to 3.03; risk difference, 48.0%; 95% CI, 27.0% to 69.0%; p<0.001). Adverse events occurred in 4.0% (1/25) and 36.0% (9/25) of patients in the new and conventional method groups, respectively (risk ratio, 0.11; 95% CI, 0.02 to 0.81; risk difference, -32.0%; 95% CI, -52.3% to -11.7%; p=0.005). Conclusions: The novel tapered-tip sheath system is a promising option for precisely and safely delivering biopsy forceps to target sites, thereby facilitating the diagnosis of biliary strictures.http://gutnliver.org/journal/view.html?doi=10.5009/gnl240592 |
spellingShingle | Sung Woo Ko Seung Bae Yoon Diagnosis of Intraductal Biliary Lesions: Towards Greater Accuracy and Safety Gut and Liver |
title | Diagnosis of Intraductal Biliary Lesions: Towards Greater Accuracy and Safety |
title_full | Diagnosis of Intraductal Biliary Lesions: Towards Greater Accuracy and Safety |
title_fullStr | Diagnosis of Intraductal Biliary Lesions: Towards Greater Accuracy and Safety |
title_full_unstemmed | Diagnosis of Intraductal Biliary Lesions: Towards Greater Accuracy and Safety |
title_short | Diagnosis of Intraductal Biliary Lesions: Towards Greater Accuracy and Safety |
title_sort | diagnosis of intraductal biliary lesions towards greater accuracy and safety |
url | http://gutnliver.org/journal/view.html?doi=10.5009/gnl240592 |
work_keys_str_mv | AT sungwooko diagnosisofintraductalbiliarylesionstowardsgreateraccuracyandsafety AT seungbaeyoon diagnosisofintraductalbiliarylesionstowardsgreateraccuracyandsafety |