The aim of the study was to comparatively assess the efficacy of various diagnostic imaging modalities in detection of lung metastases of differentiated thyroid cancer. A retrospective analysis of the results of examination of 36 patients was carried out. Positron emission tomography/computed tomogr...

Full description

Saved in:
Bibliographic Details
Main Authors: Т. М. Geliashvili, A. V. Vazhenin, Е. B. Vasilyeva, N. G. Afanasyeva
Format: Article
Language:Russian
Published: Russian Academy of Sciences, Tomsk National Research Medical Center 2016-02-01
Series:Сибирский онкологический журнал
Subjects:
Online Access:https://www.siboncoj.ru/jour/article/view/203
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:The aim of the study was to comparatively assess the efficacy of various diagnostic imaging modalities in detection of lung metastases of differentiated thyroid cancer. A retrospective analysis of the results of examination of 36 patients was carried out. Positron emission tomography/computed tomography (PET/ CT) with [F-18] fluorodeoxyglucose (FDG) was found to have the highest sensitivity for detection of lung metastases of differentiated thyroid cancer (100 %) followed by CT of the chest (95.5 %) and whole body scintigraphy (WBS) with 131I (66.7 %).