THE EFFECT OF PACKAGING TYPE AND STORAGE TEMPERATURE ON THE SHORT TERM STABILITY OF ELECTROLYTIC CONDUCTIVITY REFERENCE MATERIALS
In this work, monitoring the effect of packaging type and storage temperature on the short term stability of calibration standard solution KCl 1 M were conducted. The KCl 1M were packaged in two types of packaging i.e., high-density polyethylene (HDPE) and glass bottle. The effects of packaging typ...
Saved in:
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Alma Mater Publishing House "Vasile Alecsandri" University of Bacau
2021-06-01
|
Series: | Journal of Engineering Studies and Research |
Subjects: | |
Online Access: | https://jesr.ub.ro/index.php/1/article/view/251 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1823858375184613376 |
---|---|
author | AYU HINDAYANI OMAN ZUAS NURYATINI HAMIM |
author_facet | AYU HINDAYANI OMAN ZUAS NURYATINI HAMIM |
author_sort | AYU HINDAYANI |
collection | DOAJ |
description |
In this work, monitoring the effect of packaging type and storage temperature on the short term stability of calibration standard solution KCl 1 M were conducted. The KCl 1M were packaged in two types of packaging i.e., high-density polyethylene (HDPE) and glass bottle. The effects of packaging type and storage temperature were monitored for four weeks at 25 °C and 40 °C. The conductivity values of KCl 1 M in the HDPE and glass bottle were 111.61 mS/cm and 111.62 mS/cm, respectively. The results indicated that the KCl 1M solution at 25 °C in both HDPE and glass bottle were found to be good in short term stability and there was no significant different between the two packaging types. At temperature of 40 °C, however, short term stability of the KCl 1 M in a glass bottle was better than the HDPE bottle.
|
format | Article |
id | doaj-art-eca542182a894141a58dfd3d85228fff |
institution | Kabale University |
issn | 2068-7559 2344-4932 |
language | English |
publishDate | 2021-06-01 |
publisher | Alma Mater Publishing House "Vasile Alecsandri" University of Bacau |
record_format | Article |
series | Journal of Engineering Studies and Research |
spelling | doaj-art-eca542182a894141a58dfd3d85228fff2025-02-11T11:40:21ZengAlma Mater Publishing House "Vasile Alecsandri" University of BacauJournal of Engineering Studies and Research2068-75592344-49322021-06-0127110.29081/jesr.v27i1.251THE EFFECT OF PACKAGING TYPE AND STORAGE TEMPERATURE ON THE SHORT TERM STABILITY OF ELECTROLYTIC CONDUCTIVITY REFERENCE MATERIALSAYU HINDAYANIOMAN ZUASNURYATINI HAMIM In this work, monitoring the effect of packaging type and storage temperature on the short term stability of calibration standard solution KCl 1 M were conducted. The KCl 1M were packaged in two types of packaging i.e., high-density polyethylene (HDPE) and glass bottle. The effects of packaging type and storage temperature were monitored for four weeks at 25 °C and 40 °C. The conductivity values of KCl 1 M in the HDPE and glass bottle were 111.61 mS/cm and 111.62 mS/cm, respectively. The results indicated that the KCl 1M solution at 25 °C in both HDPE and glass bottle were found to be good in short term stability and there was no significant different between the two packaging types. At temperature of 40 °C, however, short term stability of the KCl 1 M in a glass bottle was better than the HDPE bottle. https://jesr.ub.ro/index.php/1/article/view/251chemical metrology, calibration, homogeneity, primary standard solution, traceability. |
spellingShingle | AYU HINDAYANI OMAN ZUAS NURYATINI HAMIM THE EFFECT OF PACKAGING TYPE AND STORAGE TEMPERATURE ON THE SHORT TERM STABILITY OF ELECTROLYTIC CONDUCTIVITY REFERENCE MATERIALS Journal of Engineering Studies and Research chemical metrology, calibration, homogeneity, primary standard solution, traceability. |
title | THE EFFECT OF PACKAGING TYPE AND STORAGE TEMPERATURE ON THE SHORT TERM STABILITY OF ELECTROLYTIC CONDUCTIVITY REFERENCE MATERIALS |
title_full | THE EFFECT OF PACKAGING TYPE AND STORAGE TEMPERATURE ON THE SHORT TERM STABILITY OF ELECTROLYTIC CONDUCTIVITY REFERENCE MATERIALS |
title_fullStr | THE EFFECT OF PACKAGING TYPE AND STORAGE TEMPERATURE ON THE SHORT TERM STABILITY OF ELECTROLYTIC CONDUCTIVITY REFERENCE MATERIALS |
title_full_unstemmed | THE EFFECT OF PACKAGING TYPE AND STORAGE TEMPERATURE ON THE SHORT TERM STABILITY OF ELECTROLYTIC CONDUCTIVITY REFERENCE MATERIALS |
title_short | THE EFFECT OF PACKAGING TYPE AND STORAGE TEMPERATURE ON THE SHORT TERM STABILITY OF ELECTROLYTIC CONDUCTIVITY REFERENCE MATERIALS |
title_sort | effect of packaging type and storage temperature on the short term stability of electrolytic conductivity reference materials |
topic | chemical metrology, calibration, homogeneity, primary standard solution, traceability. |
url | https://jesr.ub.ro/index.php/1/article/view/251 |
work_keys_str_mv | AT ayuhindayani theeffectofpackagingtypeandstoragetemperatureontheshorttermstabilityofelectrolyticconductivityreferencematerials AT omanzuas theeffectofpackagingtypeandstoragetemperatureontheshorttermstabilityofelectrolyticconductivityreferencematerials AT nuryatinihamim theeffectofpackagingtypeandstoragetemperatureontheshorttermstabilityofelectrolyticconductivityreferencematerials AT ayuhindayani effectofpackagingtypeandstoragetemperatureontheshorttermstabilityofelectrolyticconductivityreferencematerials AT omanzuas effectofpackagingtypeandstoragetemperatureontheshorttermstabilityofelectrolyticconductivityreferencematerials AT nuryatinihamim effectofpackagingtypeandstoragetemperatureontheshorttermstabilityofelectrolyticconductivityreferencematerials |