THE RELIABILITY OF DETERMINING THE SHORT CIRCUIT ZONE OF THE LINES OF 6–35 kV

A method of increasing the reliability of determining the zone of short-circuit at the current step protection of the lines of 6–35 kV with unilateral power, aimed at improvement of their technical perfection, is presented in the paper. Having taken the relative simpleness of the current protection...

Full description

Saved in:
Bibliographic Details
Main Authors: F. А. Romaniuk, E. V. Buloichyk, O. A. Huryanchyk, V. S. Kachenya
Format: Article
Language:Russian
Published: Belarusian National Technical University 2018-01-01
Series:Известия высших учебных заведений и энергетических объединенний СНГ: Энергетика
Subjects:
Online Access:https://energy.bntu.by/jour/article/view/1140
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832543817465593856
author F. А. Romaniuk
E. V. Buloichyk
O. A. Huryanchyk
V. S. Kachenya
author_facet F. А. Romaniuk
E. V. Buloichyk
O. A. Huryanchyk
V. S. Kachenya
author_sort F. А. Romaniuk
collection DOAJ
description A method of increasing the reliability of determining the zone of short-circuit at the current step protection of the lines of 6–35 kV with unilateral power, aimed at improvement of their technical perfection, is presented in the paper. Having taken the relative simpleness of the current protection into account the authors consider the unilateral remote method of accounting the parameters of the emergency mode and the type of fault to be the most suitable for the implementation of the algorithm of its functioning as compared with the existing methods of fault location. The major factors affecting the accuracy of determining the short circuit zone based on the remote method are noted. With the use of the method of computational experiment the influence of the load currents and contact resistances of various levels on the magnitude and character of changes of errors of determination of the calculated distance of the point of fault from the protection installation location taking into account the errors of measuring transformers. It is demonstrated that in many cases of arc short circuit in a loaded line in order to define the zone of short-circuit with fair accuracy correction of the estimated distance to the fault as calculated by the parameters of the damaged loop (loops) is required. According to the results of numerical experiments corrective expressions on the basis of two relative asymmetry currents determined by the current values of the differences of the phase currents of the line for detecting a type of a short circuit have been obtained. The assessment of the efficiency of the proposed method has been performed. It is shown that the application of the proposed correction method makes it possible to increase the accuracy of fault zone detection. The dynamic properties of the proposed method applied to different modes of the line functioning have been studied. It is determined that in the worst case the definition of the fault zone for a maximum duration of 26 μsec is provided.
format Article
id doaj-art-ee4e5159c38e4d2c9d3b366f9e0b6f39
institution Kabale University
issn 1029-7448
2414-0341
language Russian
publishDate 2018-01-01
publisher Belarusian National Technical University
record_format Article
series Известия высших учебных заведений и энергетических объединенний СНГ: Энергетика
spelling doaj-art-ee4e5159c38e4d2c9d3b366f9e0b6f392025-02-03T11:34:15ZrusBelarusian National Technical UniversityИзвестия высших учебных заведений и энергетических объединенний СНГ: Энергетика1029-74482414-03412018-01-0161151410.21122/1029-7448-2018-61-1-5-141099THE RELIABILITY OF DETERMINING THE SHORT CIRCUIT ZONE OF THE LINES OF 6–35 kVF. А. Romaniuk0E. V. Buloichyk1O. A. Huryanchyk2V. S. Kachenya3Belarusian National Technical UniversityBelarusian National Technical UniversityBelarusian National Technical UniversityBelarusian National Technical UniversityA method of increasing the reliability of determining the zone of short-circuit at the current step protection of the lines of 6–35 kV with unilateral power, aimed at improvement of their technical perfection, is presented in the paper. Having taken the relative simpleness of the current protection into account the authors consider the unilateral remote method of accounting the parameters of the emergency mode and the type of fault to be the most suitable for the implementation of the algorithm of its functioning as compared with the existing methods of fault location. The major factors affecting the accuracy of determining the short circuit zone based on the remote method are noted. With the use of the method of computational experiment the influence of the load currents and contact resistances of various levels on the magnitude and character of changes of errors of determination of the calculated distance of the point of fault from the protection installation location taking into account the errors of measuring transformers. It is demonstrated that in many cases of arc short circuit in a loaded line in order to define the zone of short-circuit with fair accuracy correction of the estimated distance to the fault as calculated by the parameters of the damaged loop (loops) is required. According to the results of numerical experiments corrective expressions on the basis of two relative asymmetry currents determined by the current values of the differences of the phase currents of the line for detecting a type of a short circuit have been obtained. The assessment of the efficiency of the proposed method has been performed. It is shown that the application of the proposed correction method makes it possible to increase the accuracy of fault zone detection. The dynamic properties of the proposed method applied to different modes of the line functioning have been studied. It is determined that in the worst case the definition of the fault zone for a maximum duration of 26 μsec is provided.https://energy.bntu.by/jour/article/view/1140power linecurrent protectiontechnical excellencerelative asymmetryshort-circuit areacontact resistanceoperation speed
spellingShingle F. А. Romaniuk
E. V. Buloichyk
O. A. Huryanchyk
V. S. Kachenya
THE RELIABILITY OF DETERMINING THE SHORT CIRCUIT ZONE OF THE LINES OF 6–35 kV
Известия высших учебных заведений и энергетических объединенний СНГ: Энергетика
power line
current protection
technical excellence
relative asymmetry
short-circuit area
contact resistance
operation speed
title THE RELIABILITY OF DETERMINING THE SHORT CIRCUIT ZONE OF THE LINES OF 6–35 kV
title_full THE RELIABILITY OF DETERMINING THE SHORT CIRCUIT ZONE OF THE LINES OF 6–35 kV
title_fullStr THE RELIABILITY OF DETERMINING THE SHORT CIRCUIT ZONE OF THE LINES OF 6–35 kV
title_full_unstemmed THE RELIABILITY OF DETERMINING THE SHORT CIRCUIT ZONE OF THE LINES OF 6–35 kV
title_short THE RELIABILITY OF DETERMINING THE SHORT CIRCUIT ZONE OF THE LINES OF 6–35 kV
title_sort reliability of determining the short circuit zone of the lines of 6 35 kv
topic power line
current protection
technical excellence
relative asymmetry
short-circuit area
contact resistance
operation speed
url https://energy.bntu.by/jour/article/view/1140
work_keys_str_mv AT faromaniuk thereliabilityofdeterminingtheshortcircuitzoneofthelinesof635kv
AT evbuloichyk thereliabilityofdeterminingtheshortcircuitzoneofthelinesof635kv
AT oahuryanchyk thereliabilityofdeterminingtheshortcircuitzoneofthelinesof635kv
AT vskachenya thereliabilityofdeterminingtheshortcircuitzoneofthelinesof635kv
AT faromaniuk reliabilityofdeterminingtheshortcircuitzoneofthelinesof635kv
AT evbuloichyk reliabilityofdeterminingtheshortcircuitzoneofthelinesof635kv
AT oahuryanchyk reliabilityofdeterminingtheshortcircuitzoneofthelinesof635kv
AT vskachenya reliabilityofdeterminingtheshortcircuitzoneofthelinesof635kv