Ultrasonics absorption measurements of a liquid with backed transducer

An effect of backing of the transducer on the measured value of absorption of a liquid have been shown using shock excited system. The resulting deviation in the measured value of absorption from the accepted value has been observed to be large as 40 %, depending on the damping produced. A mechanism...

Full description

Saved in:
Bibliographic Details
Main Authors: V. N. BINDAL, T. K. SAKSENA, J. N. SOM
Format: Article
Language:English
Published: Institute of Fundamental Technological Research Polish Academy of Sciences 2015-07-01
Series:Archives of Acoustics
Online Access:https://acoustics.ippt.pan.pl/index.php/aa/article/view/3108
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850105101746700288
author V. N. BINDAL
T. K. SAKSENA
J. N. SOM
author_facet V. N. BINDAL
T. K. SAKSENA
J. N. SOM
author_sort V. N. BINDAL
collection DOAJ
description An effect of backing of the transducer on the measured value of absorption of a liquid have been shown using shock excited system. The resulting deviation in the measured value of absorption from the accepted value has been observed to be large as 40 %, depending on the damping produced. A mechanism to explain the observed variation of the measured value of absorption with backing has been put forward. Implication of the work in characterisation of ultrasonic probe have been discussed.
format Article
id doaj-art-eefe6425d22441e58dd0125054c0fa82
institution DOAJ
issn 0137-5075
2300-262X
language English
publishDate 2015-07-01
publisher Institute of Fundamental Technological Research Polish Academy of Sciences
record_format Article
series Archives of Acoustics
spelling doaj-art-eefe6425d22441e58dd0125054c0fa822025-08-20T02:39:11ZengInstitute of Fundamental Technological Research Polish Academy of SciencesArchives of Acoustics0137-50752300-262X2015-07-01111Ultrasonics absorption measurements of a liquid with backed transducerV. N. BINDAL0T. K. SAKSENA1J. N. SOM2National Physical Laboratory, New DelhiNational Physical Laboratory, New DelhiNational Physical Laboratory, New DelhiAn effect of backing of the transducer on the measured value of absorption of a liquid have been shown using shock excited system. The resulting deviation in the measured value of absorption from the accepted value has been observed to be large as 40 %, depending on the damping produced. A mechanism to explain the observed variation of the measured value of absorption with backing has been put forward. Implication of the work in characterisation of ultrasonic probe have been discussed.https://acoustics.ippt.pan.pl/index.php/aa/article/view/3108
spellingShingle V. N. BINDAL
T. K. SAKSENA
J. N. SOM
Ultrasonics absorption measurements of a liquid with backed transducer
Archives of Acoustics
title Ultrasonics absorption measurements of a liquid with backed transducer
title_full Ultrasonics absorption measurements of a liquid with backed transducer
title_fullStr Ultrasonics absorption measurements of a liquid with backed transducer
title_full_unstemmed Ultrasonics absorption measurements of a liquid with backed transducer
title_short Ultrasonics absorption measurements of a liquid with backed transducer
title_sort ultrasonics absorption measurements of a liquid with backed transducer
url https://acoustics.ippt.pan.pl/index.php/aa/article/view/3108
work_keys_str_mv AT vnbindal ultrasonicsabsorptionmeasurementsofaliquidwithbackedtransducer
AT tksaksena ultrasonicsabsorptionmeasurementsofaliquidwithbackedtransducer
AT jnsom ultrasonicsabsorptionmeasurementsofaliquidwithbackedtransducer