Practical challenges of the concept of using Dual-energy X-ray absorptiometry in the management of pediatric distal radius fractures

Distal radius fractures are the most common pediatric injuries with increasing numbers in the recent years. The diagnosis of distal radius fracture is usually based on history taking, physical examination, and plain wrist radiographies. However, the radiation risk of plain X-ray imaging is its major...

Full description

Saved in:
Bibliographic Details
Main Author: Alireza Mobasseri
Format: Article
Language:English
Published: Elsevier 2025-06-01
Series:Journal of Orthopaedic Reports
Online Access:http://www.sciencedirect.com/science/article/pii/S2773157X24002200
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1841544025250725888
author Alireza Mobasseri
author_facet Alireza Mobasseri
author_sort Alireza Mobasseri
collection DOAJ
description Distal radius fractures are the most common pediatric injuries with increasing numbers in the recent years. The diagnosis of distal radius fracture is usually based on history taking, physical examination, and plain wrist radiographies. However, the radiation risk of plain X-ray imaging is its major drawback when obtaining exposures in children in their growing age. During the last few years, Dual-energy X-ray absorptiometry (DXA) scanners became more available with a highly increased resolution. This has given the opportunity for its clinical use in trauma settings. DXA scan has been associated with lower radiation exposures compared with plain radiography. Here we have reviewed possible practical challenges of its use in the management of pediatric distal radius fractures. The radiation dosage could reduce dramatically if a modified DXA scan is used in emergency setting for the diagnosis. A portable DXA machine is needed in the orthopedic operating room for evaluation of the fracture reduction and inspection of pin trajectory. Software and hardware modifications are also needed for DXA machine when it is used for follow-up visits. These changes should enhance image resolution in the presence of pin and cast. The modified DXA machine would probably result in 20–80 times less radiation exposure during the management of a routine pediatric distal radius fracture.
format Article
id doaj-art-ecc4482cd5f744b99bb234c0ab311fa3
institution Kabale University
issn 2773-157X
language English
publishDate 2025-06-01
publisher Elsevier
record_format Article
series Journal of Orthopaedic Reports
spelling doaj-art-ecc4482cd5f744b99bb234c0ab311fa32025-01-13T04:19:21ZengElsevierJournal of Orthopaedic Reports2773-157X2025-06-0142100525Practical challenges of the concept of using Dual-energy X-ray absorptiometry in the management of pediatric distal radius fracturesAlireza Mobasseri0PTB Company, Poonak sq, Tehran, IranDistal radius fractures are the most common pediatric injuries with increasing numbers in the recent years. The diagnosis of distal radius fracture is usually based on history taking, physical examination, and plain wrist radiographies. However, the radiation risk of plain X-ray imaging is its major drawback when obtaining exposures in children in their growing age. During the last few years, Dual-energy X-ray absorptiometry (DXA) scanners became more available with a highly increased resolution. This has given the opportunity for its clinical use in trauma settings. DXA scan has been associated with lower radiation exposures compared with plain radiography. Here we have reviewed possible practical challenges of its use in the management of pediatric distal radius fractures. The radiation dosage could reduce dramatically if a modified DXA scan is used in emergency setting for the diagnosis. A portable DXA machine is needed in the orthopedic operating room for evaluation of the fracture reduction and inspection of pin trajectory. Software and hardware modifications are also needed for DXA machine when it is used for follow-up visits. These changes should enhance image resolution in the presence of pin and cast. The modified DXA machine would probably result in 20–80 times less radiation exposure during the management of a routine pediatric distal radius fracture.http://www.sciencedirect.com/science/article/pii/S2773157X24002200
spellingShingle Alireza Mobasseri
Practical challenges of the concept of using Dual-energy X-ray absorptiometry in the management of pediatric distal radius fractures
Journal of Orthopaedic Reports
title Practical challenges of the concept of using Dual-energy X-ray absorptiometry in the management of pediatric distal radius fractures
title_full Practical challenges of the concept of using Dual-energy X-ray absorptiometry in the management of pediatric distal radius fractures
title_fullStr Practical challenges of the concept of using Dual-energy X-ray absorptiometry in the management of pediatric distal radius fractures
title_full_unstemmed Practical challenges of the concept of using Dual-energy X-ray absorptiometry in the management of pediatric distal radius fractures
title_short Practical challenges of the concept of using Dual-energy X-ray absorptiometry in the management of pediatric distal radius fractures
title_sort practical challenges of the concept of using dual energy x ray absorptiometry in the management of pediatric distal radius fractures
url http://www.sciencedirect.com/science/article/pii/S2773157X24002200
work_keys_str_mv AT alirezamobasseri practicalchallengesoftheconceptofusingdualenergyxrayabsorptiometryinthemanagementofpediatricdistalradiusfractures