Ureteral Rupture Caused by Accidental Intubation of the Ureter with a Foley-Catheter during Ureterorenoscopy

We would like to present the case of a 64-year-old woman who underwent ureterorenoscopy and suffered an iatrogenic ureteral lesion due to an accidental intubation of the left ureter with a Foley-Catheter during the procedure. A Double-J-Stent was implanted into the damaged ureter, and 6 weeks later...

Full description

Saved in:
Bibliographic Details
Main Authors: F. Löcherbach, P. Grimsehl, A. Sauer, S. Wyler, M. Kwiatkowski
Format: Article
Language:English
Published: Wiley 2018-01-01
Series:Case Reports in Urology
Online Access:http://dx.doi.org/10.1155/2018/9738265
Tags: Add Tag
No Tags, Be the first to tag this record!