Assessment of a simulation-based implementation method to support the introduction of a new invasive device: a prospective cross-over study

Study objective The introduction of new medical devices into care units, or their replacement by new devices, is not always accompanied by implementation strategies that enable healthcare professionals to use them safely. Simulation is a relevant tool for reproducing critical care clinical situation...

Full description

Saved in:
Bibliographic Details
Main Authors: Pierre Albaladejo, Julien Picard, Pierrick Bedouch, Claire Chapuis, Cordélia Salomez-Ihl
Format: Article
Language:English
Published: BMJ Publishing Group 2025-06-01
Series:BMJ Open Quality
Online Access:https://bmjopenquality.bmj.com/content/14/2/e003029.full
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850225639308656640
author Pierre Albaladejo
Julien Picard
Pierrick Bedouch
Claire Chapuis
Cordélia Salomez-Ihl
author_facet Pierre Albaladejo
Julien Picard
Pierrick Bedouch
Claire Chapuis
Cordélia Salomez-Ihl
author_sort Pierre Albaladejo
collection DOAJ
description Study objective The introduction of new medical devices into care units, or their replacement by new devices, is not always accompanied by implementation strategies that enable healthcare professionals to use them safely. Simulation is a relevant tool for reproducing critical care clinical situations without danger for the patients and providing training support. The aim of the study was to assess a simulation-based implementation method to accompany and reduce the risks associated with the deployment of a new invasive medical device in critical care units.Design Prospective mono-centric cross-over study.Setting In our hospital, the type of Invasive Arterial Blood Pressure Sensors (IABPS) for blood pressure (BP) monitoring and arterial sampling has been completely replaced by a new one with numerous differences. No specific training had been planned.Participants 66 intensive care unit (ICU) nurses from three ICUs with a total number of 39 beds were involved.Interventions The scenario and evaluation grid were designed by multi-disciplinary teams who received in-depth training on the new IABPS from the laboratory and the institution’s equipment specialists. Nurses in group A (GA) (n=33) started by using the IABPS on a simulation scenario and then received explanations on differences. Nurses in group B (GB) (n=33) received explanations and then used the IABPS on the simulation scenario. Nurses in GA and GB all had individual feedback on their errors at the end. Next, they listed the most important information they would give to a colleague if they had a few minutes to train him or her. They also completed an anonymous self-questionnaire to assess their satisfaction with the training and with the new IABPS.Main results The mean number of errors in the act of measuring BP and taking biological samples was statistically higher for GA, demonstrating the relevance of offering a training programme to support the deployment of a new device. The mean times to BP measurement and to collection were similar. Recommendations for asepsis of the sampling site were not followed. Recurrent errors were related to the ergonomics of the IABPS. Caregivers (n=55 questionnaires) appreciated the training and the new IABPS.Conclusions Simulation can be useful for both providing a training model and identifying the situations that would require dedicated training support. The simulation tool provided training and context to nurses before they use the new IAPBS in clinical practice. Simulation training has also led to a better understanding of the most common errors. Because of new IABPS widespread use, it was all the more important to prevent usage errors.
format Article
id doaj-art-edd49ecfbcbf4036ad4d96ec2deca313
institution OA Journals
issn 2399-6641
language English
publishDate 2025-06-01
publisher BMJ Publishing Group
record_format Article
series BMJ Open Quality
spelling doaj-art-edd49ecfbcbf4036ad4d96ec2deca3132025-08-20T02:05:18ZengBMJ Publishing GroupBMJ Open Quality2399-66412025-06-0114210.1136/bmjoq-2024-003029Assessment of a simulation-based implementation method to support the introduction of a new invasive device: a prospective cross-over studyPierre Albaladejo0Julien Picard1Pierrick Bedouch2Claire Chapuis3Cordélia Salomez-Ihl4Univ. Grenoble Alpes, CNRS, UMR 5525, VetAgro Sup, Grenoble INP, TIMC, Anaesthesiology and Intensive Care Department, CHU Grenoble Alpes, 38000 Grenoble, France, Grenoble, FranceUniv. Grenoble Alpes, CNRS, UMR 5525, VetAgro Sup, Grenoble INP, TIMC, Anaesthesiology and Intensive Care Department, CHU Grenoble Alpes, 38000 Grenoble, France, Grenoble, FranceUniv. Grenoble Alpes, CNRS, UMR 5525, VetAgro Sup, Grenoble INP, TIMC, Pharmacy Department, CHU Grenoble Alpes, 38000 Grenoble, France, Grenoble, FranceUniv. Grenoble Alpes, Pharmacy Department, CHU Grenoble Alpes, 38000 Grenoble, France, La Tronche, FranceUniv. Grenoble Alpes, CNRS, UMR 5525, VetAgro Sup, Grenoble INP, TIMC, Pharmacy Department, CHU Grenoble Alpes, 38000 Grenoble, France, Grenoble, FranceStudy objective The introduction of new medical devices into care units, or their replacement by new devices, is not always accompanied by implementation strategies that enable healthcare professionals to use them safely. Simulation is a relevant tool for reproducing critical care clinical situations without danger for the patients and providing training support. The aim of the study was to assess a simulation-based implementation method to accompany and reduce the risks associated with the deployment of a new invasive medical device in critical care units.Design Prospective mono-centric cross-over study.Setting In our hospital, the type of Invasive Arterial Blood Pressure Sensors (IABPS) for blood pressure (BP) monitoring and arterial sampling has been completely replaced by a new one with numerous differences. No specific training had been planned.Participants 66 intensive care unit (ICU) nurses from three ICUs with a total number of 39 beds were involved.Interventions The scenario and evaluation grid were designed by multi-disciplinary teams who received in-depth training on the new IABPS from the laboratory and the institution’s equipment specialists. Nurses in group A (GA) (n=33) started by using the IABPS on a simulation scenario and then received explanations on differences. Nurses in group B (GB) (n=33) received explanations and then used the IABPS on the simulation scenario. Nurses in GA and GB all had individual feedback on their errors at the end. Next, they listed the most important information they would give to a colleague if they had a few minutes to train him or her. They also completed an anonymous self-questionnaire to assess their satisfaction with the training and with the new IABPS.Main results The mean number of errors in the act of measuring BP and taking biological samples was statistically higher for GA, demonstrating the relevance of offering a training programme to support the deployment of a new device. The mean times to BP measurement and to collection were similar. Recommendations for asepsis of the sampling site were not followed. Recurrent errors were related to the ergonomics of the IABPS. Caregivers (n=55 questionnaires) appreciated the training and the new IABPS.Conclusions Simulation can be useful for both providing a training model and identifying the situations that would require dedicated training support. The simulation tool provided training and context to nurses before they use the new IAPBS in clinical practice. Simulation training has also led to a better understanding of the most common errors. Because of new IABPS widespread use, it was all the more important to prevent usage errors.https://bmjopenquality.bmj.com/content/14/2/e003029.full
spellingShingle Pierre Albaladejo
Julien Picard
Pierrick Bedouch
Claire Chapuis
Cordélia Salomez-Ihl
Assessment of a simulation-based implementation method to support the introduction of a new invasive device: a prospective cross-over study
BMJ Open Quality
title Assessment of a simulation-based implementation method to support the introduction of a new invasive device: a prospective cross-over study
title_full Assessment of a simulation-based implementation method to support the introduction of a new invasive device: a prospective cross-over study
title_fullStr Assessment of a simulation-based implementation method to support the introduction of a new invasive device: a prospective cross-over study
title_full_unstemmed Assessment of a simulation-based implementation method to support the introduction of a new invasive device: a prospective cross-over study
title_short Assessment of a simulation-based implementation method to support the introduction of a new invasive device: a prospective cross-over study
title_sort assessment of a simulation based implementation method to support the introduction of a new invasive device a prospective cross over study
url https://bmjopenquality.bmj.com/content/14/2/e003029.full
work_keys_str_mv AT pierrealbaladejo assessmentofasimulationbasedimplementationmethodtosupporttheintroductionofanewinvasivedeviceaprospectivecrossoverstudy
AT julienpicard assessmentofasimulationbasedimplementationmethodtosupporttheintroductionofanewinvasivedeviceaprospectivecrossoverstudy
AT pierrickbedouch assessmentofasimulationbasedimplementationmethodtosupporttheintroductionofanewinvasivedeviceaprospectivecrossoverstudy
AT clairechapuis assessmentofasimulationbasedimplementationmethodtosupporttheintroductionofanewinvasivedeviceaprospectivecrossoverstudy
AT cordeliasalomezihl assessmentofasimulationbasedimplementationmethodtosupporttheintroductionofanewinvasivedeviceaprospectivecrossoverstudy