Study of moisture-induced temperature evolution in an engineered barrier system for a HLW repository

The present paper aims to assess the thermal behaviour of bentonite compaction's engineered barrier system (EBS) to designated dry density. An experiment was carried out on a small (centimetre scale) physical model of the EBS based on the design of the nuclear waste repository proposed by diffe...

Full description

Saved in:
Bibliographic Details
Main Authors: Manish Kumar Jha, Amit Jaiswal, A.K. Verma, Trilok Nath Singh
Format: Article
Language:English
Published: Elsevier 2025-12-01
Series:Results in Earth Sciences
Subjects:
Online Access:http://www.sciencedirect.com/science/article/pii/S2211714825000093
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1825206913196883968
author Manish Kumar Jha
Amit Jaiswal
A.K. Verma
Trilok Nath Singh
author_facet Manish Kumar Jha
Amit Jaiswal
A.K. Verma
Trilok Nath Singh
author_sort Manish Kumar Jha
collection DOAJ
description The present paper aims to assess the thermal behaviour of bentonite compaction's engineered barrier system (EBS) to designated dry density. An experiment was carried out on a small (centimetre scale) physical model of the EBS based on the design of the nuclear waste repository proposed by different studies. Temperature distribution within the physical model of the engineered barrier system has been recorded. Investigation of temperature evolution has been conducted in compacted bentonite at three different moisture contents: 10 %, 20 %, and 30 %. The temperature profile was recorded in the radial and lateral directions around the cylindrical heater with different moisture contents. A numerical model has also been developed to assess temperature evolution in radial and longitudinal directions at different moisture content in compacted bentonite. In the radial direction, the maximum temperature in the physical model at monitoring points reaches up to 71 °C 78°C and 79°C for moisture content of 10 %, 20 % and 30 %, respectively. Numerical simulation of the 3-dimensional model gives the maximum temperature of 61 °C, 68.6°C and 69.1°C, respectively, at a 10 %, 20 % and 30 % moisture level. Experimental results show that the maximum temperature developed in the longitudinal direction reaches up to 47°C, 53°C, and 56°C at monitoring points within bentonite having a moisture content of 10 %, 20 %, and 30 %, respectively. Temperatures obtained at a similar point through numerical simulation are 43°C, 47°C, and 53°C for moisture content of 10 %, 20 %, and 30 %, respectively. The difference between numerical and physical models varies up to 13 %. The study shows that the variation in moisture content significantly influences the temperature developed in the experimental setup of compacted bentonite.
format Article
id doaj-art-ee8c46ca409a4cbeb54bf9bd82348c55
institution Kabale University
issn 2211-7148
language English
publishDate 2025-12-01
publisher Elsevier
record_format Article
series Results in Earth Sciences
spelling doaj-art-ee8c46ca409a4cbeb54bf9bd82348c552025-02-07T04:47:29ZengElsevierResults in Earth Sciences2211-71482025-12-013100067Study of moisture-induced temperature evolution in an engineered barrier system for a HLW repositoryManish Kumar Jha0Amit Jaiswal1A.K. Verma2Trilok Nath Singh3University College of Engineering and Technology (UCET), Vinoba Bhave University, Hazaribagh, Jharkhand, IndiaDepartment of Civil and Environmental Engineering, Indian Institute of Technology Patna, Patna 801106, IndiaDepartment of Civil and Environmental Engineering, Indian Institute of Technology Patna, Patna 801106, India; Corresponding author.Department of Civil and Environmental Engineering, Indian Institute of Technology Patna, Patna 801106, IndiaThe present paper aims to assess the thermal behaviour of bentonite compaction's engineered barrier system (EBS) to designated dry density. An experiment was carried out on a small (centimetre scale) physical model of the EBS based on the design of the nuclear waste repository proposed by different studies. Temperature distribution within the physical model of the engineered barrier system has been recorded. Investigation of temperature evolution has been conducted in compacted bentonite at three different moisture contents: 10 %, 20 %, and 30 %. The temperature profile was recorded in the radial and lateral directions around the cylindrical heater with different moisture contents. A numerical model has also been developed to assess temperature evolution in radial and longitudinal directions at different moisture content in compacted bentonite. In the radial direction, the maximum temperature in the physical model at monitoring points reaches up to 71 °C 78°C and 79°C for moisture content of 10 %, 20 % and 30 %, respectively. Numerical simulation of the 3-dimensional model gives the maximum temperature of 61 °C, 68.6°C and 69.1°C, respectively, at a 10 %, 20 % and 30 % moisture level. Experimental results show that the maximum temperature developed in the longitudinal direction reaches up to 47°C, 53°C, and 56°C at monitoring points within bentonite having a moisture content of 10 %, 20 %, and 30 %, respectively. Temperatures obtained at a similar point through numerical simulation are 43°C, 47°C, and 53°C for moisture content of 10 %, 20 %, and 30 %, respectively. The difference between numerical and physical models varies up to 13 %. The study shows that the variation in moisture content significantly influences the temperature developed in the experimental setup of compacted bentonite.http://www.sciencedirect.com/science/article/pii/S2211714825000093EBSMoisture-induced temperature evolutionBentoniteNuclear waste repositoryHLWDry density
spellingShingle Manish Kumar Jha
Amit Jaiswal
A.K. Verma
Trilok Nath Singh
Study of moisture-induced temperature evolution in an engineered barrier system for a HLW repository
Results in Earth Sciences
EBS
Moisture-induced temperature evolution
Bentonite
Nuclear waste repository
HLW
Dry density
title Study of moisture-induced temperature evolution in an engineered barrier system for a HLW repository
title_full Study of moisture-induced temperature evolution in an engineered barrier system for a HLW repository
title_fullStr Study of moisture-induced temperature evolution in an engineered barrier system for a HLW repository
title_full_unstemmed Study of moisture-induced temperature evolution in an engineered barrier system for a HLW repository
title_short Study of moisture-induced temperature evolution in an engineered barrier system for a HLW repository
title_sort study of moisture induced temperature evolution in an engineered barrier system for a hlw repository
topic EBS
Moisture-induced temperature evolution
Bentonite
Nuclear waste repository
HLW
Dry density
url http://www.sciencedirect.com/science/article/pii/S2211714825000093
work_keys_str_mv AT manishkumarjha studyofmoistureinducedtemperatureevolutioninanengineeredbarriersystemforahlwrepository
AT amitjaiswal studyofmoistureinducedtemperatureevolutioninanengineeredbarriersystemforahlwrepository
AT akverma studyofmoistureinducedtemperatureevolutioninanengineeredbarriersystemforahlwrepository
AT triloknathsingh studyofmoistureinducedtemperatureevolutioninanengineeredbarriersystemforahlwrepository